Problem
Pump
stops
working or
runs slow
Pump will
not prime.
Pump loses
prime
Possible Cause
Bad Power supply
Internal Thermal
Protector enabled
Impeller is locked
with debris
Too much debris,
Intake clogged
Air trapped in
impeller chamber.
Impeller worn out
Pump design is
NOT self-priming
Air leak
Power interruption
Solution
Check all power connections,GFCI and circuit breakers.
Test using a different power source.
Unplug and allow Pump to cool 30 minutes.Check if Pump is
clogged before restarting.
Disconnect power and use a pencil eraser to see if Impeller can be
turned.If not, perform impeller maintenance.
Disconnect power and remove the obstruction.
Use a Pondmaster Pump Bag to reduce future clogging.
Turn off Motor and restart after a few seconds.Repeat three times.
Replace with a new Impeller.
Position Pump below water level or fill hose with water and re-start.
Check intake tubing and connections then repair air leak.
Use a Check Valve to avoid losing prime when power is interrupted.
Troubleshooting:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Intake Strainer
Motor Cover
Rubber Seal
Impeller
Impeller Plate
Rotor
Motor Support / Handle
Motor
Screws
1.5”Connector
2 Step 1.5”Barbed Connector
2”Connector
2 Step 2”Barbed Connector
2”to 1.5”Reducer
1.5”Directional Coupling
Motor Cover Screw
# Description
WARNING RISK OF ELECTRIC SHOCK
This pump is supplied with a grounding conductor and grounding type
attachment plug. NEVER REMOVE GROUND PIN FROM PLUG.To reduce the risk of
electric shock, be certain that it is connected only to properly grounded, grounding-type
receptacle. The national Electric Code requires that a ground fault interrupter circuit
(GFCI) be installed in every branch circuit supplying the fountain or pond equipment.
Your dealer can supply GFCI units.
Do not immerse the plug in water. DO NOT REACH INTO THE WATER TO REMOVE THE
PLUG.TURN OFF CIRCUIT FIRST. A "drip loop" in the cords should be used. A "drip loop" is
a loop in the cord below the level of the receptacle or plug that prevents water from
traveling along the cord.
WARNING: FOR YOUR PROTECTION, ALWAYS UNPLUG THE UNIT FROM ITS POWER SOURCE
BEFORE INSTALLING OR SERVICING. DO NOT REACH, REMOVE OR DISASSEMBLE BEFORE YOU
DISCONNECT POWER.
Thank you for purchasing this Pondmaster product.This Continuous Duty Pump is designed
to move large volumes of water silently and efficiently through filtration systems or to a
waterfall, stream or fountain. It incorporates a single-phase capacitor asynchronous motor, a
high efficiency vortex Impeller in conjunction with a ceramic impeller shaft and bearings to
save energy while maintaining high output.
This Pump can be used immersed or inline. Note that when used inline it should be placed
below the water level since it is not self-priming. Never run this Pump dry.
WARNING! PONDS ARE DANGEROUS TO SMALL CHILDREN!
NEVER LEAVE CHILDREN UNSUPERVISED NEAR A POND.
MODELS ITEM#
WFP
1900 20210
WFP
2550 20215
WFP
4850 20220
WFP
6100 20225
WFP
6600 20230
SAVE THESE
INSTRUCTIONS
CARE AND OPERATING INSTRUCTIONS
NOTE: Parts vary on different models.
When referencing pump parts
you must refer to the ITEM # of
your pump from pump label.
Please write your ITEM # here:
PARTS LIST for Pond & Waterfall Pumps
Model 1900 2550 4850 6100 6600
Item # 20210 20215 20220 20225 20230
DANNER MFG. INC. • Islandia, New York 11749-1489 • Visit our web site at www.dannermfg.com
Pond and Fountain Pump with HY-Drive Technology
ZG282 9/10
LIMITED WARRANTY E.G. Danner Mfg. Inc. will repair or replace any unit found to be
defective within three years of original purchase.This warranty covers defects occurring under
normal use and applies to the original purchaser at retail from a certified Pondmaster dealer and
may not be transferred. Cutting or altering cord removing or defacing product labels voids any
warranty consideration. For warranty repair return only the part that is defective to our factory.
Please include $10.00 for postage and handling. Damages or injuries resulting from negligence,
shipping, handling, improper installation, maintenance or misuse of the product are not covered
by warranty.This warranty gives you specific legal rights.You may have other rights which vary
from state to state.
