Pro Breeze PB-AC01 Manuale utente

instruction manual
mode d'emploi
bedienungsanleitung
manuale di istruzioni
manual de instrucciones
9000 BTU portable air conditioner
MODEL PB�AC01

Portable Air Conditioner
Safety Warning
•
•
•
•
•
•
•
Thank you for choosing to purchase a product from Pro Breeze. Please read the entire
manual carefully prior to first use and keep in a safe place for future reference.
01 | English
Use the appliance only as described in this
instruction manual.
Check that the voltage of the main circuit
corresponds with the rating of the appliance
before operating.
This appliance is suitable for indoor use only.
This appliance is not a toy. Never leave
unattended around children or pets.
Ensure the power cord plug is properly
inserted into the power socket before
operating.
Where there is the need to install a continu-
ous drainage hose ensure the connection of
the drainage hose is in good condition
without flexure.
Do not cover the power cord.
Contents
Safety Warning
Specific Information Regarding R290 Refrigerant Gas
Caution ┃Specification
Parts
Control Panel
Installation
Controls
Emptying the Water Tank
Connecting the Water Hose for Continuous Draining ┃Cleaning
Storage
Safety Features ┃ Helpful Information
Disposal
01
03
04
05
06
07
10
12
13
14
15
16
Pg

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
This appliance can be used by children
aged from eight years above and persons
with reduced physical, sensory or mental
capabilities or lack of experience and
knowledge if they have been given
supervision or instruction concerning use of
the appliance in a safe way and understand
the hazards involved.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be
made by children without supervision.
Keep the appliance and all parts out of the
reach of children.
This appliance is intended for domestic use
only. It should not be used for commercial
purposes.
Place the appliance on a flat and dry
surface. Keep it at least 50cm away from
surrounding walls and/or objects.
When moving the appliance ensure it is
kept in an upright position.
When adjusting the louvres do so gently so
as not to cause damage.
Do not insert fingers or objects into the air
inlet or air outlet. Be sure to keep the air
inlet and air outlet unblocked.
Do not operate the appliance with wet
hands.
Do not leave the appliance unattended
whilst connected to the power supply.
Do not pull the power cord to stop the
appliance.
Do not unplug the appliance until it has
been switched off.
Do not modify the appliance or use any
accessories other than those supplied.
Do not place or use the appliance, power
cord, or any accessories in a bathroom,
wet, or damp place.
Do not cover the appliance whilst in use.
Do not use pressurised containers (e.g.
aerosol cans) or other flammable substances
near the appliance.
Do not use the appliance near petrol,
flammable gases, ovens, or other heating
sources.
Do not allow water or other liquids to enter
into the appliance or contaminate electrical
parts.
Do not attempt to repair or adjust any
electrical or mechanical elements in the
appliance. Doing so may be unsafe and will
void your warranty.
Do not operate the appliance if there are
signs of damage to the appliance, power
cord, or any of the accessories.
Do not wipe or wash the appliance with
chemical solvents. Prior to cleaning ensure
the appliance is turned off and unplugged
from the power supply.
Avoid placing the power cord in areas where
it can become a tripping hazard.
Avoid using extension cables as they may
overheat and cause a fire risk.
Unplug the appliance and store in a cool and
dry place when not in use.
Never place anything on top of the appliance.
English | 02

