Protect America Simon XT Manuale utente

This manual is the property of Protect America, Inc. This installation
manual contains condential information which is proprietary to
Protect America, Inc. You may not disclose this information to third
parties and you may not copy all or any part of this installation manual.
The Simon XT Easy Installation Manual

FCC Notices
FCC Part 15 Information to the User
Changes or modications not expressly approved by Interlogix, Inc can void the user’s authority to operate the equipment.
FCC Part 15 Class B
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are
designed to provide reasonable protection against interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause
harmful interference with the radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by taking one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the equipment and the receiver
• Connect the affected equipment to the panel receiver to separate outlets, on different branch circuits
• Consult the dealer or an experienced radio/TV technician for help
ACTA Part 68
This equipment complies with Part 68 of the FCC Rules. Located in this equipment is a label that contains, among other information, the FCC
registration number and the ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone
company.
FCC Part 68 Registration No. B4ZUSA-27621-AL-E REN:0.2B
The REN is used to determine the maximum number that may be connected to your telephone line. Excessive RENs on a telephone line may result in
devices not ringing in response to an incoming call. In most areas, the sum of all device RENs should not exceed ve (5.0). To be certain of the number
of devices that may be connected to a line as determined by the total RENs, contact the local telephone company for products approved after July 23,
2001. The REN for this product is part of the product identier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without
a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.
A plug and jack used to connect this equipment to the premises wiring and the telephone network must comply with the applicable FCC Part 68
rules and the requirements as adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be
connected to a compliant modular jack. See the Installation Instructions for details.
Alarm dialing equipment must be able to cease the telephone line and place a call in an emergency situation. It must be able to do this even if other
equipment (telephone answering system, computer modem, etc.) already has the telephone line in use. To do so, alarm dialing equipment must be
connected to a properly installed RJ31X jack that is electrically in series and ahead of all other equipment attached to the same phone line. Proper
installation is depicted in the following diagram. If you have any questions concerning these instructions, consult your local telephone company or a
qualied installer about installing an RJ31X jack and alarm dialing equipment for you.
If this equipment causes harm to the telephone network, the telephone company may temporarily disconnect your service. If possible, you will be
notied in advance. When advance notice is not practical, you will be notied as soon as possible. You will also be notied of your right to le a
complaint to the FCC.
The telephone company might make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment.
You will be given advanced notice in order to maintain uninterrupted service.
If you experience trouble with this equipment, please contact the company that installed the equipment for service and/or repair information. The
telephone company may ask you to disconnect the equipment from the network until the problem has been corrected or you are sure the equipment is
not malfunctioning.
This equipment may not be used on coin service provided by the telephone company. Connections to party lines are subject to tariffs.
SERVICE
If you have any questions about your security system or if you need service, please contact your security dealer.
Company Name: Protect America
Phone Number: 1-800-951-5111, option 2
Monitoring Number: 1-877-274-0604
2002 GE INTERLOGIX
ITI is a registered trademark of GE Interlogix.
Specications are subject to change. Some features are optional.
Customer Premises Equipment and Wiring
Network
Service
Provider’s
Facilities
Telephone Line
Network
Demarcation
Point
RJ31X
Jack
Alarm Dialing
Equipment
Telephone
Telephone
Telephone
Unused
RJ-11 Jack
Unused
RJ-11 Jack
Computer
Fax Machine
Answering
System

11
Table of Contents
Important
Non-Compliance = No Dispatch
Contents
Easy Installation Steps
Step 1: Package Contents 2
Step 2: Connect the Simon XT 3
Step 3: Familiarize Yourself with the Simon XT 4
Step 4: Set the Clock, Chime, & Alarm 5
Step 5: Install Line Grabbers & Sensors 6
Step 6: Activate Your System 7
Additional Information About Your System
Test Your System Monthly 8
False Alarm Prevention 9
Important Procedures 10
Frequently Asked Questions 11
Sensor Information Worksheet 13
!
An Alarm Permit May Be Required
Some municipalities require third-party verication that an alarm system is registered or that
an application be led; please check with your local police department alarm division.
It is your responsibility to ensure that you are in compliance with all of your city police or
county sheriff's alarm regulations.

Check Package Contents
1
1.2 — Verify Materials
!Find a convenient location for your Simon XT control panel. It should be located
near a phone jack and a non-switched electrical outlet. It should be in a location
that can be accessed easily when entering or leaving the home.
Doors +
Windows Motions Disarm Status
Silent Bypass
Simon
XT
Disarmed
12:23a
PA
S
CK
L
G
P
IN
I
1.1 — Verify Contents
Locate your packing slip. Use your packing slip to verify the contents of
your package.
(1) Screwdriver
(2) 0.5" Screws
per Microsensor
(2) Plastic Wall Anchors
(2) 0.75" Mounting Screws
(1) Plastic Spacer
per Microsensor
(2) Line Grabbers
(Not included with HomePulse)
2

