Polycom RMX 1500 Istruzioni per l'installazione

Polycom
®
RMX
®
1500
Hardware Guide
Version
7.2.2
|September 2011 |DOC2618C

Trademark Information
Polycom®, the Polycom “Triangles” logo, and the names and marks associated with Polycom’s
products are trademarks and/or service marks of Polycom, Inc., and are registered and/or
common-law marks in the United States and various other countries.
All other trademarks are the property of their respective owners.
Patent Information
The accompanying product may be protected by one or more U.S. and foreign patents and/or
pending patent applications held by Polycom, Inc.
© 2011 Polycom, Inc. All rights reserved.
Polycom, Inc.
4750 Willow Road
Pleasanton, CA 94588-2708
USA
No part of this document may be reproduced or transmitted in any form or by any means,
electronic or mechanical, for any purpose, without the express written permission of Polycom, Inc.
Under the law, reproducing includes translating into another language or format.
As between the parties, Polycom, Inc., retains title to and ownership of all proprietary rights with
respect to the software contained within its products. The software is protected by United States
copyright laws and international treaty provision. Therefore, you must treat the software like any
other copyrighted material (e.g., a book or sound recording).
Every effort has been made to ensure that the information in this manual is accurate. Polycom,
Inc., is not responsible for printing or clerical errors. Information in this document is subject to
change without notice.

Polycom RMX 1500 Hardware Guide
i
Table of Contents
Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
Main Features .......................................................................................... 1-1
RMX 1500 Specifications ....................................................................... 1-2
RMX 1500 System Capacities ................................................................ 1-3
Conferencing Capacities ........................................................ 1-3
Resource Capacities ................................................................ 1-5
Site Requirements ................................................................................... 1-6
Safety Requirements ...................................................................... 1-6
Rack Mount Safety Precautions .................................................... 1-6
Installation Precautions ................................................................. 1-7
Installing the RMX 1500 ................................................................. 1-8
Unpacking the RMX 1500 ...................................................... 1-8
Mounting the RMX 1500 in a Rack ...................................... 1-9
Connecting the RMX 1500 to a Power Source .......................... 1-10
Connecting the RMX 1500 to AC Power ........................... 1-11
Connecting Cables to the RMX 1500 .......................................... 1-12
First-time Power-up ..................................................................... 1-13
RMX 1500 Components ....................................................................... 1-14
RMX 1500 Front Panel ................................................................. 1-14
Opening the RMX 1500 Front Panel .................................. 1-14
Front Panel Components ..................................................... 1-15
RMX 1500 Rear Panel ................................................................... 1-16
RTM IP 1500 .......................................................................... 1-16
RTM ISDN 1500 .................................................................... 1-18
ISDN/PSTN Clock Source .................................................. 1-19
RMX 1500 Power Supply ............................................................. 1-20
Power Supply LEDs ............................................................. 1-20
RMX 1500 LEDs .................................................................................... 1-21
RMX 1500 Front Panel LEDs ....................................................... 1-21
RMX 1500 Rear Panel LEDs ........................................................ 1-22
RTM IP 1500 LEDs ................................................................ 1-22
RTM ISDN 1500 LEDs .......................................................... 1-24

Table of Contents
Power Supply LEDs ............................................................. 1-24
Component Installation & Replacement . . . . . . . . . . . . . . . 2-1
Installing a New RTM ISDN 1500 Card .............................................. 2-1
Replacing the RTM ISDN 1500 ............................................................. 2-3
Pin Assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
PRI Port Assignment ............................................................. A-1

1-1
1
Hardware Description
This Hardware Guide provides information on the RMX 1500 and its
components. This system utilizes a modular platform, whose
components are designed for high performance, capacity and reliance.
Main Features
The Polycom RMX 1500 offers the following features:
•Linux®based
• Support for standard network interfaces (H.323, SIP video, ISDN,
PSTN and LAN)
• New hardware technologies
• Telco grade high availability, on-line upgrading and dynamic
resource allocation
• Easy integration of conference elements into external network
management
• Enhanced Continuous Presence (multi-image video)
• IVR (Interactive Voice Response) module

Chapter 1-Hardware Description
1-2
RMX 1500 Specifications
Table 1-1 Polycom RMX 1500 Specifications
Physical
Height 1U (4.44 cm.)
Width 19” (48.26 cm.)3
Depth 23.6” (60 cm.)
Weight Up to 12 Kg.
Media Protocols
Audio G.711, G. 719, G.722, G.722.1, G. 728, G.729A,
G.723.1, Siren14, Siren 22.
Video H.261, H.263, H.264.
Network Interfaces
IP, ISDN, PSTN and LAN H.323, SIP, ISDN, PSTN and LAN
Power Supply
AC Input/ Range, BTU Voltage range: 100-240 VAC ±10%, 47-63 Hz.
Maximum BTU output: 3400 per hour.
Power Consumption
AC Maximum Power
consumption 350 Watts.
Environment
Operating temperature 0°– 40°C (22°– 104°F).
Storage temperature -40°– 70°C (-40°– 158°F).
Relative humidity 15% - 90% no condensing.
Operating altitude Up to 4,500 m (15,000 ft.).
Operating ESD 4 kV.

