PERCo IR-10 Manuale utente

Proximity Card Reader
IR-10
CERTIFICATE AND OPERATION MANUAL

PERCo-Web system
Proximity Card Reader
IR-10
Certificate and Operation Manual
TC RU C-RU.МЛ02.В.00273
ТУ 4372-040-88226999-2014

CONTENTS
1GENERAL INFORMATION .........................................................................................3
2TECHNICAL SPECIFICATIONS .................................................................................4
3DELIVERY SET...........................................................................................................4
4PRODUCT DESCRIPTION .........................................................................................5
4.1 Design ...................................................................................................................5
4.2 Operating principle ................................................................................................5
4.3 Data transmitting via Wiegand interface ................................................................6
5CONFIGURATION ......................................................................................................8
5.1 Selection of reader number in RS-485 interface....................................................8
5.2 Operation in Wiegand mode..................................................................................8
5.2.1 Indication setting ............................................................................................8
5.2.2 Changing the format of output data ................................................................9
6INSTALLATION.........................................................................................................10
6.1 Safety requirements ............................................................................................10
6.2 Installation features .............................................................................................10
6.3 Tools and equipment required for installation......................................................10
6.4 Required cables...................................................................................................11
6.5 Installation sequence...........................................................................................11
7TROUBLESHOOTING ..............................................................................................14
8PERCO WARRANTY ................................................................................................15

IR-10 Proximity Card Reader
1 GENERAL INFORMATION
IR-10 long range proximity card reader (hereinafter– the reader) is designed for reading
and interpretation of proximity card identifier and for transferring of identifier to ACS
controller. The reader is designed for the use at automotive check-point. Up to four
readers can be installed for each passage direction.
Attention!
The reader is designed for outdoor use only.
People who have implanted pacemakers shall avoid continuous influence of
electromagnetic radiation produced by the reader.
The reader with regard to resistance to environmental exposure complies with
GOST15150, category N1 (for an outdoor application).
Operation of the turnstile housing is allowed at ambient air temperature from -40°Сto
+40°Сand at relative air humidity of up to 100% at +25°С.
Storage of the reader is allowed in indoor facilities at the ambient air temperature from
-40°Сto +40°Сand relative air humidity of up to 98% at +25°С.
The reader has the marking on the inner side of the housing. The marking contains the
product name, the model abbreviation, the date of manufacture, the serial number; allowed
power voltage, consumption current.
The reader in the original package should be transported in closed freight containers or
other closed type cargo transport units.
The reader is packed in a cardboard box that protects it from being damaged during
transportation and storage.
Overall dimensions of the box (L × W × H). ..............................................425×311×174 mm
Weight of the box................................................................................................ max. 3.5 kg
After transportation or storage at temperatures below zero or at high air humidity, prior to
installation the reader must be kept in the original package for no less than 24 hours
indoors under normal climate conditions prior to installation.
Due to continuous improvement of products the Manufacturer reserves the right to modify,
without notice, the product design not aggravating its technical specifications.
3

Certificate & Operation Manual
2 TECHNICAL SPECIFICATIONS
Rated operating voltage1........................................................................................ 12 VDC
Operating voltage limits1 ................................................................................ 10.8–14 VDC
Consumption current .................................................................................................. 1.1 A
Power consumption ............................................................................................ max. 14 W
Controller connection interface .............................................................. RS-485, Wiegand2
Card reading distance at the rated operating voltage for different card types:
HID ProxCard II cards ............................................................................ max. 60 cm
EM-Marin IL-05ELR cards .................................................................... max. 100 cm
EM-Marin EM4100 cards ........................................................................ max. 70 cm
Length of cables (power and control) ............................................................................. 3 m
Mean lifetime ........................................................................................................... 8 years
Electric shock protection class ...................................................................... III (IEC 61140)
Ingress protection rating ........................................................................... IP54 (EN 60529)
Overall dimensions of reader (with a mounting arm) .............................. 408300×266 mm
Reader weight (with a mounting arm) ............................................................... max. 2.5 kg
3 DELIVERY SET
Attention!
The completeness of the delivery set shall be checked upon receipt.
Standard delivery set
Reader ............................................................................................................................... 1
Mounting arm ..................................................................................................................... 1
Jumper ............................................................................................................................... 3
Installation kit:
plastic dowel ............................................................................................................ 4
screw ....................................................................................................................... 4
Certificate and operation manual ....................................................................................... 1
Package ............................................................................................................................. 1
Additional equipment
BH-03 post ......................................................................................................................... 1
Power supply unit .............................................................................................................. 1
1 As a power supply it is recommended to use DC source with linear voltage stabilization and
output pulsation amplitude max. 50 mV.
2Wiegand, Wiegand 26, Wiegand 37, Wiegand 42.
4

