Pecron E1500 LFP Manuale utente

E1500
100V~120V-15A(MAX)
AC INPUT AC OUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DC INPUT
Please read the user manual thoroughly before using
USER MANUAL
100V~120V-50Hz/60Hz

E1500
100V~120V-15A(MAX)
AC INPUT AC OUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DC INPUT
①
④
⑦
⑩
⑬
LCD Display
Fuse
Wireless Charger
DC12V XT60 Output
USB-A/USB-C Ports
②
⑤
⑧
⑪
⑭
DC 32V~95V Charging Port
AC 100V~120V Input
DC 12V/USB/ Wireless Switch
DC12V Auxiliary Output
Battery Expansion Port
③
⑥
⑨
⑫
DC 12V~18V Charging Port
AC 100V~120V Output
AC 100V~120V Switch
DC12V(5525)Output
FUNCTION INTRODUCTION
①
②
③
④
⑤
⑥
⑭
⑧
⑨
⑩
⑪
⑬
⑦
⑫
3 5
4
2 1

Battery Type
LiFePO4 Battery
Retain 80%+
Original Capacity
At 3500 Cycles
Temperature
0℃~45℃/32°F~113°F
(Charging)
-20℃~45℃/-4°F~113°F
(Discharging)
Dimension
L14.8*W9.3*H12 in
L377*W237*H305
mm
Capacity
1536Wh
(51.2V30Ah)
Protections
Over-Voltage,
Overheat,
Overload,
Short-Circuit,
Self-Recovery
Charging Time
0.9H to 80%
1.8H to 100%
Net Weight
Around 39.7lb
Around 18Kg
E1500
210V~230V-10A(最大)
AC 输入 AC 输出 220V-2200W
DC 输出
12V-30A(最大)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(最大) 12V~18V
100W(最大)
DC 充电
AC Out *3
Pure sine wave
100V~120V
Rated 2200W
USB-A *4
(5V,9V,12V,
Max 18W)*4
(5V,9V,12V,
Max 18W)*1
(5V,9V,12V,20V,
Max 100W)*1
USB-C *2
DC 12V-10A
Cigar Port *1
Max 15W
Wireless Charger *1
DC 12V-30A
XT60 Output *1
DC 12V-5A
DC 5525 Output *1
SPECIFICATIONS
OUTPUT SPECS
UPS SPECS
AC 100V~120V
Max 15A
CASCADE FUNCTION
Cascadable
EP3000-48V
Port For Cascade *1
INPUT SPECS
DC Charging
(32V~95V)
Max 700W
Max 15A
5521 *1
DC Charging
(12V~18V)
Max 100W
Max 7A
GX16MF *1
AC 100V~120V
1400W
AC INLET *1
3 5
4
2 1

E1500
100V~120V-15A(MAX)
ACINPUT ACOUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DC INPUT
HOW TO USE THE E1500 LFP
press and hold to turn on / off DC / USB / Wireless Charger
press and hold to turn on / off AC
LCD SMART DISPLAY
Time Indicator
DC Out
Temperature Alarm
Battery Soc(%)
Voltage(V)
AC Overload Alarm
Charge Indicator
Discharge Indicator
Net Input/Output Wattage
AC Out
AC Input Wattage(W)/Voltage(V)
PF Value/Remaining Charging/
Discharging Time(Hrs)
UPS
Wireless connection
(Please turn off the AC function if there is no AC load on the unit)
AC Overload Alarm Icon
E1500 LFP can power most devices with power consumption
less than 2200 watts.
If your devices exceed 2200W, The AC overload alarm indicator
will flash, The unit will stop supplying power.
Temperature Alarm Icon
The operating temperature range of E1500 LFP is -20~45°C. If it
outputs high power in a hot conditions for a long time, the high
temperature alarm icon will flash, indicating that the inverter is
overheated, and the AC output will be turned off.
Wireless function prompt
When the power station is connected to the network via WIFI,
this icon will be always on to indicate.
UPS function prompt
When the power station has AC input and the AC output is
turned on, the UPS will be turned on, and the UPS icon will
always be on to remind.
DC
AC
AC
DC

PACKING LIST
RECHARGE TIME
SOLAR CHARGE TIME
Recommended
MC4 Solar Charging Cable
PECRON solar panel
The solar charging time depends on weather conditions. E1500 LFP has a built-in MPPT charge controller that
supports 32~95V, 15A PV charging up to 700W.
200W
9~10 Hours
Recommended
400W
5~6 Hours
Recommended
600W
3.5~4 Hours
Anderson Solar
Charging Cable*1
PECRON E1500 LFP*1 AC Charing Cable*1 MC4 Solar Charging
Cable(LSMC4-5GX16)*1
Car Charging
Cable*1
12V Alligator Clips*1
Around 1.8Hours
Car Charger
Around 18HoursAround 1.8Hours
Wall Charger Electric Generator
When charging with the engine, the instability of the voltage and frequency of the generator may damage the machine!
E1500
100V~120V-15A(MAX)
ACINPUT ACOUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DCINPUT

