Project Source F201E514CP Manuale utente

1
Serial Number Purchase Date
ATTACH YOUR RECEIPT HERE
PROJECT SOURCE and logo design are
trademarks or registered trademarks of LF, LLC.
All rights reserved.
Questions, problems, missing parts? Before returning to your retailer, call our
customer service department at 1-866-389-8827, 8 a.m. - 8 p.m., EST, Monday - Sunday.
ITEM #1451697
#0900330
TUB AND SHOWER FAUCET
SHOWER FAUCET
MODEL #F201E514CP
#F201E521CP
Español p. 13
RR21001

2
PACKAGE CONTENTS
B
A
I
C
G
E
F
D
H
PART DESCRIPTION QUANTITY
AShower Arm 1
BShower Arm Flange 1
C Shower Head 1
D Valve Body 1
E Handle 2
F Escutcheon 2
G Spout 1
H Plug 1
I Screen Washer 1

3
SAFETY INFORMATION
Please read and understand this entire manual before attempting to assemble, operate or install the
product.
NOISE AND WATER HAMMER IN PEX SYSTEMS
As with all plumbing materials under some operating conditions, water hammer can occur in PEX
plumbing systems. The inherent exibility of PEX drastically reduces the magnitude of pressure surges
compared with metallic plumbing materials. Damage to plumbing components in a PEX system due to
these pressure surges is highly unlikely, although noise can sometimes result. Fortunately, there are
solutions to minimize or eliminate water hammer noise.
Clamping or strapping more frequently may help prevent tubing noise. It is very important that the
tubing not be in contact with wallboard, forced air ducts or other high resonance articles. Insufciently
or improperly clamped or strapped tubing may move during xture operation and hit against these
surfaces.
Install a water hammer arrester on xtures where noise is a problem. A water hammer arrester installed
within 6 ft. of the xture on the cold water side only will eliminate the source of the noise (the pressure
wave). It should be noted that even with an arrester, tubing that is clamped or strapped insufciently
may still hit against something as it moves slightly when the water ow is stopped.
Avoid operating xtures in such a way that causes near instantaneous shut off. Simply closing xtures
in a less abrupt manner can eliminate hammer noise.
CAUTION
Inlet ports are designed to allow for 1/2-inch copper tubing solder connection or 1/2-inch IPS threaded
coupling connection. For threaded connections, wrap thread seal tape around threaded ends before
connecting. If soldering connections, remove cartridges, seats, and springs. Connect water supply to
the pipe by soldering. Reassemble cartridges, seats, and springs. Heat damage to these parts may
occur and result in the warranty being void on these parts.
WARNING
• Follow these installation instructions carefully.
• Check local building codes before beginning installation to ensure compliance.
• This product is engineered to meet the EPA WaterSense flow requirement. The flow rate is
governed by the aerator or flow controller. If replacement is ever required, be sure to replace it with
a WaterSense compliant aerator or flow controller to retain the water conserving flow rate of this
product.
• This product might require to be installed with an automatic temperature compensating device to
reduce the risk of scalding and thermal shock. Check with the local plumbing code requirement
before installation. The product should be installed by the local licensed plumber.
• The shower shall be used with automatic compensating valve rated at 1.4 gpm(5.3 L/min) or less.
• If you use soldering for the installation of the faucet, the seats cartridges and washers will have to be
removed before using flame. Otherwise, warranty will be void on these parts.

4
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package
contents list and above. If any part is missing or damaged, do not attempt to assemble the product.
Contact customer service for replacement parts.
Note: This guide is a general representation of the installation process. In the case of plumbing
products, every installation is essentially a custom installation and some adjustments may be required
for your specic application.
Estimated Assembly Time: 90 minutes
Tools Required for Assembly (not included): Safety Goggles, Adjustable Wrench, Thread Seal Tape,
Phillips Head Screwdriver, Channel-Lock Pliers.
• Prior to beginning installation, turn off the cold and hot water lines and turn on the old faucet to
release built-up pressure.
• When installing your new faucet, first, hand-tighten connector nuts. Then, use one wrench to hold
the fitting and a second wrench to tighten the nut an additional 1/4 turn. Connections that are too
tight will reduce the integrity of the system.
22
0-1
0-2
1
D
E
Before installation, remove handles (E) from valve
body (D).