•
•
•
•
•
•
•
•
•
•
The appliance must be installed, used and
stored in an area that is greater than 13m².
This appliance contains 270g of R290
refrigerant gas.
R290 is a refrigerant gas that complies with
the European directive on the environment.
Do not puncture any part of refrigerant
circuit.
Be aware R290 refrigerant is odourless and
does not have the odour normally associated
with natural gas and propane tanks.
The appliance must be placed in an area
without any continuous sources of ignition
such as open flames, gas, or electrical
appliances in operation.
Do not puncture and do not burn.
If the appliance is installed, operated or
stored in a non-ventilated area, the room
must be designed to prevent the accumula-
tion of refrigerant leaks resulting in a risk of
fire or explosion due to ignition of the
refrigerant caused by electric heaters,
stoves, or other sources of ignition.
The appliance must be stored in such a way
as to prevent mechanical failure.
Individuals who operate or work on the
refrigerant circuit must have the appropriate
certification issued by an accredited
organisation that ensures competence in
handling refrigerants according to a specific
evaluation recognised by associations in the
industry.
•
Maintenance and repairs that require the
assistance of other qualified personnel must
be performed under the supervision of an
individual specified in the use of flammable
refrigerants.
Specific Information
Regarding R290
Refrigerant Gas
03 | English
CAUTION
RISK OF FIRE

Caution
Specification
•Do not operate the appliance if the room
temperature is greater than 32°C in
cooling mode or lower than 5°C in
dehumidifying mode.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Input Voltage: 220V-240V~
Frequency: 50Hz
Cooling Capacity: 9000 BTU/H
Refrigerant: R290
Energy Efficiency Class: A
Rated Capacity For Cooling: 2640W
Rated Input | Cooling: 1010W
Rated Current | Cooling: 4.4A
Noise Level | 65dB
EER For Cooling: 8.9 BTU/H
EER For Cooling: 2.6 W/W
Moisture Removal: 0.9L/H
Air Flow Volume: 360m³/H
Applicable Area: 18-22m²
Operating Temperature Range: 5-32°C
Available Temperature Settings: 16-30°C
Global Warming Potential: 3kg CO2 eq.
Net Weight: 24.5kg
Size: 30cm x 35.2cm x 75.6cm
English | 04

Front View
Control panel
Horizontal louvre
Vertical louvre
Body
Wheels
1.
2.
3.
4.
5.
4
5
3
2
1
Rear View
Handle/remote control storage
Body
C-shaped buckle
Power cord
Heat exhaust hose connector
Power cord tidy
Wheels
Evaporator filter
Radiating filter
Condenser filter
Drain cap.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
Accessories
Remote control
Heat exhaust hose short connector
Heat exhaust hose
Sliding window sealing board assembly
Circular connector
Hinged window fabric sealing assembly
Sealing velcro
Water hose
7
12
9
10
14
13
15
16
11
8
6
Parts
05 | English
17 18
21
20 19
22
23
24

Buttons moving from right to left
Power button
Fan speed Button
Down Button
Up button
Mode Button
Timer button
•
•
•
•
•
•
Remote Control
Digital display panel moving from
right to left
Degrees fahrenheit indicator light
Degrees celsius indicator light
•
•
Indicator light symbols moving
from right to left
Low fan speed indicator light
High fan speed indicator light
Water tank full indicator light
Sleep mode indicator light
Fan-only mode indicator light
Dehumidifying mode indicator light
Cooling mode indicator light
Timer mode indicator light
•
•
•
•
•
•
•
•
1.
2.
3.
TIMER COOL DRY FANSLEEP FULL HIGH LOW
TEMP
Cool
Dry
Fan
High
Low
Sleep
Timer Power
ºC/ºF
High fan
speed button
Cool mode
button
Dehumidifying
mode button
Fan-only mode
Low fan
speed button
Sleep mode
button
Timer
Power
Temperature
digits change
button
Control Panel
English | 06
22
3
11
Note: Two AAA batteries included.

