Fig re 1 - Front View
SECTION 1 - SITING
Dimensions
LD1
- 300mm (W) x 645mm (D) x 240mm (H)
Power
Rating
- 3kW
Weight
- 10kg
F se Rating
- 13A
LD2
- 600mm (W) x 645mm (D) x 240mm (H)
Power
Rating
- 7kW
Both Models -
Side/Rear Clearance
- 20mm
Vertical
Clearance
- 900mm
The LD1 and LD2 have been designed in modular form
to allow countertop use or base unit mounting.
Free-standing and base models should be installed
upon a firm, level surface and adjustable feet are
provided for levelling purposes.
ounter units must be positioned upon a table, counter
or similar surface.
Vertical and horizontal clearances required from the top
and sides of a particular unit to any overlying
combustible surface (ie wall, partition, etc) are listed
above. Relevant fire regulations must be complied with.
Mo nting Co nter Units on the Oven
When mounting a counter unit upon a light duty oven, it
is recommended that units which carry liquids, i.e. fryers
and bain marie, are secured as follows:
Remove oven outer back panel and crown plate.
Position unit(s) which require to be secured upon the
oven.
Secure hob unit(s) to oven through side flange centre
holes into the threaded inserts in the base(s) of the hob
unit(s). Use fixings provided (packed separately) and
replace oven back panel.
The unit is now ready for electrical connection.
Mo nting Co nter Units pon a Hotc pboard
Light duty hotcupboards are designed to be used in
conjunction with counter models. Assembly is achieved
by means of two shouldered fixings being applied to the
underside of a top unit from inside a base appliance as
detailed in Figure 1.
SECTION 2 -
ELECTRICAL SUPPLY AND CONNECTION
Electrical ratings are as stated on the unit data plate.
This is based on standard UK specification at 230V -
240V
~
as appropriate. Wiring must be executed in accor-
dance with the regulations listed in this booklet.
WARNING! -
Each individ al appliance m st be earthed!
After completion of installation, the method of operation
should be demonstrated to the kitchen staff. The
isolating switch location, for use in an emergency or
during cleaning should also be pointed out.
LD1 Boiling Top
This model is designed to be connected to a single
phase A supply using the 2 metre mains lead fitted as
standard.
Wires are coloured in accordance with the following
code and should be connected to the plug as follows:
EARTH to terminal marked E or coloured GREEN or
GREEN/YELLOW.
NEUTRAL to terminal marked N or coloured BLA K.
LIVE to terminal marked L or coloured RED.
Units which receive power from a plug, adaptor or
distribution board must be individually protected by a
fuse with an appropriate rating.
For models with two mains leads, each lead requires to
be protected by a fuse with an appropriate rating.
Any replacement supply cable must be 1.5mm
2
, cord
code designation 245 IE 57 ( ENELE H05 RN-F).
For internal connection, outer sheathing must be
stripped 140mm from the cable end. The live and
neutral conductors must be trimmed so that the Earth
conductor is longer by 50mm. Pass inlet cable through
the rear panel cord grip and ensure that the cable is
routed without leaving excessive free length inside the
appliance.
LD2 Boiling Top
This model is designed to be connected to a single
phase A supply. Electrical supply must be installed
using a suitable isolating switch with a minimum contact
separation of 3mm in all poles.