Pro-tec AC-200 Manuale utente

PROTEC AC-200 USER MANUAL
AC-200
USER MANUAL

PROTEC AC-200 USER MANUAL
Congratulation on the purchase of the AC-200
Refrigerant Processor
This is a very good investment you have made for your workshop. This system will help your technicians in achieving their
best capability in diagnosing and rectifying air-conditioning issues, thus increasing productivity and profitability for your
business. This system can be customized to suit each individual workshop needs. Our company would like to work with you
as partners in your business to help you achieve maximum return on your investment, so please do not hesitate to contact us
or our distributors, if we can be of any further assistance in relation to this equipment use and maintenance, or any
air-conditioning related issues. We are always here to help you in achieving higher productivity.
AC-200 is an ideal option for workshops that have limited equipment investment budget. Even economic, the machine is
robustly built, with luxurious features such as color LCD display, amply database and patented oil separator/manifold. The
unique design has facilitated quick load cell unlock, easy and economic maintenance (DIY maintenance recommended), self
troubleshooting and convenient USB upgrade etc..
General safety
The storage cylinder in this unit contains liquid refrigerant. Overfilling of the cylinder can cause violent explosion. Do
not disable the overfill safety feature. Always keep the cylinder on the load cell platform whenever operating the
machine.
The operator must carefully read the instruction manual before any operation is performed. Incorrect operations could
cause serious consequences, such as, improper A/C service, damage to automotive A/C system or damage to
equipment.
Only use cylinders which are recommended by the manufacturer and supplied with this equipment.
Avoid inhalation of refrigerant or oil vapor/mist, read material safety instructions on refrigerant and oil package.
Switch off and disconnect power cable from main supply before removing any cover or servicing the equipment, to
avoid electric shock which can be very dangerous or fatal.
Never use compressed air for leak testing the unit or vehicle A/C system!
Wear safety goggles and gloves, to protect eyes and skin from contact with refrigerant. Coming in contact with liquid
refrigerant can cause frostbite and blindness. If accidental contact is made with liquid refrigerant, wash effected area
with plenty of fresh water and contact a doctor.
Avoid using extension power cable than 1.5mm2copper core.
Keep gasoline or other flammable substances away from the equipment.
Always operate unit in a well-ventilated area and away from artificial heat

TEKTINO AC-200 USER MANUAL
V3.00
1/13
INDEX
SPECIFICATIONS----------------------------------------------------------------------------------------------------------------2
FUNCTION TABLE--------------------------------------------------------------------------------------------------------------3
PART DESCRIPTION------------------------------------------------------------------------------------------------------------4
OPERATION PREPARATIONS-------------------------------------------------------------------------------------------------5
EQUIPMENT CONNECTION(Recovery/vacuum/oil injection/charge/auto mode)-------------------------------------6
RECOVERY------------------------------------------------------------------------------------------------------------------------7
VACUUM---------------------------------------------------------------------------------------------------------------------------7
OIL INJECTION-------------------------------------------------------------------------------------------------------------------7
CHARGE---------------------------------------------------------------------------------------------------------------------------8
AUTO. MODE---------------------------------------------------------------------------------------------------------------------9
SYSTEM SETTING---------------------------------------------------------------------------------------------------------------9
UPDATE---------------------------------------------------------------------------------------------------------------------------10
SERVICE REMINDING--------------------------------------------------------------------------------------------------------11
MAIN TROUBLESHOOTING------------------------------------------------------------------------------------------------12

TEKTINO AC-200 USER MANUAL
V3.00
2/13
Specifications:
Dimension:Package 710*660*1190mm; Unpacked machine 610*595*1075mm3
Input power:AC220V±10%~50/60Hz,or AC110V±10%~60Hz
Compressor power:3/8HP
Average gas state refrigerant recovery speed (through charge/suction port):0.25Kg/min.
Hand valves free.
Recovery rate: 96%.
Vacuum pump capacity:60L/min, non-sparkle.
Accuracy of gas cylinder load cell:±10g
New oil bottle capacity:250ml
Used oil bottle capacity: 400ml
Max. Pressure:20bar
Charge speed:2Kg/Min(max.)
LCD display:4.3-inch,TFT full color
High pressure gauge range:-1bar~40bar
Low pressure gauge range:-1bar~22bar
A/C database included, update through USB port.
Automatic service reminding. The equipment provides 600 operations totally (each recovery or vacuum
counts for one operation, and automatic mode counts for 2 operations) between regular maintenance, When
600 operations have been made the machine automatically reminds to call distributor for service.

