PERCEPT Milestone XProtect Guida rapida alla configurazione

Milestone XProtect® VMS /
IONODES PERCEPT Body Camera
Integration Guide
Document Date: March 3rd, 2022

2
CONTENTS
1 Introduction ....................................................................................................................................... 3
2 High Level Diagram ........................................................................................................................... 3
3 Configuring the body camera before integration .......................................................................... 4
3.1 Create a new dedicated ONVIF user (recommended)................................................................ 4
3.2 Configure video profiles ................................................................................................................ 5
3.3 Setup local recording on the body camera.................................................................................. 6
3.4 Setup time synchronization on the body camera....................................................................... 7
3.5 Enable data transfer mode on Docking Station .......................................................................... 8
4 Configuring the VMS before integration ......................................................................................... 9
4.1 Configure the time synchronization on the VMS ........................................................................ 9
5 Adding the PERCEPT Body Camera to Milestone XProtect VMS ................................................. 10
6 Configuring the PERCEPT Body Camera inside Milestone VMS.................................................. 15
4.1 Change the configuration of the profiles on the body camera ...............................................15
4.2 Assign different profiles for different tasks...............................................................................16
4.3 Enable the recording to the VMS + edge storage retrieval ......................................................17
4.4 Configure the recording rules.....................................................................................................19
4.5 Configure the motion detection .................................................................................................20
4.6 Configure the dewarping for the body camera’s Panomorph lens.........................................21
4.7 Configure the sub-components for Milestone Smart Client usage.........................................22
7 Viewing live and recorded video from the PERCEPT Body Camera inside the VMS ................. 23
8 Using two-way audio functionality inside the VMS ...................................................................... 25

3
1Introduction
One of the key advantages of the IONODES PERCEPT Body Camera compared to other body worn
video surveillance solutions is its versatile integration with Milestone XProtect VMS. It uses
extensive features from ONVIF profiles G, S and T, along with flexible network configurations (LAN
via docking station, Wi-Fi) for live video and edge recording retrieval.
This integration is supported as of IONODES PERCEPT firmware 10.3.0.12 and has been validated
with Milestone XProtect 2021 R2 and higher. This document shows steps required for a simple
integration scenario. Integrators shall adjust to their specific system.
2Typical Deployment
A typical deployment scenario includes the PERCEPT Body Camera, a Docking Station , a Wi-Fi
access point, the LAN infrastructure and the local VMS (Milestone XProtect in this case). The
PERCEPT Body Camera can record data either directly to the local VMS through Wi-Fi or to its
internal memory and then use the wired Ethernet via the Docking Station to offload the contents
to the local VMS.

4
3Configuring the body camera before integration
Note: As a best practice before proceeding, please consider performing a reset to default factory
settings and reinitialization of the PERCEPT Body Camera. This will remove any unwanted
configuration left over from past usage of the device. Make sure to set it up on the same subnet
as the Milestone server. For more details, please consult the PERCEPT User Manual and/or
PERCEPT Quick Start Guide.
3.1 Create a new dedicated ONVIF user (recommended)
1. Once logged into the PERCEPT’s Web GUI, go to the Security page
2. Click on the Create User button
3. In the New User pop-up window, enter Username
4. Enter Password and repeat it to confirm
5. Select Super user role
6. Click on Create User

5
Note: The default administrator account could also be used for integrating the body camera to the
VMS. However, it is considered good practice from a security perspective to create a dedicated
ONVIF user account, specifically for this purpose. The role “Superuser” gives the account
permissions for almost everything (the only exception is managing other users on the device).
This role is required to perform firmware upgrades from the VMS.
3.2 Configure video profiles
The PERCEPT Body Camera supports two (2) H.264/265 video encoder profiles and one (1) MJPEG
profile. Each profile enabled in the PERCEPT web GUI will be accessible by Milestone for
configurable usage.
1. From the Configuration page
2. Select the Video tab
3. Enable and configure each video Profile as required

6
Note: The Encoder Type (codec) and enabled profiles are detected by the VMS when adding the device.
These settings must therefore be configured in the PERCEPT Body Camera before adding the
device to the VMS. Changing Encoder Type will reboot the device.
Note: Once added, modifications should only be done from within the VMS and not from the device’s
web interface.
3.3 Setup local recording on the body camera
1. From the Configuration page
2. Select the Recorder tab
3. Select the Media Recording subtab
4. Select the Video Profile for edge/onboard storage recording.

7
Note: Profile #3 (MJPEG) is not supported for edge/onboard storage recording. To use local recording
on the PERCEPT, Profile #1 or Profile #2 must be enabled.
Note: The profile configured for local recording on the PERCEPT is not required to be the same as the
stream profile used for recording within Milestone VMS.
Note: Advanced recording configurations, such as grooming, pre-recording and post-recording, are
outside the scope of this integration guide. Refer to the PERCEPT User Manual for advanced
configuration.
3.4 Setup time synchronization on the body camera
1. From the Configuration page
2. Select the System tab
3. In the NTP Configuration section, enter the IP address of the same network time server
used by Milestone VMS to synchronize time
Note: It is possible to use an Internet-based NTP server if the body camera is connected to a network
that has Internet access.

8
3.5 Enable data transfer mode on Docking Station
When using a PERCEPT-DCK docking station for offloading data to the VMS, the user will need to
ensure that Online Mode (data transfer via Ethernet) is enabled for the docking station.
1. From the Configuration page
2. Select the System tab
3. Select the Docking Station subtab and make sure that “Enable Online Mode” is checked
Note: If the edge retrieval is enabled, it can create a bandwidth surge of more than 200Mbps when
the body camera starts offloading data to the VMS. Please ensure that the network can handle
the increased traffic.
For configuring advanced settings related to the behavior of the Docking Station please refer to
the PERCEPT Docking Station User Manual.

9
4Configuring the VMS before integration
4.1 Configure the time synchronization on the VMS
The Milestone Recording Server uses by default the time that is set on the workstation PC
used to host it.
To change the time settings on the host PC of the Milestone Recording Server:
1. From the Control Panel > Clock and Region
2. Select the Set the time and date tab
3. Select the Internet Time and then go to Change settings…
4. Select the Synchronize with an Internet time server and make sure to use a valid online
time server

10
5Adding the PERCEPT Body Camera to Milestone XProtect VMS
Now that the basics are covered on the PERCEPT Body Camera, it’s time to add it to the Milestone
XProtect VMS.
1. In the Milestone XProtect Management Client, click on Recording Servers
2. Right-click on the recording server where you want to add the PERCEPT Body Camera
3. Choose Add Hardware from the pop-up menu
Altri manuali per Milestone XProtect
1
Indice
Altri manuali PERCEPT Macchina fotografica digitale