ProSoft Technology InRAX PC56-HIST LX Series Manuale utente

PC56-HIST-xxxxLX
ControlLogix Platform
In-Rack PC with Data Historian
December 3, 2010
SETUP GUIDE

Your Feedback Please
We always want you to feel that you made the right decision to use our products. If you have suggestions, comments,
compliments or complaints about our products, documentation, or support, please write or call us.
How to Contact Us
ProSoft Technology
5201 Truxtun Ave., 3rd Floor
Bakersfield, CA 93309
+1 (661) 716-5100
+1 (661) 716-5101 (Fax)
www.prosoft-technology.com
support@prosoft-technology.com
Copyright © 2010 ProSoft Technology, Inc., all rights reserved.
PC56-HIST-xxxxLX Setup Guide
December 3, 2010
ProSoft Technology
®
, ProLinx
®
, inRAx
®
, ProTalk
®
, and RadioLinx
®
are Registered Trademarks of ProSoft
Technology, Inc. All other brand or product names are or may be trademarks of, and are used to identify products
and services of, their respective owners.
ProSoft Technology
®
Product Documentation
In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments.
User Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided on the enclosed CD-ROM,
and are available at no charge from our web site: www.prosoft-technology.com
Printed documentation is available for purchase. Contact ProSoft Technology for pricing and availability.
North America: +1.661.716.5100
Asia Pacific: +603.7724.2080
Europe, Middle East, Africa: +33 (0) 5.3436.87.20
Latin America: +1.281.298.9109

PC56 Products
WARNING - EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN
SWITCHED OFF OR THE AREA IS KNOWN TO BE NON-HAZARDOUS.
AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DÉCONNECTER L'EQUIPMENT, COUPER LE
COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DÉSIGNÉ NON DANGEREUX.
Warnings
ATEX Warnings and Conditions of Safe Usage
Power, Input, and Output (I/O) wiring must be in accordance with the authority having jurisdiction
A Warning - Explosion Hazard - When in hazardous locations, turn off power before replacing or wiring modules.
B Warning - Explosion Hazard - Do not disconnect equipment unless power has been switched off or the area is
known to be non-hazardous.
C These products are intended to be mounted in an IP54 enclosure. The devices shall provide external means to
prevent the rated voltage being exceeded by transient disturbances of more than 40%. This device must be used
only with ATEX certified backplanes.
D DO NOT OPEN WHEN ENERGIZED.
PC56™ Battery Warning
PC56 CMOS BIOS settings are protected by a rechargeable battery during power-down situations. The battery must
be fully charged before you change BIOS settings. You must keep the unit powered up for a full 20 hours in order to
obtain full charge capacity. If the battery is not fully charged, changes to BIOS settings may be lost when the PC56 is
removed from its power source. In this situation, the PC56 reverts to its default BIOS settings when power is re-
applied.
If the battery is discharged, or the battery enable jumper is removed, the BAT LED will be illuminated red. A fully
charged battery should maintain the BIOS settings for 15 days without power.
PC56 Markings
Electrical Ratings
Backplane Current Load on PC56: 1 A @ 5 Vdc
Backplane Current Load on IDE: 1 A @ 5 Vdc
Operating Temperature: 0°C to 60°C (32°F to 140°F)
Storage Temperature: -40°C to 85°C (-40°F to 185°F)
Shock: 30 g Operational; 50 g non-operational; Vibration: 5 g from 10 Hz to 150 Hz
Relative Humidity 5% to 95% (without condensation)
All phase conductor sizes must be at least 1.3 mm(squared) and all earth ground conductors must be at least
4mm(squared).
Label Markings
II 3 G
Ex nA IIC X
0°C <= Ta <= 60°C
II - Equipment intended for above ground use (not for use in mines).
3 - Category 3 equipment, investigated for normal operation only.
G - Equipment protected against explosive gasses.

Agency Approvals and Certifications
CE EMC-EN61326-1:2006; EN6100-6-4:2007
CSA/cUL C22.2 No. 213-1987
CSA CB Certified IEC61010
ATEX EN60079-0 Category 3, Zone 2
EN60079-15
243333 ME06

