Pepperl+Fuchs VisuNet IXD RM-IXD2100-19U Manuale utente

VisuNet IXD
RM-IXD2100-19U*
PC-IXD2100-19U*
Manual

With regard to the supply of products, the current issue of the following document is applicable: The
General Terms of Delivery for Products and Services of the Electrical ndustry, published by the Central
Association of the Electrical ndustry (Zentralverband Elektrotechnik und Elektroindustrie (ZVE ) e.V.)
in its most recent version as well as the supplementary clause: "Expanded reservation of proprietor-
ship"
Worldwide
Pepperl+Fuchs Group
Lilienthalstr. 200
68307 Mannheim
Germany
Phone: +49 621 776 - 0
E-mail: inf[email protected]hs.com
North merican Headquarters
Pepperl+Fuchs nc.
1600 Enterprise Parkway
Twinsburg, Ohio 44087
USA
Phone: +1 330 425-3555
E-mail: [email protected]
sia Headquarters
Pepperl+Fuchs Pte. Ltd.
P+F Building
18 Ayer Rajah Crescent
Singapore 139942
Phone: +65 6779-9091
E-mail: [email protected]-fuchs.com
https://www.pepperl-fuchs.com

3
VisuNet XD
Contents
2020-04
1 Introduction................................................................................................................ 4
1.1 Content of this Document............................................................................. 4
1.2 Target Group, Personnel ............................................................................... 4
1.3 Symbols Used ................................................................................................ 4
2 Product Description .................................................................................................. 6
2.1 Overview......................................................................................................... 6
2.2 Technical Specifications ............................................................................... 7
2.3 Dimensions................................................................................................... 10
2.4 Scope of Delivery......................................................................................... 12
2.5 Disposal........................................................................................................ 12
3 Mechanical Installation ........................................................................................... 13
3.1 Conditions of Safe Use................................................................................ 13
3.2 General Installation Information ................................................................ 13
3.3 Installation Environment............................................................................. 14
3.4 Preparing the IXD......................................................................................... 15
3.5 Yoke Mount Installation with Pedestal ....................................................... 15
3.5.1 Preparation for Floor Mounting ........................................................ 15
3.5.2 Preparing the Pedestal..................................................................... 16
3.5.3 Attaching the XD to the Yoke and Pedestal...................................... 17
3.5.4 nstalling the Keyboard Tray Kit ........................................................ 24
3.5.5 nstalling the Sunshield Kit ............................................................... 26
3.6 Panel Mount Installation ............................................................................. 28
3.7 Wall Mount ssembly.................................................................................. 29
3.8 G1 ssembly.............................................................................................. 31
3.8.1 Preparation for Floor Mounting with AG1 Housing ........................... 31
3.8.2 Preparing the StandardLine Pedestal .............................................. 32
3.8.3 Attaching the Pedestal to the Housing ............................................. 36
3.8.4 AG1 Housing Assembly ................................................................... 39
3.8.5 Opening the AG1 Housing ............................................................... 40
3.8.6 Grounding the AG1 Housing to the Pedestal.................................... 41
3.8.7 Mounting the Keyboard.................................................................... 45
4 ppendix .................................................................................................................. 47
4.1 ccessories.................................................................................................. 47

2020-04
4
VisuNet XD
ntroduction
1 Introduction
1.1 Content of this Document
This document contains information that you need in order to use your product throughout the
applicable stages of the product life cycle. These can include the following:
•Product identification
•Delivery, transport, and storage
•Mounting and installation
•Commissioning and operation
•Disposal
The documentation consists of the following parts:
•Present document
•nstruction manual
•Datasheet
Additionally, the following parts may belong to the documentation, if applicable:
•EU-type examination certificate
•EU declaration of conformity
•Attestation of conformity
•Certificates
•Control drawings
•Additional documents
1.2 Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation, maintenance, and dismount-
ing lies with the plant operator.
Only appropriately trained and qualified personnel may carry out mounting, installation, com-
missioning, operation, maintenance, and dismounting of the product. The personnel must have
read and understood the instruction manual and the further documentation.
Prior to using the product make yourself familiar with it. Read the document carefully.
1.3 Symbols Used
This document contains symbols for the identification of warning messages and of informative
messages.
Note
This document does not substitute the instruction manual.
Note
For full information on the product, refer to the instruction manual and further documentation on
the nternet at www.pepperl-fuchs.com.

VisuNet XD
ntroduction
2020-04
5
Warning Messages
You will find warning messages, whenever dangers may arise from your actions. t is mandatory
that you observe these warning messages for your personal safety and in order to avoid prop-
erty damage.
Depending on the risk level, the warning messages are displayed in descending order as fol-
lows:
Informative Symbols
ction
This symbol indicates a paragraph with instructions. You are prompted to perform an action or
a sequence of actions.
Danger!
This symbol indicates an imminent danger.
Non-observance will result in personal injury or death.
Warning!
This symbol indicates a possible fault or danger.
Non-observance may cause personal injury or serious property damage.
Caution!
This symbol indicates a possible fault.
Non-observance could interrupt the device and any connected systems and plants, or result in
their complete failure.
Note
This symbol brings important information to your attention.