IR-10 Proximity Card Reader
4 PRODUCT DESCRIPTION
4.1 Design
The reader consists of the unit in plastic housing, on the front side of which there are three
indicators: green (top), yellow (central), red (down). The mounting arm included in the
delivery set can be used for installation. Electronic components are protected from
negative environmental effects by means of plastic plate with sealing gasket. Cables are
connected at the back side of the reader.
The reader is equipped with integrated sound indicator. Code reading is confirmed by a
short sound signal and short status change of the yellow (central) indicator (it turns on, if it
was off, or it turns off, if it was on).
Reader board (see Fig. 1) contains three configurative jumpers (ХP1, ХP2 and ХP3) and
one wire jumper ХP5 – «disconnection of EOL resistor» (the jumper is present – the EOL
resistor is present, if the jumper is removed (cut) – the EOL resistor is disconnected).
Figure 1. The board of the reader
4.2 Operating principle
Readers provide code reading from Proximity identifiers with operation frequency 125 kHz
(hereinafter – the identifier) produced by HID Corporation, type: ProxCard II, ISOProx II
(standard formats HID: 26 bit (H10301), 37 bit (H10302, H10304)), and also IL-05ELR
and EM4100/4102 identifiers produced by EM-Microelectronic-Marin SA.
Code reading is performed when the identifier is presented to the reader. Maximum
operating distance between the identifier and the reader depends on the type of the
identifier, it is in the range from 50 to 100 cm. The identifier can be placed inside pocket,
wallet or any other radio transparent container (cover).
5

Certificate & Operation Manual
Figure 2. Reader operation
When the reader is switched on it radiates low frequency (125 kHz) electromagnetic field.
Caught in this field the identifier is activated and starts transmitting individual encoded
signal that is received by the reader.
Reader transforms the received signal in accordance with an external device interface and
sends it to controller of external device via RS-485 or Wiegand interfaces.
Data is transmitted to the external controller at one time at the moment of first positive
signal receipt from identifier. Repeated data transfer is possible not earlier than 500 ms
after identifier leaves stable reception zone.
4.3 Data transmitting via Wiegand interface
Two wires are used for transmission: «data 0» and «data 1». When logic level «0» occurs
on one of the wires it signals the presence of bit with appropriate value in coded mark.
Time response characteristics of output data format:
Duration of data pulse ................................................................................... 100 mcs
Pulse-time ........................................................................................................... 1 ms
Figure 3. Formation of output reader signals and their diagrams
6

IR-10 Proximity Card Reader
All bytes are transmitted with high-order bits forward.
The length of the coded mark depends on the output data format set at assembly and can
be either fixed or specified by data dimension received from identifier.
Following rules are applied when there is difference between coded mark received from
identifier and the output coded mark:
- If the input coded mark from identifier is longer than output mark the excessive high-
order bits are truncated.
- If the input coded mark from identifier is shorter than output mark the missing high-
order bits are padded with zeros.
The structure of coded mark and order of parities in it for fixed length formats are
presented in the following Figures:
- The identifier encoded signal includes the even number of bits (N/2 – integer):
- The identifier encoded signal includes the uneven number of bits (N/2 – non
integer):
The structure of output coded mark in Wiegand 26 (H10301) format is presented in Figure:
1 – Control bit (corresponds with the even parity for the next 12 bit data)
2 – Byte code
3 – High-order byte of card number
4 – Low-order byte of card number
5 – Control bit (corresponds with the odd parity for the previous 12 bit data).
7

