ECCO advanced settings
Starting from EAGLE Manager 2.0 version, in the Advanced Settings you can find:
- Delta-T: the temperature that ECCO adds to the dew point temperature relative the numbered dew hea-
ter. The larger your optic, the higher we suggest to set this value in order to keep your optic uniformly
heated.
Troubleshooting
Q: When I click on ECCO button in the EAGLE Manager, it doesn’t connect.
A: If you see the “No ECCO found” after you press ECCO button, it means that Windows didn’t properly load the
driver when you connected ECCO’s USB cable to your EAGLE. With the ECCO disconnected from the USB port,
please go to Control Panel, then select Device Manager. Here you see the list of all the devices. Please connect
ECCO’s USB cable and you will see the list updating. If the new found device has a yellow mark, it means that the
driver has not automatically loaded. Make a mouse right-click on it and select “Update Driver”. In the new window
select “Browse my computer for driver software”, click on Browse button and select the folder where you previously
unzipped the “ECCO software package” zip file, that includes also the system driver. This will manually install the
ECCO driver, reboot your EAGLE and connect again to the ECCO in the EAGLE Manager.
Q: My telescope has dew on optics also if I use the ECCO.
A: First of all please check that, when ECCO applies power to dew heaters, they warm up. If the dew heaters are
fine, we suggest you to increase (for example to 2-3 degrees) the Delta-T value in the EAGLE Manager ADVAN-
CED SETTINGS.!