PR PRetrans 5104 Manuale utente

SIGNALS THE BEST
5104
Repeater /
Power Supply
No. 5104V104-UK
From ser. no. 030250001

1245
PR electronics A/S tilbyder et bredt program af analoge og digitale
signalbehandlingsmoduler til industriel automation. Programmet
består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere,
Universaltransmittere m. Vi har modulerne, du kan stole på i selv
barske miljøer med elektrisk støj, vibrationer og temperaturud-
sving, og alle produkter opfylder de strengeste internationale stan-
darder. Vores motto »Signals the Best« er indbegrebet af denne
loso – og din garanti for kvalitet.
PR electronics A/S offers a wide range of analogue and digital
signal conditioning modules for industrial automation. The product
range includes Isolators, Displays, Ex Interfaces, Temperature
Transmitters, and Universal Modules. You can trust our products
in the most extreme environments with electrical noise, vibrations
and temperature uctuations, and all products comply with the
most exacting international standards. »Signals the Best« is the
epitome of our philosophy – and your guarantee for quality.
PR electronics A/S offre une large gamme de produits pour le
traitement des signaux analogiques et numériques dans tous
les domaines industriels. La gamme de produits s’étend des
transmetteurs de température aux afcheurs, des isolateurs aux
interfaces SI, jusqu’aux modules universels. Vous pouvez compter
sur nos produits même dans les conditions d’utilisation sévères,
p.ex. bruit électrique, vibrations et uctuations de température.
Tous nos produits sont conformes aux normes internationales les
plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne
de conduite - et pour vous l’assurance de la meilleure qualité.
PR electronics A/S verfügt über ein breites Produktprogramm
an analogen und digitalen Signalverarbeitungsmodule für die in-
dustrielle Automatisierung. Dieses Programm umfasst Displays,
Temperaturtransmitter, Ex- und galvanische Signaltrenner, und
Universalgeräte. Sie können unsere Geräte auch unter extremen
Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen
und Temperaturschwingungen vertrauen, und alle Produkte von
PR electronics werden in Übereinstimmung mit den strengsten
internationalen Normen produziert. »Signals the Best« ist Ihre
Garantie für Qualität!
DK
UK
FR
DE

5104V104-UK 1
REPEATER / POWER SUPPLY
PRetrans 5104
Table of contents
Warning .............................................................................. 2
Symbol identification.......................................................... 3
Safety instructions.............................................................. 3
EC declaration of conformity ............................................. 5
How to demount System 5000 .......................................... 6
Application ......................................................................... 7
Technical characteristics .................................................... 7
Mounting / installation........................................................ 7
Applications........................................................................ 8
Order: 5104 ........................................................................ 9
Electrical specifications...................................................... 9
DIP-switch programming ................................................... 12
Connections ....................................................................... 13
Block diagram .................................................................... 14
UL Control Drawing 5104QU01 ......................................... 15

2 5104V104-UK
WARNING
Until the device is fixed, do not connect hazardous voltages to
the device.
The following operations should only be carried out on a
disconnected device and under ESD safe conditions:
Dismantlement of the device for setting of DIP-switches
and jumpers.
General mounting, connection and disconnection of wires.
Troubleshooting the device.
Repair of the device and replacement of circuit breakers
must be done by PR electronics A/S only.
WARNING
SYSTEM 5000 must be mounted on DIN rail according to DIN
46277.
The communication connector of SYSTEM 5000 is connected
to the input terminals on which dangerous voltages can occur,
and it must only be connected to the programming unit Loop
Link by way of the enclosed cable.
GENERAL
INSTAL-
LATION
HAZARD-
OUS
VOLTAGE
WARNING
This device is designed for connection to hazardous electric
voltages.
Ignoring this warning can result in severe personal injury or
mechanical damage.
To avoid the risk of electric shock and fire, the safety instructions
of this manual must be observed and the guidelines followed.
The specifications must not be exceeded, and the device must
only be applied as described in the following.
Prior to the commissioning of the device, this manual must be
examined carefully.
Only qualified personnel (technicians) should install this device.
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.

5104V104-UK 3
SYMBOL IDENTIFICATION
Triangle with an exclamation mark: Warning / demand. Potentially
lethal situations.
The CE mark proves the compliance of the device with the essential
requirements of the directives.
The double insulation symbol shows that the device is protected by
double or reinforced insulation.
Ex devices have been approved acc. to the ATEX directive for use in
connection with installations in explosive areas.
SAFETY INSTRUCTIONS
DEFINITIONS
Hazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and
50 to 1000 Volt AC.
Technicians are qualified persons educated or trained to mount, operate, and
also troubleshoot technically correct and in accordance with safety regulations.
Operators, being familiar with the contents of this manual, adjust and operate
the knobs or potentiometers during normal operation.
RECEIPT AND UNPACKING
Unpack the module without damaging it. The packing should always follow the
module until this has been permanently mounted. Check at the receipt of the
module whether the type corresponds to the one ordered.
ENVIRONMENT
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock,
as well as rain and heavy moisture. If necessary, heating in excess of the stated
limits for ambient temperatures should be avoided by way of ventilation.
All devices fall under Installation Category II, Pollution Degree 1, and Insulation
Class II.

