Pioneer DR024GHFD18HT2 Manuale utente

Installation Manual
CENTRAL SPLIT AIR CONDITIONER
IMPORTANT NOTICE: Thank you very much for purchasing this Air Conditioner. Please read this manual carefully before
installing or operating your new air conditioning system. Be sure to save this manual for future reference.
HIGH EFFICENCY
AIR HANDLER
Models:
•DR024GHFD18HT2
•DR036GHFD18HT2
•DR048GHFD18HT2
•DR060GHFD18HT2
- R-410A REFRIGERANT
- 208/230V, 1 Phase, 60Hz
- 18 SEER

This page intentionally left blank.

Contents
Safety Precautions..........................................................................................................................................1
Components of the Air Conditioner..............................................................................................................3
Troubleshooting .............................................................................................................................................4
Installation and Maintenance...................................................................................................5
1. Safety Notice ................................................................................................................................................5
2. Installation of the Indoor Unit .......................................................................................................................5
2.1. Initial Check ..........................................................................................................................................5
2.2. Installation Location..............................................................................................................................6
2.3. Installation ............................................................................................................................................6
2.4. Air Duct .................................................................................................................................................6
4.
Refrigerant Pipe ............................................................................................................................................8
4.1. Pipe Material.........................................................................................................................................8
4.2. Piping Connection.................................................................................................................................8
5.
Drain Piping...................................................................................................................................................8
6.
Electrical Wiring ............................................................................................................................................9
6.1. Electrical Installation.............................................................................................................................9
6.2. Change of Static Pressure....................................................................................................................10
7.
Test Run ........................................................................................................................................................10
8.
TXV Replacement Information ......................................................................................................................11
9.
Electric Heat Kit Selection Table....................................................................................................................11
Filter Cleaning ................................................................................................................................................4
3.Special Instructions for Down-flow Conversion ............................................................................................7

1
Safety Precautions
DANGER
WARNING
CAUTION
NOTE
Alert Symbols:
DANGER
WARNING
Installation, maintenance, and repair of this unit must be performed by qualified, licensed service personnel.
Read these instructions thoroughly before installation or operation. Failure to follow these instructions may
result in improper installation, service or maintenance, possibly resulting in fire, electrical shock, property
damage, personal injury or death.
Before installation, check if the voltage of the power supply at installation site is the same as the voltage
shown on the nameplate.
Do not perform any alterations to this product, otherwise, it can cause water leakage,
breakdown, short circuit, electric shock, fire, etc.
Piping, welding, and other such work should be carried out far away from the
flammable and explosive materials, including air conditioner refrigerant, to guarantee
the security and safety of the site.
To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit in
a place in which sea water can splash directly onto it, or in sulfurous air, such as
near a spa. Do not install the air conditioner where excessively high heat-generating
objects are located.
If the supply cord is damaged, it must be replaced by the factory or its service
department in order to avoid danger.
The place where this product is installed must have reliable electrical grounding
facilities and protections. Please do not connect the grounding of this product to any
various sorts of air feeding ducts, drain pipes, lightning protection facilities, as well as
other piping lines, to avoid electric shock and damage caused by external factors.
All wiring must be done by a qualified electrician. All wiring operations must be
conducted according to the local electrical codes.
It is strongly advised to consider the capacity of the electric current of the available
electrical meter and socket before installation.
The power source of where this product is installed should have an independent
leakage protection device. An electric current over-load protection device should also
be provided for this product.
Never use gasoline or other inflammable gas near the air conditioner to avoid
danger. When any abnormality, like burnt smells, deformation, fire, smoke, etc. is
discovered, immediately cut off the main power supply to the air conditioner and
contact the dealer.
The first 6 inches of supply air plenum and duct work must be constructed of sheet
metal, as required by NFPA 90B.
The supply air plenum or duct must have a solid sheet metal bottom piece directly
after the air handler unit, with no opening, registers or flexible air ducts located in it.
If flexible supply air ducts are used, they may be located only in the side walls of the
rectangular plenum, a minimum of 6 inches from the solid bottom.
Read this manual carefully before using this air conditioner. If you still have any
difficulties or problems, consult your dealer for further assistance.
The air conditioner is designed to provide you with comfortable room conditions.
Use this unit only for its intended purpose, as described in this instruction manual.
: This symbol refers to a hazard which can result in severe personal injury or death.
: This symbol refers to a hazard or an unsafe practice which may result in severe personal injury
or death.
: This symbol refers to a hazard or an unsafe practice which may result in minor personal injury,
product, or property damage.
: This mark refers to the remarks and instruction to the operation, maintenance and service.

Safety Precautions
WARNING
PROPOSITION 65:
This appliance contains fiberglass insulation. Respirable particles of fiberglass are
known in the State of California to cause cancer.
All manufacturer products meet current federal OSHA Guidelines for safety. California
Proposition 65 warnings are required for certain products, which are not covered by
the OSHA standards.
California's Proposition 65 requires warnings for products sold in California that
contain or produce any of over 600 listed chemicals known to the State of California to
cause cancer or birth defects, such as fiberglass insulation, lead in brass, and
combustion products from natural gas.
All "new equipment" shipped for sale in California will have labels stating that the
product contains and/or produces Proposition 65 chemicals. Although we have not
changed our processes, having the same label on all our products facilitates
manufacturing and shipping. We cannot always know "when, or if" products will be
sold in the California market.
You may receive inquiries from customers about chemicals found in, or produced by,
some of our heating and air conditioning equipment, or found in natural gas used with
some of our products. Listed below are those chemicals and substances commonly
associated with similar equipment in our industry and other manufacturers:
-Glass Wool (Fiberglass) Insulation
-Carbon Monoxide(CO)
-Formaldehyde
-Benzene
More details are available at the websites for OSHA (Occupational Safety and Health
Administration), at www.osha.gov and the State of California's OEHHA (Office of
Environmental Health Hazard Assessment), at www.oehha.org. Consumer education
is important since the chemicals and substances on the list are found in our daily lives.
Most consumers are aware that products present safety and health risks, when
improperly used, handled and maintained.
CAUTION
Do not turn the air conditioner on and off from the main power switch. Use the
ON/OFF operation button unless not possible.
Do not stick anything into the air inlet and air outlet of both the indoor and outdoor
units. This is dangerous as the fan could be rotating at a high speed.
Do not cool or heat the room to extreme temperatures if babies or invalids are present.
Type and rating of circuit breakers / ELB are detailed below.
Themethodofconnectionoftheappliancetotheelectricalsupplyandinterconnection
of separate components are detailed below.
The information of dimensions of the space necessary for correct installation of the
appliance, including the minimum permissible distances to adjacent structures, is
detailed below.
The range of external static pressures for ducted appliances is detailed below.
Ensure that the blower motor support is tight (3-motor mounting bolts). Next, check
to see if the wheel is tightly secured to the motor shaft before operation of the unit.
NOTE:
Storage Conditions: Temperature -13~140℉ (-25~60℃)
Humidity 30% ~ 80%
2

3
Components of the Air Conditioner
Indoor Unit
NOTE: These figures are based on external views of the standard model.
Consequently, the shape may differ for the air conditioner model you have selected.
1. Air Outlet Flange
2. Low Voltage Connection (for 24V)
3. CircuitBreakerSwitch (Optional)
4. Refrigerant Pipe (Gas)
5. Refrigerant Pipe (Liquid)
6. Air Inlet
7. AuxiliaryDrainageHole
8. DrainageHole
9. AuxiliaryDrainage Hole
10. High Voltage Connection
11. High Voltage Connection
12. Air Outlet
13. Auxiliary Heater (Optional)
14. Electronic Control Box
15. Fan Volute
16. Evaporator
17. Drainage Pan
18. Filter Cover
13
14
15
16
17
18
1
2
3
4
5
6
7
8
9
10
11
12

Troubleshooting
Troubleshooting
CAUTION
If drainage water overflows from the indoor unit, cease all operation and contact your dealer.
If you smell or see white smoke coming out of the unit, turn OFF the main power supply and
contact your dealer.
1. If Issues Persist
If the issues continue even after checking the following, contact your dealer and have the following
information ready:
(1) Unit Model Name
(2) Description of the Issue
2. No Operation
Check whether the SET TEMP is set to the desired temperature.
3. Not Cooling or Heating Properly
●Check for obstruction of air flow at the outdoor or indoor units.
●Check if there are too many heating sources in the room.
●Check if the air filter is clogged with dust or other obstructions.
●Check if doors or windows are open.
●Check if the ambient temperature conditions are within the operation range.
4. The Following Are Not Abnormal:
●Odor from Indoor Unit
Unpleasant odor diffuses from indoor unit after a long period of time. Clean the air filter and panels and
ensure that there is sufficient ventilation.
●Sounds from Moving Parts
When starting or stopping the system, a sound might be made. However, this is likely due to thermal
deformation of plastic parts. If so, it is not abnormal.
●Steam from Outdoor Heat Exchanger
During the defrosting operation, ice on the outdoor heat exchanger melts, resulting in steam.
●Dew on Air Panel
When the cooling operation operates for an extended period of time under high humidity conditions, dew can
form on the air panel.
●Refrigerant Flow Sound
While the system is starting or stopping, the sound of refrigerant flowing may be heard.
Filter Cleaning (Filter Not Factory-Installed)
Please replace or clean the filter regularly, as dust can gradually accumulate onto the surface of the filter
after a long period of time.
Follow these steps to properly replace the filter:
After removing the two manual bolts, take down the filter
cover and pull out the filter from the case, then insert the
new one into the case along the filter rail. Finish by fixing
the filter cover with manual bolts.
4
Air Filter
Filter Rails
Filter Cover
Manual Bolt
Model Filter size (LxWxH)
in.
24K/36K 20x18x1
48K/60K 22x20x1
Air Filter

Installation and Maintenance
1. Safety Notice and Tips
WARNING
• Install the air conditioner on a solid base that can support the unit's weight. (An inadequate base or incomplete
installation may cause injury, due to falling off from the base.)
•Electrical work should be carried out in accordance with the installation manual and the local and national
electrical wiring rules or codes.
(Insufficient capacity or incomplete electrical work may cause electrical shock or fire.)
• Be sure to use a dedicated power circuit. (Never use a power supply shared by another appliance.)
• For wiring, use a cable long enough for the entire distance, and do not use an extension cord.
• Do not put other loads on the power supply, and ensure a dedicated power circuit is used.
• Use the specified types of wires for electrical connections between the indoor and outdoor units. (Firmly clamp
the interconnecting wires so that the terminals receive no external stress.)
• Incomplete connections or clamping may cause terminal overheating or fire.
• After establishing connection between all the wires, secure the cables to prevent undue force on the electrical
covers or panels. (Install covers over the wires. Incomplete cover installation may cause terminal overheating,
electrical shock, or fire.)
• There is 100PSIG of high pressure nitrogen in the evaporator, that must be released it first before installation.
It indicates that the evaporator is sealed if nitrogen escapes, otherwise, it can indicate an evaporator leak.
• When installing or relocating the system, be sure to keep the refrigerant circuit free from air (Air in the
refrigerant circuit may cause an abnormal pressure rise or rupture, resulting in injury or damage.
• If any refrigerant leakage occurs during the installation work, ventilate the room liberally.
• After all installation is completed, ensure that no refrigerant leaks. (The refrigerant can produce toxic gas if
exposed to flames.)
• When carrying out piping connections, do not allow air substances other than the specified refrigerant to enter
the refrigeration cycle, else it can cause decreased performance, abnormally high pressure in the refrigeration
cycle, explosion, and injury.)
• Ensure that the installation has a proper ground-earth connection. Do not ground the unit to a utility pipe,
arrester, or telephone grounding. Incomplete grounding may cause electrical shock. (A high surge current from
lightning or other sources may cause damage to the air conditioner.)
• An earth leakage circuit breaker may be required depending on the site condition, to prevent electrical shock.
• Disconnect the power supply before wiring, piping, or checking the unit.
2. Installation of the Indoor Unit
2.1 Initial Check
·When moving the unit after unpacking, exercise caution to not exert any pressure on other parts,
especially the refrigerant piping, drain piping and flange parts.
·Wear personal protective equipment when installing the unit.
CAUTION
>0
>0>0
≥25
≥40 ≥40
Front of Unit
Clearance in the Vertical Position Clearance in the Horizontal Position
Air Inlet
(Unit:in.)
Air Outlet
5