PC56-HIST-xxxxLX ♦ ControlLogix Pl tform Contents
In-R ck PC with D t Histori n Setup Guide
ProSoft Technology, Inc. Page 5 of 29
December 6, 2010
Contents
Your Feedback Please........................................................................................................................2
How to Contact Us ..............................................................................................................................2
ProSoft Technology
®
Product Documentation....................................................................................2
PC56 Products ....................................................................................................................................3
Warnings.............................................................................................................................................3
PC56™ Battery Warning.....................................................................................................................3
PC56 Markings....................................................................................................................................3
1 Installing the PC56 Embedded PC 7
1.1
Package Contents .....................................................................................................8
1.2
Installing Modules......................................................................................................9
1.3
Optional Module Connections .................................................................................10
1.4
Verify Jumper Settings ............................................................................................11
1.4.1
RS-232 (Default) .....................................................................................................11
1.4.2
RS-422 Jumper Setting...........................................................................................11
1.4.3
RS-485 Jumper Setting...........................................................................................12
1.4.4
Cable Connections ..................................................................................................12
2 Connecting Peripherals 19
2.1
Verify Operation ......................................................................................................20
3 Support, Service & Warranty 21
Contacting Technical Support...........................................................................................................21
3.1
Return Material Authorization (RMA) Policies and Conditions................................23
3.1.1
Returning Any Product ............................................................................................23
3.1.2
Returning Units Under Warranty .............................................................................24
3.1.3
Returning Units Out of Warranty .............................................................................24
3.2
LIMITED WARRANTY.............................................................................................25
3.2.1
What Is Covered By This Warranty.........................................................................25
3.2.2
What Is Not Covered By This Warranty ..................................................................26
3.2.3
Disclaimer Regarding High Risk Activities ..............................................................26
3.2.4
Intellectual Property Indemnity................................................................................27
3.2.5
Disclaimer of all Other Warranties ..........................................................................27
3.2.6
Limitation of Remedies **........................................................................................28
3.2.7
Time Limit for Bringing Suit .....................................................................................28
3.2.8
No Other Warranties ...............................................................................................28
3.2.9
Allocation of Risks...................................................................................................28
3.2.10
Controlling Law and Severability.............................................................................28
Index 29

Contents PC56-HIST-xxxxLX ♦ ControlLogix Pl tform
Setup Guide In-R ck PC with D t Histori n
Page 6 of 29 ProSoft Technology, Inc.
December 6, 2010

PC56-HIST-xxxxLX ♦ ControlLogix Pl tform Inst lling the PC56 Embedded PC
In-R ck PC with D t Histori n Setup Guide
ProSoft Technology, Inc. Page 7 of 29
December 6, 2010
1 Installing the PC56 Embedded PC
In This Chapter
Package Contents...................................................................................8
Installing Modules....................................................................................9
Optional Module Connections ...............................................................10
IRQ 15...................................................................................................11
Verify Jumper Settings ..........................................................................11
This Setup Guide will help you get your PC56 Embedded PC up and running. If
you need additional information, refer to the user manual located on the PC56-
HIST CD-ROM shipped with your module.

Inst lling the PC56 Embedded PC PC56-HIST-xxxxLX ♦ ControlLogix Pl tform
Setup Guide In-R ck PC with D t Histori n
Page 8 of 29 ProSoft Technology, Inc.
December 6, 2010
1.1 Package Contents
Your new PC56 Embedded PC is shipped with the following:
PC56 Embedded PC RJ45 to DB-9 Cable
DB-9 Female to 5 Pos Screw Terminal
Adapter
All modules fit into standard slots on the ControlLogix backplane. The PC56
Historian and its IDE module will each take a slot on the ControlLogix backplane.
You will need two available side-by-side slots on the backplane.
To install the PC56 Historian module:
1 Check jumper configurations (page 17, page 11, page 12, page 11) on each
module
2 Insert module in the ControlLogix rack (page 9)
3 Connect your Peripherals (page 19)
4 Verify Boot Up (page 20)

PC56-HIST-xxxxLX ♦ ControlLogix Pl tform Inst lling the PC56 Embedded PC
In-R ck PC with D t Histori n Setup Guide
ProSoft Technology, Inc. Page 9 of 29
December 6, 2010
1.2 Installing Modules
Caution: Although the PC56 Histori n is hot-sw pp ble, it is NOT recommended th t you insert
the module into the r ck while power to the r ck is on. Shut down power to the ControlLogix r ck
before performing this step.
Align the module(s) with the top and bottom guides of the backplane and slide
them into the rack until the module is firmly seated in the backplane connector.
With a firm but steady push, snap the module(s) into place.
If you are inserting multiple modules, make sure that all of the modules are
aligned with their respective slots before you snap them into place.

Inst lling the PC56 Embedded PC PC56-HIST-xxxxLX ♦ ControlLogix Pl tform
Setup Guide In-R ck PC with D t Histori n
Page 10 of 29 ProSoft Technology, Inc.
December 6, 2010
1.3 Optional Module Connections
Optional modules must be connected to the PC56 Embedded PC using a side
connect connection. Refer to the following diagrams:
Insert the side-connect connector into the connector on the side of the PC56 as
shown in the diagram. Be careful when inserting the connector as improper
insertion may cause damage to the pins.
Indice