2020-04
6
VisuNet XD
Product Description
2 Product Description
2.1 Overview
The VisuNet XD RM- XD2100-19U* and PC- XD-2100- 19U* are ATEX/ ECEx certified
devices intended for use in potentially explosive atmospheres, such as Zones 1/21.
The VisuNet XD serves as a thin client- or PC-based operator workstation that uses standard
Ethernet technology to transmit process information from a process control or manufacturing
execution system into hazardous areas.
The assembly consists of several core devices that can be replaced by customers:
•The display unit DPU2100-* is a display panel with optional 10-finger multi-touch sensors.
The display and touch sensors are optically bonded with the hardened front glass.
•The thin client unit TCU1100-* is a computing unit that runs the latest Pepperl+Fuchs RM
Shell 5x or RM Shell 4x firmware. TCUs allow connectivity to various host systems in the
safe area using standard Ethernet technology. For more information on RM Shell, visit
www.pepperl-fuchs.com/RM-SHELL.
•The computing unit PCU1100-* runs an open Microsoft® Windows® operating system,
allowing installation of any software, such as SCADA packages.
•The power supply unit PSU1100-* provides the above-listed devices with 24 V DC power.
t is available in DC and AC versions.
VisuNet IXD System Components
1 DPU
2 TCU/PCU
3 PSU
4 Optional sunshield

VisuNet XD
Product Description
2020-04
7
Several mounting options are available:
•Aluminum bezel prepared for yoke mount
•Aluminum bezel prepared for wall/VESA mount
•Aluminum bezel prepared for panel mount
•nstalled into EX1 housing AG1 (SS304) front opening, for pedestal/ceiling/wall-arm
The above-listed bezel options require additional mounting kits. These kits must be ordered
separately.
2.2 Technical Specifications
Technical Data RM-IXD*
Technical Data PC-IXD*
Technical Data RM-IXD* and PC-IXD*
Note
For a description of the product model nomenclature, view the VisuNet XD PC or RM product
datasheet on www.pepperl-fuchs.com.
Hardware
Processor ntel® Atom™ Bay Trail E3827 1.75 GHz
RAM 2048 MB DDR3L
Mass storage 32 GB industrial grade MLC SSD
Software
Operating system VisuNet RM Shell 5.x (based on Windows 10
oT LTSB)
Hardware
Processor ntel® Atom™ Bay Trail E3845 1.91 GHz
RAM 4096 MB DDR3L
Mass storage 128 GB SSD
Software
Operating system Windows® 10 oT Enterprise LTSB
Supply
Power consumption AC:
115/230 V AC, 1.5 A max, 50/60 Hz
DC:
18 ... 36 V DC, 5.3 A max

2020-04
8
VisuNet XD
Product Description
Interface
nterface type Pepperl+Fuchs interface v1.0 for display units
1 x Ethernet 100/1000BASE-TX (Ex e) or
1 x fiber optic 1000BASE-SX (Multimode) or
1 x fiber optic 1000BASE-LX (Singlemode)
1 x USB 2.0 (Ex e)
2 x USB 1.1 (Ex i; intended for Pepperl+Fuchs keyboard and
mouse)
1 x DC or AC power in (via power supply unit)
Optional:
1 x barcode reader interface Pepperl+Fuchs Pscan-D/B (Ex i)
"interface 3": 1 x barcode reader interface for wired 1-D scanners
DM-160-D*, DM-Z1-160-D-* and base station DMx61-B-* and
DM-Z1-x61-B-* (Ex i)
"interface 4": 1 x barcode reader interface for wired 2-D Scanner
DM-Z1-260-D-* (Ex i)
"interface 5": 1 x RS-232 interface with Power Supply for miscel-
laneous devices and peripherals (Ex i)
1 x RS-232 (Ex e)
1 x RS-485 (Ex e)
1 x Ethernet 100/1000Base-TX (Ex e)
Electromagnetic compatibility
Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
EN 61000-6-4:2007+A1:2011
RoHS
Directive 2011/65/EU (RoHS) EN 50581:2012-09
mbient conditions
Operating temperature -20 ... 60 °C (-4 ... 140 °F)
nstalled in AG1 housing: -20 ... 50 °C (-4 ...
122 °F)
Storage temperature -20 ... 60 °C (-4 ... 140 °F)
nstalled in AG1 housing: -20 ... 50 °C (-4 ...
122 °F)
Relative humidity 93% at 40°C, non-condensating, according to
EN60068-2-78
Altitude Operating altitude max. 2000 m
Shock resistance 3 shocks 20 g , 11 ms all axis, EC 60068-2-27
Vibration resistance 5 ... 500 Hz, +/- 0.075 mm , 1.5 g, 10 cycles
per axis according to EN60068-2-6
Mechanical specifications
Degree of protection P66 (individual components and entire sys-
tem with housing)
Material Panel: anodized aluminum (TCU, PSU), pow-
der coated aluminum (DPU)
Bezel: powder coated aluminum

VisuNet XD
Product Description
2020-04
9
Marking
Mass panel with DC: 22 kg , panel with AC: 23 kg ,
system housing AG1: 19 kg
Dimensions panel with DC: 542 mm x 460 x 132 mm
panel with AC: 542 mm x 460 mm x 149 mm
panel with housing: 582 mm x 490 mm x 224
mm
Mechanical specifications
Note
For more technical information such as electrical data and connection details, refer to the
manuals and instruction manuals of the individual components:
•Display Unit DPU2100-J1*
•AC Power Supply Unit PSU1100-J1-AC-N0
•DC Power Supply Unit PSU1100-J1-DC-N0
•Thin Client Units TCU1100-J1-*
•Computing Units PCU1100-J1-*
TEX
RM- XD2100-J1-* / PC- XD2100-J1-* 2G Ex eb q ib [ib] C T4 Gb
2D Ex tb [ib] C T85°C Db
IECEx
RM- XD2100-J1-* / PC- XD2100-J1-* Ex eb q ib [ib] C T4 Gb
Ex tb [ib] C T85°C Db
DC Version Label
C Version Label

2020-04
10
VisuNet XD
Product Description
2.3 Dimensions
Panel Dimensions with Bezel
Figure 2.1 Panel cut-out dimensinons with bezel
Label for DC Version in G1 Housing
Label for C Version in G1 Housing
542
149.2
460
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Pepperl+Fuchs Scrivania