UPS FUNCTION
The E1500 LFP supports UPS function. It can provide the loads(such as computers, data centers, telecommunication equipment)
near-instantaneous(within 8~20ms) protection from unexpected power interruptions of the main power supply.
Note: Not applicable to specific applications that need transfer time under 8ms, such as servers and workstations.
This UPS function only support protection for loads under 1800W(120V), we recommend that you only connect one
device at a time to avoid overload and thus result in protection failure.
PECRON is not responsible for any devices damege or loss of data resulting from failing to follow the instructions.
1:After power on, long press the AC + DC switch,
see the battery symbol flashing, enter the setting
item;
2:See item 001 setting, which is the AC output frequency,
short press DC, switch 50/60Hz; short press AC, enter
the next item;
HOW TO ADJUST THE AC OUTPUT FREQUENCY VOLTAGE
AND NO-POWER AUTOMATIC SHUTDOWN TIME OF E1500 LFP.
E1500
100V~120V-15A(MAX)
ACINPUT ACOUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DCINPUT

3:Enter item 002 setting, which is AC output voltage,
short press AC, switch voltage; short press AC, enter
the next item;
4:Enter 003 item settings, the default value is OFF, this
is the automatic shutdown setting of the machine
without output, short press DC, cycle switching
settings; short press AC, enter the next item;
5:Enter 004 item settings, this is the WIFI reset command,
the default is not reset, short press DC, the screen
display reads rst, indicating reset;
6:Press and hold AC to exit the setting, EEP is displayed
when exiting, which means the setting is successful.

Two PECRON EP3000-48V power packs can be
cascaded using PECRON's dedicated MJ32 socket.
Do not expand with any battery modules other
than the PECRON's, this could damage the unit!
After cascade completion, the display will
show the percentage of the sum of E1500 LFP
and EP3000-48V.
USING SOLAR PANELS TO CHARGE THE E1500 LFP
1. DC5521 Charging Port: PV/DC 12V~18V, 100W maximum; VOC(open circuit voltage) of solar panel must be less than
25V;
2. GX16MF-5 Charging Port: PV(operating voltage) range 32V~95V, 700W maximum; VOC(open circuit voltage) of solar
panel/array must be less than 95V, otherwise, it will damage the unit! Do not wire more than two 36V solar panels in
series, or more than four 18V solar panels in series.
(18V/36V stands for Vmp, the operating voltage, of the solar panel)
3. If you have any questions, feel free to contact us:[email protected]
EXPANDABLE BATTERY
E1500
100V~120V-15A(MAX)
ACINPUT AC OUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DCINPUT
3 5
4
2 1
E1500
100V~120V-15A(MAX)
ACINPUT ACOUTPUT-2200W
DC 输出
12V-30A(MAX)
12V-5A 12V-10A
12V-10A
USB
100W 18W 18W
18W 18W 18W
32V~95V
700W(MAX) 12V~18V
100W(MAX)
DCINPUT
DC5521 Charging Port:
PV12V~18V-100W Maximum Input
GX16MF-5 Charging Port:
PV32V~95V-700W Maximum Input

USING SOLAR PANELS TO CHARGE THE E1500 LFP
Charging the E1500 LFP with one solar panel
MC4 Solar Charging Cable*1
MC4 Solar Charging Cable*1
※ This sentence recommends using PECRON solar panels for the best user experience. The VOC of a single solar panel should
be less than 95V, and the VMP should be greater than 32V.
Use two solar panels in series to charge the E1500 LFP
※ This sentence recommends using PECRON solar panels for the best user experience. The VOC of a single solar panel should
be less than 48V, and the VMP should be greater than 16V.

USING SOLAR PANELS TO CHARGE THE E1500 LFP
MC4 Solar Charging Cable*1
Y Branch MC4 Charging Cable(+)*1
Y Branch MC4 Charging Cable(-)*1
(NOTE:This parallel charging cable sold separately)
※ This sentence recommends using PECRON solar panels for the best user experience. The VOC of a single solar panel should
be less than 95V, and the VMP should be greater than 32V.
Use three solar panels in parallel to charge the E1500 LFP
(Recommended to use solar panels of the same specification model to obtain the best power.)
Indice