PERCo RTC-15.3 Istruzioni per l'installazione e il funzionamento

ASSEMBLY AND OPERATION MANUAL
WARRANTY CARD
RTC-15.3
Protective Capony

Protective Canopy
RTC-15.3
Assembly and Operation Manual
Warranty Card

CONTENT:
1APPLICATION......................................................................................................................... 3
2OPERATION CONDITIONS.................................................................................................... 3
3TECHNICAL SPECIFICATIONS ............................................................................................. 3
4DELIVERY SET....................................................................................................................... 4
4.1Standard delivery set......................................................................................................... 4
4.2Optional equipment supplied on request........................................................................... 4
5DESIGN................................................................................................................................... 4
5.1Main features..................................................................................................................... 4
5.2The canopy design............................................................................................................ 4
6SAFETY REQUIREMENTS..................................................................................................... 6
6.1Installation safety requirements......................................................................................... 6
6.2Operational safety requirements....................................................................................... 6
7INSTALLATION WORK........................................................................................................... 7
7.1General recommendations................................................................................................ 7
7.2Installation tools................................................................................................................. 7
7.3Canopy installation............................................................................................................ 7
8TRANSPORTATION AND STORAGE .................................................................................. 10
9WARRANTY PERCo............................................................................................................. 11

RTC-15.3 Protective Canopy
Dear customers!
We thank You for choosing the turnstile manufactured by PERCo.
You have purchased a high quality product, which will be long lasting
in operation provided that installation and operation rules are observed.
The Operation Manual (the Manual) of the RTC-15.3 Protective canopy for the RTD-15 Full
height rotor turnstile contains data on transportation, storage, installation, operation,
maintenance and warranty of the product. The installation should be undertaken in strict
accordance with this Manual.
1 APPLICATION
The RTC-15.3 Protective canopy (the canopy) is designed for use together with the
RTD-15 Full height rotor turnstile (the turnstile) as protection of the turnstile against direct exposure
to the elements.
Warning!
The RTC-15.3 canopy is compatible only with the RTD-15 turnstiles with serial numbers
67хххххх and is not compatible with the RTD-15 turnstiles with serial numbers 46хххххх!
2 OPERATION CONDITIONS
The canopy, in accordance with the resistance to environmental exposure, complies with
GOST 15150-69, Category N1 (outdoor operation).
Operation of the canopy is allowed at ambient temperature from -40°C to +40°C and relative air
humidity of up to 98% at +25°C.
3 TECHNICAL SPECIFICATIONS
Overall dimensions (H × W × D) .................................................................... 2379×1807×2594 mm
Weight (net) ...................................................................................................................... max 70 kg
Mean lifetime ............................................................................................................................. min 8
Figure 1. Overall canopy dimensions (frontal view)
3

Assembly and Operation Manual
4 DELIVERY SET
4.1 Standard delivery set
Primary parts:
Canopy’s half-frame #1............................................................................................................ 1
Canopy’s half-frame #2............................................................................................................ 1
Post ......................................................................................................................................... 4
Jointing plate ........................................................................................................................... 1
Fasteners:
Hex socket screw M6×20 ......................................................................................................21
Hex socket screw M8×30 ....................................................................................................... 8
Washer 6 ...............................................................................................................................16
Washer 8 ................................................................................................................................ 8
Spring washer 6 .................................................................................................................... 21
Spring washer 8 ...................................................................................................................... 8
Self-tapping screw 4.2×16 .......................................................................................................4
Plug Ø16 ................................................................................................................................. 5
In-line documentation:
Assembly & operation manual with warranty card .................................................................. 1
Package:
Package box ........................................................................................................................... 3
4.2 Optional equipment supplied on request
Metal anchor with bolt M10×60 PFG IR 10-15 («SORMAT», Finland) ..................................16
5 DESIGN
5.1 Main features
High corrosion resistance of the aluminium frame ensures long period of service even in
unfavourable environments/
Low weight makes the installation easier/
High durability polymeric powder keeps the outward appearance essentially unchanged for
many years of service.
5.2 The canopy design
The design is shown in Fig. 2. Numbers of the position correspond to Fig.2.
The canopy consists:
two half-frame (1) and (2) with transparent infill and the sloping drain;
four posts (3);
jointing plate (6).
The half-frames (1) and (2), and the posts (3) with bottom flanges (4) for fixing the posts to the
mounting surface and top flanges (5) for fixing the posts to the half-frames assembly, are made of
high durability aluminum profile.
The canopy posts are to be fixed to the foundation surface with anchor bolts M10 through
mounting holes in supporting flanges.
Each canopy’s half-frame shall be fixed: to two posts with screws M6×20 and to the side part of the
turnstile top channel with screws M8×30 (see Figure 2).
The canopy’s half-frame shall be connected in their upper part with screws M6×20 (see Figure 3).
The joint line between the half-frames is covered by a jointing plate (6) and fix by four self-tapping
screws 4.2×16.
Each half-frame has a sloping drain (7) for drainage.
4