TEKTINO AC-200 USER MANUAL
V3.00
3/13
Function Table
Main function
Recovery
Recovers and purifies refrigerant from automotive A/C
to equipment tank.
Vacuum
Evacuates air and moisture from the A/C system.
Oil injection
Inject refrigeration oil to automotive A/C system.
Can inject oil by setting volume manually, or
automatically.
Charge
Charge refrigerant from equipment gas cylinder to
automotive A/C system
Auto. mode
Performs the selected functions in a fully automatic
sequence. The machine will stop automatically once all
the selected functions have been completed
Sys. setting
Language
Select operation language.
Calibration
Calibration refrigerant gas cylinder load cells.
Database
Enter automotive A/C database
Unit set
Select metric or imperial units
Empty container weight set
Set empty refrigerant gas cylinder.
Component test
Test work status of solenoids, vacuum pump and
compressor.

TEKTINO AC-200 USER MANUAL
V3.00
4/13
Part description
1)Refrigerant gas cylinder
2)Refrigerant gas cylinder support
plate
3) Refrigerant gas cylinder load cell
4)Drier-filter
5)Manifold assembly
6)Assembly of solenoid valve and
check valve
7)Base
8)Condenser and cooling fan
9)Compressor
10) Back cover1
11)Front wheel
12)Rear wheel
13)Shell
14)Vacuum pump
15)Capacitor
16)Low pressure gauge
17)Fuse
18)Power supply
20)High pressure gauge
21) Panel
22)Back cover2

TEKTINO AC-200 USER MANUAL
V3.00
5/13
OPERATION PREPARATIONS
Unlock load cells.
Remove the bolt that fix tank platform with chassis, to release tank load cell.
Fill equipment with refrigerant (New equipment is empty, you need to fill the equipment
with refrigerant and refrigeration oil)
Connect either HP or LP hose with external refrigerant R134a or HFO-1234yf tank, and turn on
the machine, select corresponding refrigerant type, run recovery to fill equipment with refrigerant.
After one refrigerant tank is filled, fill other tank with its corresponding refrigerant.
It is recommended to maintain both tanks at 3-6kg refrigerant.
Air purge
It is recommended to purge the air in equipment tanks every day before turn on the machine. At
left and right sides of machine, air purge manual valves and P-T chart can be found. Turn the
valve to purge the air, strictly abiding by the pressure to be consulted in chart, corresponding to
environmental temperature.

TEKTINO AC-200 USER MANUAL
V3.00
6/13
Equipment Connection (For recovery/vacuum/oil injection/charge/Auto. Mode)
Warning: Except the situations clearly stated in the manual, during recovery and all other equipment
operations, please maintain the vehicle engine and A/C off, otherwise unexpected damages may be caused.

TEKTINO AC-200 USER MANUAL
V3.00
7/13
Recovery
Empty used oil vessel before the recovery function is started.
Select “Recovery” function icon and press ENTER to start the process.
The recovery process recovers the refrigerant from vehicle A/C system, until a vacuum is achieved
in the vehicle A/C system. Moisture, oil and foreign particles are separated from the refrigerant
before it is stored in the internal refrigerant cylinder.
Vacuum
Select “Vacuum” icon and press ENTER to start the process.
The Vacuum process evacuates system, and makes system ready for oil injection and refrigerant
charge. Although it is up to users to determine vacuum time, a longer vacuum process is
recommended.
Oil injection
Select “Oil inj.” icon and press ENTER to start the process.
Oil enters A/C system through high side service hose.

TEKTINO AC-200 USER MANUAL
V3.00
8/13
You can choose “hose flush” to flush and discharge oil remaining in machine internal pipelines and
service hoses, to avoid cross contamination of different oils which may cause damage to A/C
system. It is a MUST to select “hose flush” when you inject POE or any other oil to hybrid or
electric vehicles, with PAG oil may remain in machine or service hoses because of previous
operations.
You can determine oil injection volume by setting amount or by manual injection. Manual oil
injection is effected by pressing right arrow key on control panel. Please be aware that there is no
oil load cell equipped in the machine (the oil injection volume is calculated by injection time), thus
the oil volume injected may vary from the amount preset.
Charge
Select “charge” icon and press ENTER to start the process.
You can manually set charge amount with volume, or select “Charge by database” to set charge
amount by car make and model.
You can choose to charge through high side, low side or both sides.
After charge and A/C performance is checked with engine and A/C ON. “Hose purge” option helps
charge the refrigerant in service hoses into vehicle A/C system, to ensure better charge precision.
Indice
Altri manuali Pro-tec Hardware per computer
Manuali Hardware per computer popolari di altre marche

EMC2
EMC2 VNX Series Manuale del proprietario

Panasonic
Panasonic DV0PM20105 Manuale utente

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Manuale utente

Gigabyte
Gigabyte B660M DS3H AX DDR4 Manuale utente

Raidon
Raidon iT2300 Manuale utente

National Instruments
National Instruments PXI-8186 Manuale utente