CONTENTS
1. Safety Warnings
2. Definition, Dimensions and Technical Specifications of the Cooker Hood
3. Mounting of the Cooker Hood
3.1. Location of the Cooker Hood
3.2. Mounting of Hanger Screws on the Wall
3.3. Mounting of Connection Sheets of the Interior Chimney
3.4. Mounting of Cooker Hood on the Wall
3.5. Mounting of Plastic Chimney Adaptor and Air Escape Pipe
3.6. Mounting of Exterior Chimney
3.7. Mounting of Interior Chimney
4. Use of the Cooker Hood
4.1. Control Panel
4.1.1. Touch Control Panel
4.1.2. Touch Control Panel 3 Speed
4.2 Usage of the Cooker Hood
4.2.1. Use With Chimney
4.2.2. Use Without Chimney
4.3. Use of Aluminum Filter
5. Replacement of Lamps
5.1. Replacement of Led Lamp
6. Maintenance and Cleaning
7. Recommendations
8. Things to be Done If the Cooker Hood is not Working
9. Guarantee
9.1. Terms of Guarantee
9.2. Situations Outside the Scope of Guarantee
1.SAFETY WARNINGS
Please read this manual throughly of and follow the instructions!
This manual is a part of your device and has to be kept for future use.
As this manual applies to more than one model, it may include some equipment and features that are not
available in your device.
This device is produced as household type for personal use. It should not be used for commercial purposes
or for the wrong purposes.
The width of your device has to be at least as wide as the width of your cooker.
Once you have unpacked your device, make visual check to see whether there is any damage. If there is
damage caused by shipping, do not mount the device.
Keep packing materials away from children as they may be dangerous (drowning, swallowing, etc.).
Mounting process and electrical connection should be performed by authorized persons. In the mounting
process, attention should be paid to current applicable building regulations, regulations of local electricity and
gas enterprises and regulations on air discharge systems.
The producing company will not accept responsibility for accidents, damages, fires and/or injuries that may
occur due to the mounting and/or usage of the product in a manner not in accordance with the instructions
specified in the manual.
There is a risk of injury during mounting due to sharp edges that may be in your device. Therefore, protective
gloves should be worn during the mounting of your device.

Mounting of your device should be performed with mounting accessories inside the product package. All
fittings available in the mounting accessories should be used in order to complete the safe mounting of your
device. Unlike, materials such as adhesives, screws, nails etc. should not be used.
When mounting your device, the mounting template inside the mounting accessories should be used. The
minimum height of your device from the cooker surface should be 75cm in gas cookers and 65cm in electric
cookers. If gas cookers and electric cookers are used together, the minimum distance should be 75cm.
The device should be mounted on the wall on a flat surface.
Air escape pipe should not be connected to the chimneys containing waste gas such as gas heater,
thermosiphon, combi boiler, heating stove and fireplace and a minimum Ø120mm air escape pipe should be
used. Also, if it is not a specially designed opening, the outlet air should not be given to the wall opening.
This warning does not apply to devices used without a chimney (carbon filter).
The air escape pipe should be as short as possible and have few elbows. This warning does not apply to
devices used without a chimney (carbon filter).
If adequate ventilation is not provided when your device is in operating state, vacuum will be generated as
your device will draw the ambient air. In this case, the gases of other products used as chimney and
containing waste gas (gas heater, thermosiphon, combi boiler, heating stove, fireplace, etc.) may enter the
ambient again and cause poisonings. The negative pressure in the room should be at most 4 Pa (0.04
mbar). This warning does not apply to devices used without a chimney (carbon filter).
The flaps at the outlet of the chimney on your device should be in the open position when the motor is
running and in the off position when the motor is not running. The negativities that prevent this situation
should be removed. This warning does not apply to devices used without a chimney (carbon filter).
The electrical connection should not be made before the mounting of your device is completed.
If the power supply cable is damaged, the mounting of the device should not be performed and a new one
should be supplied from the authorized service and be replaced.
The operating voltage of your device is 220-240V and should be connected to a grounded power network.
If there is a supply cord and plug in your device, the device should be mounted so that the plug can be easily
reached.
If your device is to be connected directly to the electric network, it is necessary to place a switch between the
device and the network, of which minimum clearance between the contacts is 3 mm and dimensions are in
accordance with the load and the law in force.
During the mounting, the supply cable should not be exposed to heat, jamming or crushing.
For your safety, the "MAX 6A" fuse should be used in the device connection wiring.
After the mounting of your device is completed, the white and/or transparent protective foil on the inox
(stainless) surfaces should be removed without damaging the product.
The device should not be operated without a filter. The filters should not be removed from their places when
the device is in the operating state.
The filters in your device sould be replaced and/or washed in the specified periods. Filters that are not
replaced and/or washed on time are have the risk of fire due to oil deposits on them. In addition, these oil
deposits will reduce the performance of your device.
Before cleaning or maintaining, it should be waited for the cooling of the device. The fuse should be switched
off or the electric outlet should be unpluged.
When cleaning the interior of the cooker hood, it should be very careful and gloves should be worn.
Non-flame-resistant filtering materials should not be used instead of filter. The original filters of the producer
company should be used.

