PROLYNX PL-VDIO-05 Manuale utente

IP VIDEO DOOR PHONE QUICK START GUIDE
7” VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT
PL-VDIO-05
W
A
R
R
A
N
T
Y
YEAR
2
P2P
SERVICES
Smartphone Connect
Receive calls, remote monitor and remote unlock
with your smart phone

IP VIDEO DOOR PHONE QUICK START GUIDE
Thank you for purchasing our device!
This quick start guide will help you become familiar with our device in a very short time.
Before installation and operation, please read the following safeguard and warning carefully!
CAUTION
FOR YOUR OWN SAFETY, PLEASE CHANGE SYSTEM’S DEFAULT PASSWORD AFTER YOU FIRST LOGIN!
Welcome
1. Electrical safety
All installation and operation here should conform to your local electrical safety codes. The
product must be grounded to reduce the risk of electric shock. We assume no liability or
responsibility for all the fires or electrical shock caused by improper handling or installation.
2.Transportation security
Heavy stress, violent vibration or water splash are not allowed during transportation, storage and
installation.
3.Installation
Keep upwards. Handle with care.
Do not apply power to the device before completing installation.
Do not place objects on the device.
4.Qualified engineers needed
All the examination and repair work should be done by the qualified service engineers.
We are not liable for any problems caused by unauthorized modifications or attempted repair.
5.Environment
The device should be installed in a cool, dry place away from direct sunlight, inflammable,
explosive substances and etc.
6. Accessories
Be sure to use all the accessories recommended by manufacturer.
Before installation, please open the package and check all the components are included:
Contact your local retailer immediately if something is missing in your package.
Important Safeguard and Warning

TABLE OF CONTENTS
1 Typical Connection 3
1.1 IP Connection Mode 1 3
2 General Settings 4
2.1 Change Default Password 4
2.2 Outdoor Station Settings 5
2.3 Master Digital Indoor Monitor Settings 6
2.4 Digital Extension Indoor Monitor Settings 7-8
2.5 Change Villa Outdoor Station IP via Indoor Monitor 8-11
2.6 Check Results 11
3 Network Camera Settings 12
3.1 Indoor Monitor Settings 12
3.2 Add Network Camera 12
3.3 Add ONVIF Network Camera 12
3.4 Check Results 13
4 Mobile Phone Settings 14
4.1 Outdoor Station Settings 14
4.2 Mobile Phone Settings 14-16
4.3 Check Results 16
5 Installation 17
5.1 Outdoor Station Installation 17
5.2 Indoor Monitor Installation 18
6 Electric Lock and Magnetic Door Lock 19
6.1 Electric Door Lock 19
6.2 Magnetic Door Lock 19
7 Appendix Specifications 20-21

Figure 1- 1.
Note: All the installation and operations here should conform to your local electric safety rules.
When a visitor press call button on Outdoor Station, multiple Indoor Monitors will ring at the same
time. You can call, hang up, and unlock on any of these Indoor Monitors
1. Typical Connection
This mode is for 7”.
Indoor Monitor has one master Indoor Monitor and up to three extension Indoor Monitors. See
Figure 1 1.
1.1 IP Connection Mode 1
3

Figure 2- 1.
Figure 2- 2. 4
The Outdoor Station default IP address is 192.168.1.110. The default WEB account is
User name: admin, password: admin.
The Indoor Monitor default IP address is 192.168.1.109, the project password is 002236.
After the connection, please make sure the Indoor Monitor and Outdoor Station connection are OK.
Please change the default password after your first login.
2. General Settings
Please refer to Figure 2 1 to change Outdoor Station password.
Please refer to Figure 2.2 to change account password, open door password, arm/disarm password,
anti-hijack password of the Outdoor Station (Settings->Password).
2.1 Change Default Password

5
Figure 2- 3.
Figure 2- 4.
Figure 2- 5.
a) Please use the PC to access the Outdoor Station. Open the browser and then input the Outdoor
Station IP address. Click the Enter, input user name and password to login.
b) Now you can set local information. See Figure 2-3.
2.2 Outdoor Station Settings
c) Now you can add digital Indoor Monitor. System has added room 9901 by default. See Figure 2-4.
d) Set network information. See Figure 2-5.

6
Figure 2-7.
Figure 2- 8.
a) On the main Indoor Monitor menu, from System->Project, you can input project password
002236 to go to the project setup interface.
b) Set current Indoor Monitor as the master Indoor Monitor. See Figure 2-7.
2.3 Master Digital Indoor Monitor Settings
c) Click Network on the right pane, and then input master Outdoor Station name, IP address and
enable current function.
Note: Click to go to the extension Outdoor Station interface; you can set extension Outdoor Station
information. You can set several extension Outdoor Stations at the same time. See Figure 2-8.

7
Figure 2-9.
Figure 2-10
a) On the extension Indoor Monitor menu, from System->Project, you can input project password
(002236) to go to the project interface.
b) Set current Indoor Monitor as extension Indoor Monitor.
Step1 Press Product Info, See Figure 2-9
Step2 Press Master, Master icon becomes ‘Extension’ icon.
Step3 Set Room No. (i.e. 9901-1), input IP Address, Subnet Mask and Gateway.
Step4 In Master IP, input IP of the master Indoor Monitor.
c) Click Network on the right pane and then enable current function. See Figure 2-10.
d) Click to go to the next page to set extension Outdoor Station. Enable current function and then click OK.
2.4 Digital Extension Indoor Monitor Settings

8
Figure 2-11.
Figure 2-12.
Note
Please make sure the status is ON.The extension Indoor Monitor can synchronize information with
the master Indoor Monitor. If one master Indoor Monitor has several extension Outdoor Stations,
please enable status as on. See Figure 2-11.
a) On the digital Indoor Monitor interface, from Settings->Project->002236, select Search device.
See Figure 2-12.
2.5 Change Villa Outdoor Station IP via Indoor Monitor

9
b) Change Outdoor Station IP address as 192.168.1.11. See Figure 2-13.
Figure 2-13.
c) Click Add to add Outdoor Station settings. See Figure 2-14
Figure 2-14.
Indice