4 5104V104-UK
MOUNTING
Only technicians who are familiar with the technical terms, warnings, and
instructions in the manual and who are able to follow these should connect the
device.
Should there be any doubt as to the correct handling of the device, please
contact your local distributor or, alternatively,
PR electronics A/S,
www.prelectronics.com
Mounting and connection of the device should comply with national legislation
for mounting of electric materials, i.e. wire cross section, protective fuse, and
location. Descriptions of input / output and supply connections are shown in
the block diagram and side label.
The following apply to fixed hazardous voltages-connected devices:
The max. size of the protective fuse is 10 A and, together with a power
switch, it should be easily accessible and close to the device. The
power switch should be marked with a label telling it will switch off the
voltage to the device.
Year of manufacture can be taken from the first two digits in the serial number.
CALIBRATION AND ADJUSTMENT
During calibration and adjustment, the measuring and connection of external
voltages must be carried out according to the specifications of this manual. The
technician must use tools and instruments that are safe to use.
NORMAL OPERATION
Operators are only allowed to adjust and operate devices that are safely fixed
in panels, etc., thus avoiding the danger of personal injury and damage. This
means there is no electrical shock hazard, and the device is easily accessible.
CLEANING
When disconnected, the device may be cleaned with a cloth moistened with
distilled water.
LIABILITY
To the extent the instructions in this manual are not strictly observed, the
customer cannot advance a demand against PR electronics A/S that would
otherwise exist according to the concluded sales agreement.

5104V104-UK 5
EC DECLARATION OF CONFORMITY
As manufacturer
PR electronics A/S
Lerbakken 10
DK-8410 Rønde
hereby declares that the following product:
Type: 5104
Name: Repeater / Power Supply
is in conformity with the following directives and standards:
The EMC Directive 2004/108/EC and later amendments
EN 61326-1 : 2006
For specification of the acceptable EMC performance level, refer to the
electrical specifications for the device.
The Low Voltage Directive 2006/95/EC and later amendments
EN 61010-1 : 2001
The ATEX Directive 94/9/EC and later amendments
EN 50014 : 1997 E incl. A1+A2, EN 50020 : 2002 E
and EN 50281-1-1 : 1998 incl. A1
ATEX certificate: DEMKO 99ATEX126013
No changes are required to enable compliance with the replacement standards:
EN 60079-0 : 2009 and EN 60079-11 : 2012
Notified body:
UL International Demko A/S
Lyskaer 8, P.O. Box 514
2730 Herlev
Denmark
Rønde, 5 November 2012 Kim Rasmussen
Manufacturer’s signature

6 5104V104-UK
HOW TO DEMOUNT SYSTEM 5000
First, remember to demount the connectors with hazardous voltages.
Picture 1:
By lifting the bottom lock, the device
is detached from the DIN rail.
Picture 2:
Then, by lifting the upper lock and
pulling the front plate simultaneously
the PCB is removed.
Switches and jumpers can now be
adjusted.

5104V104-UK 7
REPEATER / POWER SUPPLY
PRetrans 5104
• 1- or 2-channel version
• 3- / 5-port 3.75 kVAC galvanic isolation
• Loop supply > 17.1 V
• 20 programmable measurement ranges
• Universal supply by AC or DC
Application
• Supplyvoltageandsafetybarrierfor2-wiretransmittersmountedina
hazardous area.
• Safetybarrierforanaloguecurrent/voltagesignalsfromhazardousarea.
• 1:1orsignalconversionofanaloguecurrent/voltagesignals.
Technical characteristics
• The20factory-calibratedmeasurementrangesinthe5104canbeselected
by the internal DIP-switches without the need for a recalibration. Special
measurement ranges can be delivered.
• PR5104isbasedonmicroprocessortechnologyforgainandoffset.The
analogue signal is transmitted at a response time of less than 25 ms.
• Inputs,outputs,andsupplyarefloatingandgalvanicallyseparated.
• Theoutputcanbeconnectedeitherasanactivecurrent/voltagetransmitter
or as a 2-wire transmitter.
Mounting / installation
• MountedverticallyorhorizontallyonaDINrail.Bywayofthe2-channel
version up to 84 channels per metre can be mounted.
• NB: 5104B is recommended as Ex barrier for 5331D, 5333D, 5334B, 5343B,
6331B, 6333B, and 6334B.

8 5104V104-UK
APPLICATIONS
3-wire transmitter
Current, mA
Voltage
2-wire transmitter
Output
Supply
Supply
Supply
Supply
Output
Output
Output
Altri manuali per PRetrans 5104
1
Indice
Altri manuali PR Ripetitore