07 | English
Prior to and after installation adhere to
the below:
•
•
•
•
When moving the appliance to the chosen
location ensure it is kept in an upright position.
Do not place or use the appliance, power cord,
or any accessories in a bathroom, wet, or damp
place.
Place the appliance on a flat and dry surface.
Keep it at least 50cm away from surrounding
walls and/or objects.
Leave the appliance in an upright position for
at least two hours before first use.
Exhaust Hose Short Connector Installation
Align the two halves and click firmly together.
Stand the heat exhaust hose upright with the
circular connector at the bottom.
Place the exhaust hose short connector on top
of the heat exhaust hose and push down firmly
so that the neck sits over the heat exhaust hose.
Holding the heat exhaust hose firmly at the
bottom rotate the exhaust hose short connector
counterclockwise locking the three screw
threads onto the heat exhaust hose.
C-Shaped Buckle Installation
Align the c-shaped buckles rotary hole with
the rotation shaft and slide fully onto the
rotation shaft.
Rotate the c-shaped buckle counterclockwise
until it locks over the snap joint.
1.
2.
Rotary hole
Rotation shaft
Snap joint
Side view A
Side view B
1
2
1.
2.
3.
4.
2
3
1
Installation

Notes:
•
•
If your window opening is smaller than the
minimum length of the sealing board assembly
trim to desired length using a hack saw.
If your window opening is larger than the
maximum length of the sealing board assembly
use plywood or similar to fill the gap.
Sliding Windows Sealing Board
Assembly Installation
Insert panel B into panel A and adjust to
the length or height of the window.
Open window and place the sealing board
assembly into window.
Adjust to ensure an exact fit and secure
with the provided screw.
Close window to lock everything into
place.
Attach the heat exhaust hose short
connector to the elliptical hole.
The sealing board assembly is now ready
for use.
1.
2.
3.
4.
5.
6.
Unlock and fully open the c-shaped
buckle.
Place the lip of the circular connector over
the bottom step of the heat exhaust hose
connector.
Firmly push the circular connector down
into the heat exhaust hose connector to
lock it into place.
Return the c-shaped buckle to secure.
1.
2.
3.
4.
1
4
Bottom step
Circular connector
2
3
1
3
3
2
5
5
4
2
4
Panel A
Panel B
Horizontal Window
Vertical Window
English | 04
Heat Exhaust Hose Installation
English | 08

Open window and clean frame and
casement surfaces of dust and particles.
Stick the velcro tape around the entire
window frame. Never stick to the window
seal as doing so will prohibit the window
from closing fully.
Stick the velcro tape around the entire
window casement (inside or outside).
Check to ensure the window can close
fully.
Attach side A of the sealing fabric
assembly to the velcro on the window
frame working from the centre outwards.
Close and open window to ensure no
fabric gets trapped.
Attach side B of the sealing fabric
assembly to the velcro on the window
casement working from the centre
outwards.
Open the window slightly and insert the
heat exhaust hose short connector into
the sealing fabric assembly securing with
the zippers around its lip.
The sealing fabric assembly is now ready
for use.
Notes:
•
•
Do not bend the heat exhaust hose in
excess of 45 degrees. It should be as short
and as straight as possible to ensure
efficient air flow.
Do not overstretch the heat exhaust hose as
this may affect the appliances efficiency
Hinged Window Sealing Fabric
Assembly Installation
1.
2.
3.
4.
5.
6.
7.
8.
Frame
Side A
Side B
Casement
7
4 & 6
2 & 3
Hinged window sealing fabric zip
09 | English
Altri manuali per PB-AC01
1
Indice
Lingue:
Altri manuali Pro Breeze Condizionatore d'aria

Pro Breeze
Pro Breeze PB-AC03 Manuale utente

Pro Breeze
Pro Breeze PB-AC02 Manuale utente

Pro Breeze
Pro Breeze PB-AC05 Manuale utente

Pro Breeze
Pro Breeze PB AC04 Manuale utente

Pro Breeze
Pro Breeze PB-AC03 Manuale utente

Pro Breeze
Pro Breeze PB-AC04 Manuale utente

Pro Breeze
Pro Breeze PB-AC06 Manuale utente

Pro Breeze
Pro Breeze PB-AC03 Manuale utente

Pro Breeze
Pro Breeze PB-AC05 Manuale utente

Pro Breeze
Pro Breeze PB-AC05 Manuale utente























