1
Ethernet AVB Network Audio
E64i/o-MADI Quick-Start Guide
Pivitec, LLC
116 Research Drive, Ste 138
Bethlehem, PA 18015, USA

2
READ THIS FIRST
Important Safety Instructions
Read these instructions.
Keep these instructions
Heed all warnings.
Follow all instructions.
Do not use this apparatus near water.
Clean only with a dry cloth.
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that
produce heat.
Do not defeat the safety purpose of the polarized or grounding‐type plug. A polarized plug has two blades with one wider
than theother. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong is
provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the
obsolete outlet.
Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point
where they exit the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a
cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip‐over.
Unplug this apparatus during lightning storms or when unused for long periods of time.
Refer all servicing to qualified personnel. Servicing is required when the apparatus has been damaged in any way, such as
when the power‐supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
No on/off power switches are included in the system. The external power supply should be used to control power to a
Pivitec, LLC device. This power supply should remain readily operable.

3
WARNING!
TO REDUCE THE DANGER OF ELECTRICAL SHOCK DO NOT REMOVE COVERS. NO USER
SERVICEABLE PARTS INSIDEREFER SERVICING TO QUALIFIED SERVICE PERSONNEL
ONLY
To reduce the risk of fire or electrical shock, do not expose this product to rain or other types of moisture.
To avoid the hazard of electrical shock, do not handle the power cord with wet hands.
CAUTION:
Using any audio system at high volume levels can cause permanent damage to your hearing.
Set your system volume as low as possible.
Avoid prolonged exposure to excessive sound pressure levels.
IMPORTANT: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to the product not expressly approved by Pivitec, LLC could void the user’s
FCC authority to operate the equipment.

4
Warranty
Pivitec, LLC warrants this product against defects in materials and workmanship for a period of one year from the date of the
original retail purchase.
This warranty does not apply if the equipment has been damaged due to misuse, abuse, accident, or problems with electrical
power. The warranty also does not apply if the product has been modified in any way, or if the product serial number has been
damaged, modified, or removed.
If a defect is discovered, first write or call Pivitec, LLC to obtain a Return Authorization number. No service will be performed
on any product returned without prior authorization. Pivitec, LLC will, at its option, repair or replace the product at no charge
to you. The product must be returned during the warranty period, with transportation charges prepaid to Pivitec, LLC, 116
Research Drive, Bethlehem, PA 18015, USA. You must use the product’s original packing materials for shipment. Shipments
should be insured for the value of the product. Include your name, address, phone number, description of the problem, and
copy of the original bill of sale with the shipment. The Return Authorization number should be written on the outside of the
box.
THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS, WHICH
VARY FROM STATE TO STATE (OR JURISDICTION TO JURISDICTION). PIVITEC'S RESPONSIBILITY FOR
MALFUNCTIONS AND DEFECTS IN HARDWARE IS LIMITED TO REPAIR AND REPLACEMENT AS SET
FORTH IN THIS LIMITED WARRANTY STATEMENT. ALL EXPRESS AND IMPLIED WARRANTIES FOR THE
PRODUCT, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO THE WARRANTY PERIOD SET
FORTH ABOVE. NO WARRANTIES, WHETHER EXPRESS OR IMPLIED, WILL APPLY AFTER SUCH PERIOD.
PIVITEC, LLC DOES NOT ACCEPT LIABILITY BEYOND THE REMEDIES SET FORTH IN THIS LIMITED
WARRANTY DOCUMENT. PIVITEC, LLC’S LIABILITY IS LIMITED TO THE REPAIR OR REPLACEMENT, AT
OUR OPTION, OF ANY DEFECTIVE PRODUCT, AND SHALL IN NO EVENT INCLUDE INCIDENTAL OR
CONSEQUENTIAL DAMAGES OF ANY KIND.
SOME STATES DO NOT ALLOW EXCLUSIONS OR LIMITATION OF IMPLIED WARRANTIES OR LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO
YOU.

5
Quick Start guide for the e64i/o-MADI for PMM systems
The Pivitec e64i/o-MADI is a bi-directional 64-channel MADI to Ethernet AVB Bridge. The e64i/o-MADI
will bi-directionally bridge signals from MADI sources such as mixing consoles, microphone preamps,
Analog to Digital converters, AVB Capable computers, and DAW interfaces. Ideal for use in
applications such as broadcast, live performance and recording, multiple e64i/o-MADI Bridges can be
combined together or used with other Pivitec Network Audio Interface Modules to build larger audio
networks.
The e64i/o MADI can connect a MADI enabled Mixer directly into an AVB capable Apple MAC
computer, with up to 64 tracks recorded and played back. Minimum requirements are:
Apple Computer with:
1). Thunderbolt port.
2). OS X 10.10 Yosemite or higher.
Front
The front panel of the e64i/o MADI has indicators for system status:
1). When on, unit is powered.
2).When on, indicates a MADI signal is present at the Coaxial input.
3). When on, indicates a MADI signal is present at the Optical input.

6
Rear
The Rear panel for the e64i/o MADI has all connections:
4). MADI Optical In and out on a SC Multi-Mode Fiber Connector.
5). MADI Coaxial In an Out on 2 BNC connectors.
6). RJ-45 Network connection.
7). Jack for an external 48VDC Power supply, used only if the e64i/o MADI is not powered by a
suitable POE switch.
Use only the 48VDC Power Supply provided by Pivitec!
Setup
The Pivitec 64i/o-MADI will support full 64 channel in and out simultaneously. Also what appears in
the currently used input connection appears on both MADI Coaxial and Optical outputs.
Using the e64i/o-MADI as a recording bridge.
The e64i/o-MADI will connect a MADI audio source, such as an audio console, to an AVB Recording
device, such as an Apple Mac Computer. Properly set up the MADI stream Sample Rate to 48k or 96k,
and make those setting changes in the e64i/o-MADI as described below with the AVDECC controller.
Using the e64i/o-MADI with a Pivitec Personal Monitor Mixing system

7
The e64i/o-MADI can be used with a managed Non-AVB switch for Personal Monitor Mixing as long as
the switch has an available Gigbit Port. The ability to record directly off of the system is not available
with this option. Set up your Pivitec system as shown in the Pivitec Quick Start Guide .
Although the e64i/o MADI is capable of transmitting four 16 channel audio streams, the e32 Mixer
with the V2MIX-Pro app can accept only 2 of these streams. Default selection would be 1-16 and 17-
32. To select the higher streams, use the Pivitec AVDECC controller. The controller may be
downloaded here. AVDECC Controller.
Run the AVDECC Controller application. The application works over Wi-Fi and Wired Ethernet.
Choose the network interface that is connected to the network:

8
Next, Press Refresh Streams.

9
The devices in the network will appear as Talkers and Listeners, with Talkers being a source, and
Listeners being a destination. You will notice that the e64i/o MADI is bidirectional, so it appears as
both a Talker and a Listener. Select the e64i/o MADI talker, and the e32 Mixer listener.

10
The Output Stream and Input Stream will populate:
Indice
Manuali Router di rete popolari di altre marche

NETGEAR
NETGEAR FS526T - Switch Manuale utente

Korenix
Korenix JetNet 5710G Series Manuale utente

Automated Logic
Automated Logic ZN551 Manuale del proprietario

Cisco
Cisco ASR 1000 Series Manuale dell'operatore

EnGenius
EnGenius ESR-9710 Manuale utente

Cisco
Cisco 805 Series Istruzioni operative e di sicurezza