The cooking tool (pot, pan, etc.) should be placed on the cooker before flaming the gas burner in your
cooker, and the gas burner should be flamed after bringing your cooker hood to operating state.
The flame in your cooker should be adjusted so that it will not overflow from the cooking tool (pot, pan, etc.).
The cooker should be turned off before the cooking tool (pot, pan, etc.) over the cooker is taken.
The cooker hood should be operated for 15 minutes more to ventilate the environment, to remove the food
smells, and to dry the humidity in the carbon filter present in the cooker hoods used without a chimney.
The use of naked flame in your cooker under your device poses s filters and other
components, which can cause a fire. For this reason, flaming cookings should be avoided and it should be
exposed to high naked flames.
Do not ever run the two gas burners on your cooker at the same time longer than 15 minutes in the largest
flame setting. A big burner with power more than 5kW (vok) equals the power of two gas burners.
When cooking foods such as frying, these types of cookings should be constantly monitored, as the oils may
burst into flames.
In case of any possible flamimg, the gas burner of the cooker should be extinguished, the electrical
connections of the cooker hood and the cooker should be disconnected. Fire should always be extinguished
using a damp cloth, fire-fighting blanket, suitable cover or dish, but never with water.
Persons who have mental, physical, or sensory restrains, who do not have experienceand knowledge in
using the device, and the children should not use this device.
Ensure that your child does not play with this product.
Broken bulbs should be replaced immediately to avoid overloading in other bulbs. The bulbs of your device
will heat up when they work for a long time. In this case, the bulbs should not be touched.
The bulbs in your device are designed for cooker lighting. It should not be used as ambient lighting.
Otherwise, the life of your bulbs will shorten.
In case of failure, the nearest authorized service should be called.
Never place any objects on the device.
In order to ensure that your device is long-lasting and not corroded, the cooker hood should also be operated
while the cooker is in use.
LED lamps should not be viewed for more than 3 seconds.

2. DEFINITION, DIMENSIONS AND TECHNICAL SPECIFICATIONS OF THE COOKER HOOD
JOYS

ALESSA
ENZO

OLIVERA
REMO

3.MOUNTING OF THE COOKER HOOD
3.1. LOCATION OF THE COOKER HOOD
The mounting height of JOYS-OLIVERA models devices should be minimum 52cm, maximum 62cm from the
surface of the cooker in gas cookers, and 42cm minimum, 52cm maximum from the surface of the cooker in
electric cookers (illustration 1). The mounting height of ALESSA-ENZO models device should be minimum
57cm, maximum 67cm from the surface of the cooker in gas cookers, and minimum 47cm, maximum 57cm
from the surface of the cooker in electric cookers (illustration2). The mounting height of REMO model device
should be minimum 65cm, maximum 75cm from the surface of the cooker in gas cookers, and minimum
55cm, maximum 65cm from the surface of the cooker in electric cookers (illustration3).
Illustration 1

Illustration 2
Illustration 3
3.2. MOUNTING OF HANGER SCREWS ON THE WALL
Attach the mounting template, which comes out of the mounting accessories, to the surface where the
cooker hood will be hanged, according to the appropriate height that should be from the surface of the
cooker. For JOYS-OLIVERA (Illustration 4.a), ALESSA (Illustration 4.b), ENZO (Illustration 4.c) and REMO
(Illustration 4.d) models drill with an auger of Ø8mm from the places indicated by A, B, C, D marks. Bang the
dowels of 8mm, which came out of mounting accessories, to these holes with the help of a hammer, without
damaging the dowels, and tighten these dowels with 2 hanger screws of 4x40 YHB, which again came out of
mounting accessories, in a way that the head of the screw will be left out about 6-8mm (Illustration 6).

Illustration 4.a
Illustration 4.b
Questo manuale è adatto per i seguenti modelli
4
Indice
Lingue:
Altri manuali Premium Cappa di ventilazione