Planika FKE-0683 Foglio di istruzioni

www.planikafires.com i0776#01 30.04.2014 1
Configuration of the module with Wi-Fi and Smart Home System manual
This manual allows to configure the module in order to control the bio fireplace b means of:
1. The device that has access to Wi-Fi (smartphone, tablet) – THE CONFIGURATION OF Wi-Fi
and SMARTPHONE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. Smart Home S stem – SMART HOME SYSTEM CONNECTION . . . . . . . . . . . . . . . . . . . . 5
1. THE CONFIGURATION OF WiFi and SMARTPHONE
The configured appliance will allow to:
-Turn on the product (if READY message on displa )
-Turn off the product (for COOLING THE DEVICE or READY message on displa )
-Make the flame size lower or higher while the bio fireplace is working
-Turn on/turn off ‘Lock the device’ function (Customer’s Menu, point 1)
-Choose the bio fireplace which is to be controlled.
It will be also possible to check the serial number, program version, website version and total operating
time.
FLA 3 communicates with the exterior appliances b means of Wi-Fi.
Make sure that Wi-Fi network ou have is of 802.11 b/g/n standard and it operates the encr ption of
WPA/WPA2 PSK.
If our Wi-Fi network does not fulfill the above mentioned requirements it has to be adjusted.
Otherwise, remote controlling of the bio fireplace via the appliance will not be possible.
If Wi-Fi network is read , prepare the formatted USB flash drive.
Create a text file on USB flash drive with the name ‘wifi’ and ‘txt’ extension.
Save the name of the network and password in the file in a given format, where:
Instead of ‘Wi-Fi Network name’ – enter the name of the network, e.g. ‘home’
Wi-Fi Network Password – password to the network, e.g. ‘m net’
Example:

www.planikafires.com i0776#01 30.04.2014 2
Make sure that the bio fireplace is disconnected from the mains then put USB flash drive to USB port
on the side part of the product.
Connect the bio fireplace to the mains and wait min. 5 minutes. USB flash drive ma be disconnected
and the product ma be turned on with button.
Hold ‘+’ for 8 seconds and ‘Customer’s menu’ will appear [p. 10 in User’s manual]. Press ‘+’ to go to
point 4 ‘Device IP’ and confirm b pressing ‘-‘.
Product’s IP needed for the operation via the configured appliance will be visible then. Correct IP
format is: 192.168.XXX.XXX .
It ma happen that the displa ed IP is incorrect. In such case follow the instructions below.
0.0.0.1
No communication with the module
at all
It is normal during the
initialization of the
product. If it does not disappear after several
minutes after turning on the bio fireplace,
begin to format USB flash drive again.
0.0.0.2
No connection with the network
(wrong data / IP is bus / no network)
Follow the procedure of giving the network
parameters once more – install USB flash
drive again.
0.0.0.3
Text mode
–
jumper was not
downloaded
Follow the procedure of giving the network
parameters once more – install USB flash
drive again. Call SERVICE.
127.0.0.1
No connection with the network
(wrong data / IP is bus / no network)
Follow the
procedure of giving the network
parameters once more – install USB flash
drive again.
WARNING! There is possibilit to check the reason of configuration failure. To do this read the file
‘wifi.txt’.
Network parameters changed
The change of all the net
work parameters was successful
Error 0x01
Interfaces error (call service)
USB

www.planikafires.com i0776#01 30.04.2014 3
Data changed successfull
The change of network password or
network
name was
successful
Incorrect data format
Data
incorrectl entered
into the file (save data again on
USB
flash drive, if it does not work, format USB flash drive or use a
different one)
If the displa ed IP number is correct one, save it.
The mobile appliance should be connected to the configured Wi-Fi network. The operation of bio
fireplace via website was tested with the following browsers:
Windows: Opera, Firefox, Chrome, IE min 11
Android: Firefox, Chrome, Opera Browser, Opera Classic, Safari
Apple - Safari, Chrome
In the address bar enter the saved IP address and download the webpage.
The displa will appear on the appliance:
Due to SETTINGS function it is possible to determine:
-Serial number
-Displa and microprocessor’s program version
Allows to give an
name of the appliance
to facilitate choosing it
from the list of
different appliances.
Activates ‘Lock the
device’ function (see:
User’s manual -> III
Customer’s menu -> 1.