To validate this warranty, include your dated proof of purchase (copy of sales receipt from a
certified Pondmaster dealer).

MAINTENANCE: KEEP IMPELLER CLEAN
This Pump does not require any lubrication or special maintenance. Periodically cleaning the
impeller will maintain Pump performance and extend Pump life.
1) Completely disconnect Pump from power supply.
2) Remove hoses and bring Pump to clear work area.
3) To remove Intake Strainer, unscrew bottom screw (if included with your Pump model) .
Press sides in to release side hooks and slide off Intake Strainer .
4) Remove 4 screws to detach Motor from Motor Support /Handle and Motor Cover.
5) Pull the Impeller out from the chamber . If impeller is difficult to remove, calcium or scale
deposits may have seized parts together. Place unit in a bucket with a solution of 1 part white
vinegar to 9 parts water and allow to soak overnight.This should loosen scale for disassembly.
6) Clean impeller, impeller chamber and Intake Strainer with fresh water or vinegar solution
only, never any solvents.
7) Reverse steps to reassemble. If rubber seal becomes dislodged, make certain it is clean
and place it back into the recess on the Motor housing.
8) Align the Impeller plate with the recess in the Motor Cover before inserting Impeller back
into Motor.
OPERATION PRECAUTIONS
Never run Pump dry.
Only use this Pump with clean water. It is not intended to move water containing large
non-dissolved solids. Never use Pump for liquids other than water.
Do not place directly into silt or sand. Seat on a flat solid surface or mount using
mounting holes on Motor Support / Handle.
Do not use in hot water over 40 degrees C.
Do not touch Impeller if Pump is plugged in.Thermal Protector may have temporarily
turned off Motor, which will turn back on after cooling.
Never use Pump if power cord is cut or damaged in any way.
Cord can not be changed. If damaged, Pump must be discarded.
If motor is clogged, disconnect power to prevent damage to Pump until it can be
serviced.
OPERATING INSTRUCTIONS
Pump can be used either IMMERSED or IN-LINE
For all installations: Make certain that all electrical connections have a GFCI installed.
Always use Teflon tape on hose fittings.This will aid in future disassembly.
Immersed Application:
Protect the intake from
leaves and other debris
getting drawn into the
Impeller by using a
separate Pump Bag or
by placing Pump into a
Skimmer or Pump Vault.
Minimum depth from top
is 6”(15 cm) to prevent air
from getting drawn in.
In-line Application:
Remove Intake Strainer to
connect to Pump inlet.
Place Pump below water
level, otherwise it will be
necessary to prime it. To
prime Pump, hoses must
be filled with water before
activating Pump.
A separate in-line check valve or foot valve is strongly recommended to prevent loss of
prime if power is interrupted.
Cut off any extra
small sections
that restrict
flow rate.
WINTERIZATION and STORAGE
If Pump is used outdoors in areas with harsh winters the Pump should be removed from shallow
water that may freeze. Either place Pump into deep water or if Pump is removed, it must be
cleaned with plain water and dried before being put into storage.
If Pump will be turned off for long periods of time and left under the water in non-freezing areas,
debris may accumulate inside the pump. Before reinstallation Pump should be flushed with
clean water. It is strongly recommended to perform an Impeller maintenance to thoroughly clean
the Impeller and chamber before storing.
Rotate top
to change
direction
Remove
Bottom Screw
(on some models)
Note:
Directional
Coupling is
not for use
out of water.
0’ 1’ 3’ 5’ 7’ 10’ 15’ 20’ 25’ 30’
HY-DRIVE
MODEL
ITEM #
WATTS / 0’
AMPS
SHUTOFF
HEIGHT (FT)
SHUTOFF
WATTS
GALLONS PER HOUR
1900
2550
4850
6100
6600
WFP
WFP
WFP
WFP
WFP
20210
20215
20220
20225
20230
147
93
328
520
593
1.25
.78
2.76
4.39
4.94
1910
2505
4850
6100
6625
1710
2380
4725
5750
6600
1325
2010
4300
4725
6275
870
1490
3700
4175
5500
555
1045
3050
3450
4925
455
2225
2400
4325
1550
1625
3325
300
850
2425
250
1850 550
10
11.5
22.5
28
30.5
90
135
300
425
445
PUMP
CHART
B
B
A
C
E
D
F
WATERFALL BOX
PUMP
Remove Intake Strainer
for In-line use
. 6”
(15 cm)
A
B
CD
E
F
Questo manuale è adatto per i seguenti modelli
4
Indice
Altri manuali Pondmaster Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente