Pro-Built Tools PB-Mycro Manuale utente

PB Mycro
PB2000
PB2400ES
PB3600ES
100’
130’
150’
200’
250’
Pro-Built Tools
User’s Guide
275’
300’
400’
500’
___

3

www.probuilttools.com
Diagram & Equipment Specifications...........4
Equipment Specs & Safety Instructions.......5
Control Panel................................................6
Initial Setup Guide........................................7
Locating.....................................................8-9
Digital On-Screen Footage Counter...........10
SD Recorder..........................................11-13
Tips in the Field.....................................14-15
“No Video/Signal” Guide...............................16-17
Trouble Shooting...................................18-20
Head Removal & Installation........................21-23
Warranty & Contact Information.........................24
TABLE OF CONTENTS
3

www.probuilttools.com
DIAGRAM & SPECIFICATIONS
4
A. Camera Head
B. Patch Cord Input (Reel Side)
C. Cable Guide
D. Powder Coated Frame
E. Heat Treated Epoxy Sealed SV Cable
F. Rubber Feet
Included Not Pictured
- Control Box - See Page 7 Diagram
- CAT-6 Patch Cord.
a
b
c
d
e
f

www.probuilttools.com
EQUIPMENT SPECIFICATIONS
SAFETY INSTRUCTIONS
5
• Pro-Built Standard Fixed Head
Dimension: 1.29” Diameter
Pipe Size: 2“ Pipe + (2” Pipe Depends on Condition of Pipe)
• Pro-Built Self Leveling Head
Dimension: 1.95” Diameter
Pipe Size: 3“ Pipe + (3” Pipe Depends on Condition of Pipe)
• High Tension Pro-Built Inspection Cable Push Capacity:
100’ – 500’ (depending on condition of line)
• Steel Reel
16” -36” in Diameter Depending on Model Purchased
• Camera Material
Air Craft Aluminum
• Depth Rated
Submersible to 500’
1.) Keep all buttons, handles, switches clean of oils & grease.
Please avoid setting control box directly in water.
2.) Prior to use inspect all buttons, handles, switches to make
sure they are in working order. If equipment is malfunctioning
please do not operate. See trouble shooting guidelines in back
of manual.

www.probuilttools.com
CONTROL PANEL
6
Main Controls:
Power – On/Off Switch
Dimmer Control – Dim LED Lights as Needed
Connection to Reel – Input Cat 6 Patch Cord
Video Output – Input any monitoring device
Sonde – Turn on to activate 512 Hz Sonde
Power Cord – Plug into 110-240 Volt grounded outlet
Inductive Locator Connection – Used to energize high
tension inspection cable – see locator manual if
applicable.
Digital Footage Counter Controls (optional depending on
model purchased)
.

www.probuilttools.com 7
INITIAL SETUP GUIDE
Models: PB2000, PB-Mycro, PB2400ES, PB3600ES
Upon inial receipt of your equipment, first check that your shipment has arrived intact. Please note any
physical damages to the shipping box and/or equipment. Any such damages should be reported
immediately so that a shipping claim can be made.
Package contents (not including any upgrades) are as follows:
1) Sewer Camera Reelwith Camera Head Installed (Sonde is located in the spring behind the head)
2) Control Box
a) Main Controller
b) Power Supply/Cord
c) 7” Color LCD with Remote
d) 6’ Reel to Controller Patch Cable
Equipment check & basic startup instrucons:
1) Plug the 6’ Reelto Controller Patch cable from the reel to the controller (both sides idencal)
a) Line up the notch in the cable housing end to the push-tab on the RJ45 Receptacle
b) Push the connectors in on each end to lock
2) Plug Power Supply/Cord into 110v-240v AC wall receptacle
3) Check that aYellow RCA plug is routed to the “video out” jack on the top of your controller
4) Make sure that your “sonde” switch is in the “off” posion
5) Power on the system by turning the “power” switch to the “on” posion
a) If the LCD doesnot turn on automacally, press the power buon on the LCD
b) If the LCD begins with a Blue Screen, Change the LCD input (V1/V2) in the LCD Menu

www.probuilttools.com 8
LOCATING YOUR CAMERA
Models: PB2000, PB-Mycro, PB2400ES, PB3600ES
Aer you’ve pushed your camera through the pipe and have decided that you are at a point where you
would like to determine the locaon and depth of your camera head, please follow these steps:
1) Turn on your “Sonde” by pressing the “Sonde” switch to the “on” posion. (The “Sonde” toggle
switch is located just above the “Power” toggle switch on the controller)
a) Note: This will make you either lose video (blue screen) or get horizontal lines over your
video – This is normal and means that your sonde is funconing.
b) Note: If you have a Digital On-Screen Footage Counter installed on you system, you will
instead see a black screen with only the footage showing – This is normal and means that
your sonde is funconing.

www.probuilttools.com 9
2) Aer your sonde is acvated, it is me to use your locator. This page specifically shows how to
use your PB550SL Digital Locator Wand in conjuncon with your PB Series sewer camera.
a) Turn on your locator by depressing the yellow buon in the handle grip.
i) NOTE: The locator will only remain on while this buon is depressed.
ii) Leng go of the handle will automacally power off the locator.
b) You may change the acve frequency by pressing the “F” buon on the face of the locator.
i) NOTE: Each press will toggle the acve frequency to the next on the list.
ii) 512Hz is the acve frequency for your PB Series sewer camera system.
c) Facing the SAME DIRECTION as the pipe, begin to walk towards your camera as shown:
d) The most important number to look at on the locator is the “peak” number on the lower-
right of the screen. Once that number is at its highest possible point AT THAT JOB, then you
are directly above the sonde and in-line with it.
e) When directly above the sonde, press and HOLD DOWN the red “i” buon on the face of the
locator. Aer approximately 2 seconds, it will beep and show you your depth measurement.
LOCATING YOUR CAMERA
Models: PB2000, PB-Mycro, PB2400ES, PB3600ES

www.probuilttools.com 10
DIGITAL ON-SCREEN FOOTAGE COUNTER
Models: PB2000, PB-Mycro, PB2400ES, PB3600ES
Your installed Digital On-Screen Footage Counter will display on the screen as follows:
The control panel for the Digital On-Screen Footage Counter is on the le half of your main controller:
The controls are as follows:
1) Reset – Will reset the on-screen footage count to 000.0
2) Hide Name – Will toggle the display of the name/phone number at the boom-center of the
screen on/off(if pre-programmed)
3) Hide Display – Will toggle the enre text overlay (date, me, count, name) on/offthe screen
4) Set/Move – Use to set the date/me
5) Increment – Use to set the date/me
How to set the date/me:
1) Hold down the “Set/Move” buon for approximately 7 seconds unl “Set Month” appears on
the screen
2) Press the “Increment” buon to raise the value of the high-lighted field +1
3) Press the “Set/Move” buon to move to the next field, in this order: Month, Date, Years, Hours,
Minutes, Seconds, Hour Mode
a) Hour Mode – Allows for 12 hour clock (AM/PM) or 24 hour clock
b) Seconds – Pressing the “Increment” buon while on “Seconds” will reset to zero seconds
c) Pressing the “Set/Move” buon aer the “Hour Mode” field will remove you from
programming mode.
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali Pro-Built Tools Macchina fotografica digitale