Pegasus Pneumatic Istruzioni operative

Pegasus Pneumac User & Installaon Instrucons
User Instrucons:
Whirlpool - Push the on/o buon once
to acvate the whirlpool and again to
deacvate (pictured above).
Air Control - Whilst the whirlpool is running
you can turn the air control to increase the
air ow to the jets - the more air the greater
the pressure.
Turbo Whirlpool - If you have a turbo
whirlpool the air control will be replaced
by a second on/o buon. Push this buon
whilst the whirlpool is in operaon to
acvate the ‘turbo boost’.
Hydro Whirplool - Hydro systems are
controlled by 2 on/o buons and a diverter
valve (pictured above). Air from the blower
can be directed to the whirlpool system using
the diverter valve giving a ‘turbo-boosted’
massage.
Push the on/o buons once to acvate
each feature and again to deacvate them.
Once both the whirlpool and the airpool are
in operaon the diverter valve can be turned
to chose between 3 massage opons; turbo
whirlpool only, spa only or both at the same
me.
System Blow Dry - This feature is only
available on turbo and hydro systems.
Once you have emped your whirlpool bath
acvate the blower for a couple of minutes
to dry the pipework.
Cleansing - For cleansing of your whirlpool
system we recommend regular use of our
whirlbath cleanser and saniser tablets.
Installaon Instrucons:
IMPORTANT - Do not use a knife to remove
the wrapping. This bath has been factory
ed with a quality whirlpool system. Once
ed the whole system has then been water
& electrically tested, quality inspected and
then wrapped to ensure that it arrives with
you in perfect working order.
It is the responsibility of the contractor/
purchaser to ensure that this bath is installed
only by a qualied Plumber & a qualied
Electrician. All electrical connecons
must comply with the current edion of
I.E.E. Regulaons. Aer connecon the
appropriate compleon cercate must be
presented to the end user in accordance
with I.E.E. Regulaons.
WARNING - If damage is caused to the
system due to mishandling or incorrect
installaon, Pegasus Whirlpool Baths (UK)
Ltd reserve the right to charge for any repair
work needed! Our Callout charge is £75.00
plus VAT and will be charged to the customer
for all callouts whether the fault lies with the
customer or the installers.
Apology to installers - This whirlpool
system has been ed to this bath so as to
allow as litle water as possible to remain in
the pipework aer use. With some baths
(especially corner baths) our best t policy
can occasionally mean a pump posion or
awkwardly placed pipework which will make
life dicult for the installer and increase the
normal installaon me. Our policy on water
retenon is, that is is beer for the installer
to “suer” for a couple of hours, than for the
end-user to suer for years - If you are one of
the few installers to “suer”, please accept
our apologies.
The quality of this nished product is now
in your hands. If you would like to discuss
the opons available, please ring us on our
Duty Technical Support Engineer on
01633 244555.
Plumbers Instrucons:
xDO NOT li or manoeuvre the bath by the
whirlpool pipework.
xDO NOT remove the protecve tape from
the controls on the rim of the bath unl all
plastering and groung has been completed.
Grout dust has been known to cement the
air control solid.
x DO NOT remove any electrical es on the
pipework - they are there for a purpose. Ties
that have not had their ends clipped can be
removed.
x DO NOT allow the electrician to install the
E.L.C.B. under the bath - it makes it awkward
for future access.
x DO NOT allow anyone to dry run the
pump. i.e. do not run the pump without
water in the system. Water acts as a coolant
for the pump impellor and casing without
which costly damage will occur.
● ACCESS must be provided to the pump,
control box and waste.
● Assemble the bath legs etc as per the
manufacturers instrucons taking care if
the bath has to be turned upside down.
Occasionally we will temporarily t the
legs to the bath when ng the whirlpool
system. If the legs are subsequently le on
the bath it is sll the plumbers responsibility
to check that all screws and brackets are in
place and secure.
Head Oce: 61-62 Lower Dock Street, Newport, South Wales NP20 1EF
Telephone: (01633) 244555
Facsimile: (01633) 244881
Email: sales@pegasuswhirlpoolbaths.co.uk
Internet: hp://www. pegasuswhirlpoolbaths.co.uk
Connued overleaf....

