This boiler is shipped with a Flex-L International Vent
Terminal carton, and a Flex-L International Venting
Components Kit. The following components from
these two cartons must be used in the installation of
this boiler:
•CeraFlex Oil Vent Terminal
•CeraFlex Vent Pipe
•CeraFlex Appliance Adapter
•CeraFlexTerminal Adapter
•CeraFlex Sealant
This Oil-Fired Unit Shall be Connected to a Direct Vent
System, to Assure Safe Proper Operation of the Unit.
F__I |vJ_b._lI _.'t'I..lI_LVjI IO!--'IILIlIZlI[e]_
I. Determine vent terminallocation:
a. Vent length must be between 5' and 20' long. See
paragraph 3 and Figure 5 for air intake
requirements.
b. No clearance is required between vent terminal
and combustible construction.
c. Vent terminal extends 12" beyond outside wall
surface and at least 16" beyond inside wall
surface. See Figure 5.
d. Provide 3' clearance above any forced air inlet
within 10'.
e. Provide 4' clearance below, 4' beside, or ]' above
any door, window, or gravity air inlet into any
building.
Provide 1' clearance between bottom of vent
terminal and ground level or between bottom of
vent terminal and normal snow lines.
g,
h,
i,
J,
Provide 4' horizontal clearance from, and in no
case above or below, unless a 4' horizontal
clearance is maintained, from electric meters, gas
meters, gas regulators, and gas relief equipment.
Provide 5*clearance to the vent outlet of a fuel
oil supply tank.
Provide 1' clearance to the soffit of the roof and
3' clearance to an inside corner of an L-shaped
building.
Do not locate vent terminal over public walkways
where condensate could create a nuisance or
hazard.
k. When adjacent to a public walkway, locate vent
terminal at least 7' above grade.
2. Use FIex-L International Inc. 4" diameter CeraFlex
Vent Pipe.
Table 1
WALL
]]41CKNESS
1"
2"
3"
4-"
5"
6" TO 14"
DIM.
A
21"
20"
19"
18"
-VENT PIPE MATERIAL: FLEX L INTERNATIONAL iNC.
4"¢ CERAFLEX VENT PIPE. LENGTH: 5' TO 20'
17" 12 !/2"_,_
16"
OUTER WALL_
PLATE
EXHAUST
ABOVE GROUND
OR NORMALLY
EXPECTEDSNOW
ACCUMULATIONLEVEL
TERMIN
_INNER
WALL
PLATE
INTAKE
CLAMP
(BY INSTALLER)
(SLOPING DOWN
TOWARDS TERMINAL)
MIN. 1/4" SLOPE/FOOT
:E ADAPTER
WITH TEST PORT
_AIR INTAKE MATERIAL: ALUMINUM
FLEX (SHOWN) 5' TO 30' OR GALVANIZED
SMOKE PIPE 5' TO 40' EQUIVALENT
,jrWV-DV INTAKE CLAMP
(BY INSTALLER)
AIR ADAPTER
(RIELLO ONLY)
Figure 5: Venting
7