Installation and Maintenance
NOTE:
These appliances are designed for indoor
installation only.
The indoor units can be installed in one of the
upright, horizontal left, or horizontal right
orientations as shown in the Figures below.
Minor field modifications are necessary to
convert to horizontal left.
2.2 Installation Location
2.3 Installation
2.3a: Upflow Installation
Before selecting the installation site, obtain all required
permissions and follow the below parameters:
·Optimal air distribution is ensured.
·The air path is not blocked or obstructed.
·Condensation is able to drain properly.
·Ensure sufficient clearance for future maintenance and servicing.
·Piping between the indoor and outdoor units should be within the
allowable limits. (Refer to the installation of the outdoor unit
manual)
·The indoor unit, outdoor unit, power supply wiring, and
transmission wiring should be kept at least 3 feet away from
televisions and radio, which prevents image interference and
noise in those electrical appliances.(Noise may be generated
depending on the conditions under which the electric wave is
generated, even if this distance is maintained.)
·Do not install the indoor unit in a machinery shop or kitchen
where vapors from oils or any mists can reach the indoor unit.
Any oils will collect on the heat exchanger, thereby reducing the
performance of the indoor unit, and may deform, and in the
worst case, break the plastic parts of the indoor unit.
·When the unit is installed in a hot and humid place, it is
recommended to insulate the cabinet exterior and to use
auxiliary drain pans.
·If installed above a finished living space, an auxiliary drain
pan(as required by many building codes) must be installed under
the entire unit, and its condensate drain line must be routed to a
location such that the user will see the condensate discharge.
6
The upright installation method is selected by default.
When the unit is horizontal-right mounted, rotate it to
the right by 90 degrees, as shown in the image for
horizontal-right installation (2.3b).
When the unit is horizontally-left mounted (2.3c), the
following steps are required.
1). Disassemble the lower panel and the sealed plate.
2). Disassemble the retaining clips for the evaporator
so that the evaporator can be pulled out along the
lead rail easily.
3). Rotate the evaporator by 180 degrees and insert it
into the upper side of the lead rail.
4). Rotate the unit to the left by 90 degrees, as shown
in the image "2.3b: Horizontal-Left Installation".
5). Reinstall the sealed plate and the lower panel.
2.4 Air Duct
Field duct work must comply with the National Fire
Protection Association NFPA 90NFPA 90B, and any
applicable local ordinances.
Do not, under any circumstances, connect return duct
work to any other heat producing device such as a
fireplace insert, stove, etc. Unauthorized use of such
devices may result in fire, carbon monoxide poisoning,
explosion, personal injury or property damage.
WARNING
Drain Piping Auxiliary Drain Pan
Auxiliary Drain Pan
Drain Piping
Evaporator
Lower Panel and
Sealing Plate
2.3b: Horizontal Right Installation (or hanging from ceiling)
2.3c: Horizontal Left Installation (or hanging from ceiling)

Remove !he
S
crews
Remove !he
F
an
I
S
(
3. OPTIONAL: Downflow Conversion Instructions
7
N
Installation and Maintenance