RTC-15.3 Protective Canopy
Figure 2. The canopy design:
1 and 2– half-frames; 3 – post; 4 – bottom flange; 5 – top flange;
6 – jointing plate; 7 – drain
5

Assembly and Operation Manual
Figure 3. Mounting half-frames among themselves
6 SAFETY REQUIREMENTS
6.1 Installation safety requirements
Installation of the canopy should be carried out by qualified personnel only, in strict accordance
with this Manual and general requirements for installation work.
Warning! While doing the installation work:
use only serviceable tools;
be particularly careful when installing parts of the canopy before they are secured in
place, prevent the parts from fall.
6.2 Operational safety requirements
Do not:
use the canopy if it is not fixed to the turnstile.
make mechanical shock and jerking of the canopy.
use substances and tools that may cause damage to the surface of the canopy.
Make sure that snow that may cover the canopy in winters is not higher than 200 mm.
6

RTC-15.3 Protective Canopy
7 INSTALLATION WORK
7.1 General recommendations
Warning!
The manufacturer will not accept liability for any damage to the canopy
or other equipment, or otherwise loss caused as a result of improper installation, and will
dismiss any claims by the customer should the installation work be carried out not in
accordance with this Manual.
Installation is an operation substantially responsible for durability and serviceable life of the
canopy. Study this section carefully before commencing the installation work, and strictly follow the
instructions.
We advise:
installation to be carried by at least two persons in assembly and installation work;
mounting the canopy on flat, solid concrete floors (grade 400 or higher), stone or similar
foundations at least 150 mm thick;
using reinforcing elements 500×500×500 mm for weaker foundations;
using mounting hardware as recommended in sect. 4.2.
7.2 Installation tools
Use the following tools for the installation work:
1.21.5 kW electric perforator;
0.6 kW electric drill;
Ø16 mm carbide drill bits;
Ø3.5 drill bits;
SW5; SW6 hex-nut wrenches;
PH2 cross-tip screwdriver, 150 mm;
pair of trammels;
3 m tape-measure;
level gauge;
two stepladders (four steps or more).
Note:
Use of other similar tools is allowed as long as it does not reduce quality of the installation
work.
7.3 Canopy installation
Recommendations how to prepare mounting holes in the foundation (the mounting surface) are
given with regard to anchor bolts for solid concrete floors or similar foundations (see sect. 7.1). Use
relevant mounting hardware for installation on different foundations.
1. Unpack the canopy, check completeness of the delivery set according to sect. 4.1.
2. Mark out the mounting holes for installation of the posts (3) according to Fig. 4. Carry out the
marking together with that for turnstile mounting holes given
in the Operational Manual to the RTD-15 Full Height Rotor Turnstile. Symmetry axis of
turnstile and canopy mounting holes geometrically coincide (Figure 4).
3. Prepare holes for the anchor bolts.
7

Assembly and Operation Manual
Figure 4. Hole pattern for mounting of the canopy posts (3) relative to the turnstile mounting
holes:
A – mounting point of the turnstile barrier section.
L – mounting point of the turnstile left guide barrier section.
R – mounting point of the turnstile right guide barrier section.
Figure 4 shows a sketch layout of the turnstile mounting holes. Exact coordinates of the holes in A,
Land Rmounting points are given in the Operational Manual to the RTD-15 Full Height Rotor
Turnstile.
8

RTC-15.3 Protective Canopy
4. Set the anchors all the way down the prepared holes.
Warning!
Further work should be carried out after installation of the RTD-15 turnstile.
Be particularly careful when installing parts of the canopy before they are secured in
place, prevent the parts from fall.
5. Erect and fix the posts with anchor bolts observing their verticality by means of a level gauge,
use insertions when necessary.
6. Remove the plugs from the side surfaces of the turnstile top channel (4 plugs on each side of
the channel).
7. Install the first canopy half-frame on the upper flanges of the posts from one side of RTD-15
turnstile, matching fixation holes with the holes in the posts. Fix the canopy half-frame with
screws M6×20 with washers to each stand, wrench SW5 (see Figure 5).
Figure 5. Juncture of the canopy to the turnstile top channel
8. Fix canopy half-frame with four bolts M8×30 to the turnstile top channel, wrench SW6 (see
Figure 5). Tightening of bolts is preliminary. It is recommended to seal the joint of flange and
top channel with atmospheric silicon sealer before fixing of the bolts.
9. Similarly, carry out the installation of the second half-frame of the canopy on the other side of
the turnstile. Tightening of bolts is preliminary.
9