5
1
2
49 3/16 in.
Tub & Shower
30 in.
Shower Only
30 in.
Tub & Shower
48 in.
Shower Only
8 in. Min.
A
E
G
ASSEMBLY INSTRUCTIONS
2. Note the suggested installation distance between
shower arm (A), handle (E), and spout (G).
3. Attach hot and cold supplies to handle valves of
valve body (D). For threaded connections, wrap
thread seal tape around threaded ends before
connecting. Recommended distance from center of
pipe to finished wall is 1-3/4 to 3 inches.
Note: Numbered arrows within steps indicate
sequence of actions.
1. Shut off main water supply before installation.
1
3
1
1
2
3
2
3-1
1-3/4 in.
to 3 in.
D
all

6
ASSEMBLY INSTRUCTIONS
4. Attach vertical shower pipe to the top of the middle
elbow of valve body (D).
4
1
4
2
4-1
all
5. Attach vertical tub pipe to the bottom of the middle
elbow of valve body (D).
Note: Recommend 8 in. minimum distance to spout.
For shower only installation attach plug (H) to the
bottom of the middle elbow of valve body (D) using
thread seal tape.
6. Install stub-out pipe (not included) for spout (G).
Use proper length stub-out pipe so pipe threads will
extend 3-3/4 to 4 inches beyond finished wall.
1
5
1
6
5
6
3
2
5-1
5-2
2
6-1
all
all
D
3-3/4 to 4 in.
H

7
ASSEMBLY INSTRUCTIONS
7. Install shower arm (A) and shower arm flange (B)
to vertical shower pipe elbow.
1
2
7
7
all
B
A
9. Turn on main water supply.
8. Install escutcheons (F) and handles (E) to valve
body (D). Replace screws and install handle
caps.
9
8
1
2
9
8
8-1
D
F
E

8
ASSEMBLY INSTRUCTIONS
10
1
2
10
all
G
10. Check for leaks at tub stub-out pipe. Next wrap
stub-out pipe with thread seal tape and install
spout (G).
11. Check for leaks at shower arm (A). Next divert
water to the shower to flush out the water lines.
12. Install shower head (C) to shower arm (A). Hand
tighten shower head.
11
12
1
11
12
A
A
C
2
12

9
REPAIR INSTRUCTIONS
1. Use a clean strap wrench (not included) to remove
the shower head (C) from shower arm (A).
2. Use a flathead screwdriver (not included) to
carefully remove the screen washer (I).
3. Gently clean the screen washer (I) with a
toothbrush (not included).
IN CASE OF LOW FLOW FROM SHOWER HEAD
2
3
2
1
2
3
1
1
1a
2a
A
C
I
I

10
4
2
2
2
1
2
1
1
2
2
2
REPAIR INSTRUCTIONS
4. Reinstall the screen washer (I) and shower head
(C). Hand tighten shower head. 4
C
1
4a
I
IN CASE OF FAUCET CONTINUALLY DRIPPING
To order a replacement shower cartridge repair kit, call
our customer service department at 1-866-389-8827,
8 a.m. - 8 p.m., EST, Monday - Sunday.
1. Locate and shut off main water supply in your
house. Turn on the shower valve to drain the
remaining water in the shower valve. Remove the
sleeve, stem extension, cartridge, rubber seat and
spring.
2. Install the replacement spring, rubber seat,
cartridge, stem extension and sleeve.
Warning:
The larger end of the spring should be facing
the valve body.
Insert the two cartridge lugs back to back.
1
2
1
1a
2b
2a
Hot Cold
Questo manuale è adatto per i seguenti modelli
3
Indice
Lingue:
Altri manuali Project Source Apparecchio per il bagno

Project Source
Project Source FSI S4PC CROM Manuale utente

Project Source
Project Source 297-2301 Manuale utente

Project Source
Project Source F5120021CP Manuale utente

Project Source
Project Source C14018A-PS Manuale utente

Project Source
Project Source ASCILLIA 13-0082-W-PS Manuale utente

Project Source
Project Source F1A1F506CP Manuale utente