Pegasus Pneumac User & Installaon Instrucons
● Fit the pump bracket support leg and
adjust to correct height.
● Adjust feet to the required height for the
bath panel and slide the bath into posion.
● Set the bath level and pret the bath
into the desired posion. Check that the
pump is within the connes of the bath. If
the pump exceeds the connes of the bath
it will be necessary to chase out the wall
to accommodate the pump. This should be
done before the bath is nally ed.
● Ensure that all hot water pipes are clear
of the whirlpool pipework - If necessary
remove bath and re-make the hot water
pipes keeping the blow torch away from t h e
bath and whirlpool pipework.
● When the bath is level in the required
posion, and before nal xing takes
place, temporarily connect the waste and
water feeds, ll the bath with warm water
to the level of the overow and operate
the whirlpool system under pressure for
a period of 20 minutes. During this me
all joints should be checked to ensure that
they have not been damged or weakened in
transit. Leave the bath standing with water
in it for a further 20 minutes and recheck the
joints. Carry out procedures detailed in the
commissioning checklist opposite.
● Please note that we will not accept
responsibility for removing the bath to
repair any leaks which are discovered aer
the bath has been nally xed and led in
place.
● The bath is now ready for an electrician to
make the nal electrical connecon.
Electricians Instrucons:
● The whirlpool system must be protected.
In most circumstances the system may be
connected into the 13 amp ring main, it does
not need a separate supply from the main
board. This connecon should be made via
a 13 amp fused spur, located outside of the
bathroom.
● It is not adviseable to locate the E.L.C.B./
R.C.C.B/ under the bath, it is awkward for
access at a later date.
● DO NOT remove the protecve tape from
the controls on the rim of the bath unl all
plastering and groung has been completed.
Grout dust has been known to cement the
air control solid.
● DO NOT remove any electrical es on
the whirlpool pipework - they are there for
a purpose. If you wish to relocate any of
the electrical boxes for ease of access aer
installaon please make sure that wires are
not stretched.
● DO NOT allow anyone to dry run the pump.
i.e.do not run the pump without water in the
system. Water acts as a coolant for the pump
impellor and casing without which costly
damage will occur.
● If it is necessary to remove the pump
from the bath ensure that when it is
reinstalled that the rubber seals are in place.
● The pump and controls have been prewired
for ease of installaon - please double check
that all connecons have travelled well and
are to your sasfacon.
● Connect the unassigned mains cable
from the control box through the E.L.C.B. to
the 13A fused spur.
● Connect the earth bonding as required by
I.E.E. Regulaons.
● In the absence of a plumber it is advisable
that the electrician carries out the inial
commissioning procedures - see below.
● The electrical installaon should now
be inspected in accordance with the
latest edion of I.E.E. regulaons and the
Compleon Cercate signed and handed to
the customer.
Safety Informaon:
SOP Number:_________________________
Pump - Serial No: ______________________
Pump Amps: _________________________
In-Line Heater Amps: ___________________
Z:\Pagemaker\Pegasus Whirlpool baths\instrucons 2014\pegasus-pneumac-user-instrucons-18-03-2014.indd
Commissioning Checklist &
Fault Finding:
1 - Fill the bath with water to a level of 2’’
above the level of the jets check the system
for leaks, please pay parcular aenon to
the pump unions.
2 - Demonstrate the operaon of the
whirlpool to the customer.
3 - Show the customer how to carry out the
monthly test of the R.C.D.
4 - If the bathroom is to be led aer
installaon please place protecve
wrapping back over the controls to prevent
contaminaon with grout dust.
5 - Hand these instrucons, the electrical
compleon cercate and the system
guarantee to the customer.
6 - Explain how the whole system can be
isolated by means of the fused spur.
Symptom - Press on/o buon - nothing
happens.
Soluon - Check water is above the water
level sensor and that the light is showing on
the water level sensor. (Check power supply
is geng to control box). Check operaon of
the ELCB (if ed) if the ELCB fails to test then
the problem is at the fuse in the fused spur.
If power supply is geng to Control box then
check connecons to pump and ancillarys
are intact and have not been stressed.
Bath Waste:
Only a Pegasus whirlpool waste can be ed
to this bath. An upgrade bath ll waste can
be purchased at a small extra cost (pictured
above).
Head Oce: 61-62 Lower Dock Street, Newport, South Wales NP20 1EF
Telephone: (01633) 244555
Facsimile: (01633) 244881
Email: sales@pegasuswhirlpoolbaths.co.uk
Internet: hp://www. pegasuswhirlpoolbaths.co.uk
....Connued
Altri manuali Pegasus Accessori per cucina e bagno

Pegasus
Pegasus HD879X-0004 Istruzioni per il montaggio

Pegasus
Pegasus 67557-0001 Manuale utente

Pegasus
Pegasus 235-572 Manuale utente

Pegasus
Pegasus 67112-8004 Manuale utente

Pegasus
Pegasus 3121 Manuale utente

Pegasus
Pegasus 65202W-7004 Istruzioni per il montaggio

Pegasus
Pegasus LUXURY AT HAND 67127-8004 Manuale utente

Pegasus
Pegasus 67113-8024H Manuale utente

Pegasus
Pegasus 67125-8004 Manuale utente
Manuali Accessori per cucina e bagno popolari di altre marche

Alpha Bidet
Alpha Bidet Alpha One Manuale utente

InSinkErator
InSinkErator H/HC3300 Manuale di installazione

Clou
Clou Xo type 1 Manuale utente

Kohler
Kohler Contra 26448T-4 Manuale utente

Grohe
Grohe Bridgeford 20 158 Manuale utente

Hans Grohe
Hans Grohe Croma Select S 180 Showerpipe EcoSmart... Manuale utente