Polycom RMX 1500 Hardware Guide
1-3
RMX 1500 System Capacities
Conferencing Capacities
The following table summarizes the different system capacities.
Table 1-2 System Functions and Capacities RMX 1500 Series
System Functions MPMx - Q MPMx -S MPMx -D
Maximum number of Video participants
in a conference 25 45 90
Maximum number of PSTN participants
in a conference 90 120 120
Maximum number of VOIP participants
in a conference 90 180 360
Maximum number of Audio calls per
second 555
Maximum number of Video calls per
second 222
Maximum number of conferences 200 400 400
Maximum number of Meeting Rooms 1000 1000 1000
Maximum number of Entry Queues 40 40 40
Maximum number of Profiles 40 40 40
Maximum number of Conference
Templates 100 100 100
Maximum number of SIP Factories 40 40 40
Maximum number of IP Services 2 2 2
Maximum number of ISDN Services 2 2 2
Maximum number of IVR Services 40 40 40
Maximum number of Recording Links 20
(default) 20
(default) 20
(default)
Maximum number of IVR Video Slides 150 150 150

Chapter 1-Hardware Description
1-4
Maximum number of Log Files (1Mb
max.) 4000 4000 4000
Maximum number of CDR Files 2000 2000 4000
Maximum number of Fault Files 1000 1000 1000
Number of Participant alerts Unlimited Unlimited Unlimited
Maximum number of concurrent RMX
Web Client connections to the MCU 20 20 20
Maximum number Address Book entries 4000 4000 4000
Maximum number of Users 100 100 100
Maximum number of Gateway Profiles 40 40 40
Maximum number of Reservations
(internal Scheduler) 2000 2000 2000
Table 1-2 System Functions and Capacities RMX 1500 Series
System Functions MPMx - Q MPMx -S MPMx -D

Polycom RMX 1500 Hardware Guide
1-5
Resource Capacities
* Capacity numbers may be lower when LPR and/or Encryption are enabled.
Table 1-3 System Resource Capacities per Resolution in CP Mode
Resource Type/
Video Resolution MPMx - Q MPMx -S MPMx - D
CIF H.263 14 30 60
CIF 30 H.264 25 45 90
CIF 60 H.264 14 30 60
SD 30/ 4CIF H.264 14 30 60
4CIF H.263 715 30
720p30/ 4CIF 60/
SD 60 715 30
1080p30fps/720p60 3 7 15 (Symmetric)
VOIP 90 180 360
PSTN 90 120 120
ISDN 25 60 (at 128 Kbps)
- 4 E1/T1 60 (at 128 Kbps)
- 4 E1/T1
On the RMX1500 with a MPMx-Q media card, the use of HD resolution with
Continuous Presence requires an additional license.
Table 1-4 System Resource Capacities per Line Rate per Card Type in VSW
Audio/Video and
Resolution MPMx - Q MPMx - S MPMx -D
VSW 2Mb 20* 40* 80*
VSW 4Mb 10 20 40
VSW 6Mb 510 20
ISDN 25 (at 128 Kbps) 60 (at 128 Kbps) 60 (at 128 Kbps)

Chapter 1-Hardware Description
1-6
Site Requirements
This section describes the requirements your site must meet for safe
installation and operation of the system.
Safety Requirements
For your protection, please read these safety instructions completely
before operating the equipment.
• Look carefully for potential hazards in your work area: moist floors,
ungrounded power cables, frayed power cords, missing safety
grounds and so forth.
• Locate the main circuit breaker within the room.
• Locate the emergency power OFF switch within the room.
• Never assume that power is disconnected from a circuit.
• Use only the power cord supplied with the system.
• The power cord should only be connected to a power outlet that has a
protective ground contact.
• Ensure that the power cord is easily accessible from the back of the
system at all times.
• Place the equipment in a well-ventilated area where the vents are free
from obstruction.
• Do not place heavy objects directly on top of the RMX 1500 unit.
• Do not use liquids around your equipment.
Rack Mount Safety Precautions
The following precautions should be followed with regards to rack mount
safety:
• Keep the area around the RMX 1500 clean and free of clutter.
• Decide on a suitable location for the equipment rack that will hold the
RMX 1500 unit. It should be situated in a clean, dust-free area that is
well ventilated. Avoid areas where heat, electrical noise and
electromagnetic fields are generated. You will also need it placed
near a grounded power outlet.
• Ensure that the leveling jacks on the bottom of the rack are fully
extended to the floor with the full weight of the rack resting on them.
Altri manuali per RMX 1500
10
Indice