www.planikafires.com i0776#01 30.04.2014 4
-total time of the product operation
-website version
Thanks to MANAGE function it is possible to control unlimited number of configured bio fireplaces.
If Wi-Fi network has access to the Internet, it is possible to enter www.planikafires.com or
www.fireline.planikafires.com/fla
WARNING!
To control the bio fireplace, it needs to be installed according to the Installation Manual. The user has
to be familiar with the User’s Manual. Onl after the configuration it is permitted to turn on the product
for the first time.

www.planikafires.com i0776#01 30.04.2014 5
2. SMART HOME SYSTEM CONNECTION
When Smart Home S stem driver installed it is possible to control the bio fireplace when it comes to:
-Turning on the product (if READY message on displa )
-Turning off the product (if COOLING THE DEVICE or READY message on displa )
-Making the flame size lower or higher while the bio fireplace is working
It is possible to see the current mode of the product on the Smart Home S stem control panel:
-read to start (message READY)
-working (message WORKING)
-lack of fuel (message NO FUEL)
-waiting for an occurrence (message WAITING or COOLING THE DEVICE)
-ERROR XX.
The description of Smart Home S stem ports
Description of electrical connectors
GND – COM DC -V
STA T – 12 DC +V input initializing the bio fireplace, signal as an impulse lasting 100ms up to 1s
STOP – 12 DC +V input turning off the bio fireplace, signal as an impulse lasting 100ms up to 1s
UP – 12 DC +V input increasing the flame, signal as an impulse lasting 100ms up to 1s
DOWN – 12 DC +V input decreasing the flame, signal as an impulse lasting 100ms up to 1s
A – EADY – transmitter output signaling that the device is read
information
control
GND COM DC
-
V
START
STOP
UP
DOWN
INPUT
12-24
VDC
A
B
C
D

www.planikafires.com i0776#01 30.04.2014 6
B – WO KING - transmitter output signaling that the device is working
C – FUEL – transmitter output signaling lack of fuel
D – E O – transmitter output signaling error / other
A+B – transmitter output
All the ports have been adjusted to work within the voltage of 12V – 24V of the direct current. Higher
voltage requires the use of additional limiter installed on the module’s port.
There is possibilit to control a few bio fireplaces simultaneousl . In order to do so, it is essential to
divide the signal into several ones, one per each product.
Scheme
Description:
Input – voltage port 12V – 24V of the direct current.
OUTPUT - voltage port 12V – 24V of the direct current depending on the mode of the bio fireplace.
Chart with the signals that ma occur depending on the bio fireplace mode.
1 – port where the signal is
0 – lack of the signal in the port
A
B
C
D
READY
1
0
0
0
WORKING
0
1
0
0
FUEL
0
0
1
0
ERROR
0
0
0
1
WAIT/COOLING
1
1
0
0

www.planikafires.com i0776#01 30.04.2014 7
Mode of operation
After connecting according to the scheme above, controlling of the bio fireplace takes place via
emitting single and short electrical impulses (lasting from 100ms to 1s) to the electrical connectors. A
single impulse directed to START port leads to turning on the bio fireplace (when stand-b mode is
activated manuall with button).
A single impulse directed to STOP port leads to switching the bio fireplace into stand-b mode.
A single impulse directed to UP port increases flame size b one level.
A single impulse directed to DOWN port decreases flame size b one level.
Electrical connector READY indicates that the bio fireplace is read to start.
Electrical connector WORKING indicates that the bio fireplace is working. Disappearance of the signal
is equal to turning off the product or lack of fuel.
Electrical connector FUEL indicates lack of fuel.
Electrical connector ERROR indicates an errors of the product (in order to identif what happened
one needs to have a look at the fireplace displa ).
Electrical connector READY + WORKING indicates initialization or cooling of the bio fireplace.
Disappearance of this signal is equal to switching into READY mode or other mode visible on the
displa .
Altri manuali Planika Bruciatore

Planika
Planika Simple Manuale utente

Planika
Planika Prime Fire 590 Manuale utente

Planika
Planika Cabo Manuale utente

Planika
Planika Totem Manuale utente

Planika
Planika KL21 Rio Manuale utente

Planika
Planika Dancing Flames Manuale utente

Planika
Planika Hot Box REMOTE Manuale utente

Planika
Planika Pure Flame Manuale utente

Planika
Planika FLA 2 E 4 Manuale utente

Planika
Planika KL21 Square Manuale utente