Certificate & Operation Manual
5 CONFIGURATION
5.1 Selection of reader number in RS-485 interface
When connected via RS-485 interface the reader starts operating according to reader
connection protocol in PERCo Web system, it can be used as an external reader for
controllers of the system.
Operation of reader in PERCo Web is similar to operation of IR-xx series readers. The
difference is that in this case up to eight readers can be connected to one controller. All
odd-numbered readers are considered by the controller to be “reader No. 1”, and all even-
numbered readers are considered to be “reader No. 2”. Number of reader is bound to
passage direction. Binding is made by computer software.
Number of reader from 1 to 8 is set with the use of XP1, XP2, XP3 configurative jumpers
(see Fig. 1). Numbers of readers corresponding to position of jumpers are given in
Table 1.
Table 1. Number of reader
Jumper is installed
No. ХP1 ХP2 ХP3
1 No No No
2 No No Yes
3 No Yes No
4 No Yes Yes
5 Yes No No
6 Yes No Yes
7 Yes Yes No
8 Yes Yes Yes
5.2 Operation in Wiegand mode
In case there is no connection via RS-485 interface, the reader starts operating via
Wiegand interface and can be used as an external reader for ACS controllers.
5.2.1 Indication setting
Indication mode controlled by ACS controller when connected via Wiegand interface
depends on XP1 jumper on the board of the controller (see Fig. 1). If the jumper is
installed, “single line” control variant is set; if the jumper is removed, “double line” control
variant is set. (ХP2 and ХP3 jumpers are not used in this case).
Control signals are transmitted via blue and yellow wires of the reader connection cable
from the controller. Reader indication for both variants depending on received control
signals is given in Table 2.
8

IR-10 Proximity Card Reader
Table 2. Reader indication
Control signals Indication
Blue wire Yellow wire «single line» «double line»
0 0 Green Red and Green
0 HZ Green Red
HZ 0 Red Green
HZ HZ Red Yellow
Key to Table 2:
0 – control line is connected to negative terminal of power supply;
HZ – high resistance on control line (control line is not connected to negative
terminal of power supply)
In order to control sound indicator externally brown wire shall be connected to negative
terminal of power supply.
5.2.2 Changing the format of output data
Attention!
Switching over the reader into Wiegand formats does not prevent it from reading
cards of other formats and delivering read code to an output of a reader in the set
format.
Changing of format of Wiegand interface output data is defined by connection point of
orange wire (WF – Wiegand-Format on Fig. 6) at the output of standard connection cable
of the reader. Connection point is selected according to Table 3.
Table 3. Setting of output data format
Connection point of WF orange wire Output data format
(not connected) Wiegand 26
D0 (green) Wiegand 37
+12В(red) Wiegand 42
«ground» (black + shield) Wiegand
9
Indice
Altri manuali PERCo Lettore di schede

PERCo
PERCo IR-04.1 Istruzioni per l'installazione e il funzionamento

PERCo
PERCo IRP-01 Manuale di installazione

PERCo
PERCo IC-05 Istruzioni per l'installazione e il funzionamento

PERCo
PERCo IC-03.1 Istruzioni per l'installazione e il funzionamento

PERCo
PERCo IR-03.1 Istruzioni per l'installazione e il funzionamento

PERCo
PERCo RP-15.2 Manuale utente

PERCo
PERCo IC02.1 Istruzioni per l'installazione e il funzionamento