3
Connect the Simon XT
2.2 — Plug in the Power Supply
Make sure you properly secure the power supply to a non-switched and non-GFCI outlet faceplate.
Plug in power supply and secure
with screw provided.
Unscrew the faceplate. Ensure that power supply is secure.
2
Broadband
CLICK
Landline
CLICK
2.3 — Connect the Phone Cord or the Ethernet Cable —
Cellular users skip this step
Standard and Two-Way Voice customers follow the "Landline" instructions. HomePulse Broadband customers follow the "Broadband" instructions.
Locate the phone wire labeled "Wall" on the back of
the Simon XT and plug it into the wall phone jack.
Locate the ethernet cable on the back of the
Simon XT and plug it into your router.
DO NOT PLUG IN YOUR SIMON XT!
You must connect the battery
before
plugging your Simon XT into the wall outlet.
Doors +
Windows Motions Disarm Status
Silent Bypass
Simon
XT
Disarmed
12:23a
CLICK
2.1 — Connect the Battery
Press the two small tabs at
the top of the Simon XT.
Locate the two red wires on the
back of the Simon XT control panel.
Clip the two wires together. The
Simon XT will power on and beep.
OR

4
Familiarize Yourself with the Simon XT
Doors +
Windows Motions Disarm Status
Silent Bypass
Simon
XT
Disarmed
12:23a
Enter
Press to select a particular
menu item or commit to
memory a menu item
that has just been
programmed.
Motions
Press to arm interior sensors.
Siren
The piezo siren is used
for status beeps and
alarms. Fire and intrusion
alarms always sound at
high volume. The volume
of status beeps (such as
trouble or chime beeps,
entry and exit delay
beeps, or auxiliary alarm
beeps) are programmable.
Disarm
Signies the system is
armed when lit. When
illuminated, pressing
the button will prompt
you to enter your
access code to disarm
the system.
Keypad
Twelve-key keypad for
entering access codes or
other numerical data.
*
Turn on lights (additional
equipment is required).
Emergency Buttons
Press and hold button
for two seconds (or press
twice quickly) to notify
the central monitoring
station of a call for help.
Police
Emergency
Emergency
LCD Display
The LCD display can
show a variety of
phrases and icons.
Doors + Windows
Press to arm
perimeter sensors.
Scroll Up /
Scroll Down
Press to scroll
through the menus.
Silent
Press to silence exit
beeps when arming.
Status
Press to check
system status.
Bypass
Press to bypass a sensor.
Speaker
Used for voice output and key
beeps. The Simon XT speaks
arming level changes, system
status, and voice-chime
sensor trips.
#
Turn off lights (additional
equipment is required).
3
3.1 — The Controls

5
Set the Clock, Chime, and Alarm
Setting the Clock
Press SCROLL UP ( ) until the display reads "Set Clock," and then press ENTER ( ).
Enter the master code, then press ENTER twice ( ). If no master code has been set, the default master code is 1234.
The hour should be blinking. Type in the current hour using the KEYPAD then press ENTER ( ).
The minute should be blinking. Type in the current minute using the KEYPAD then press ENTER ( ).
Press SCROLL UP ( ) to select "am" or "pm," then press ENTER ( ).
Press STATUS twice (
Status Status
) to return to the main menu.
Set the Siren
A high-volume siren will sound if there is an intrusion while the system is armed.
Press SCROLL UP ( ) until the display reads, "System Programming," then press ENTER ( ).
Enter the master code, then press ENTER ( ). If no master code has been set, the default master code is 1234.
Press SCROLL UP ( ) until the display reads, "Siren Options," then press ENTER ( ).
Press SCROLL UP ( ) until the display reads, "Panel Piezo Alrm," then press ENTER ( ).
Press SCROLL UP ( ) to select "on" or "off" then press ENTER ( ).
Press STATUS three times (
Status Status Status
) to return to the main screen.
Set the Chime
If the chime is on and the system is disarmed, the Simon XT panel will use voice notication when doors or windows are opened.
When the chime is on, a bell icon is shown on the display.
Press SCROLL DOWN ( ) until the display reads, "Chime," then press ENTER ( ).
Press SCROLL UP ( ) to select “on” or “off,” then press ENTER ( ).
(Note: It is recommended that the chime be turned on while installing sensors.)
Press STATUS (
Status
) to return to the main menu.
4
Programming the Simon XT requires keys to be pressed in order, with little or no
delay. It is recommended that you familiarize yourself with these steps before
beginning. For initial programming, the default master code is 1234 ( ).
The settings below are optional and not required for the Simon XT to operate.

5Install Line Grabbers and Sensors
5.2 — Install Door & Window Sensors
Place marked sensors in their proper location. Additional sensors may be placed to your liking. When placing sensors, make sure that the arrows on
each side are aligned.
3/8in
magnetsensor
Make sure that the sensor and
magnet are within 3/8" of each
other. Use spacers on metal doors
or to aid proper sensor alignment.
Use the provided self-adhesive
velcro to secure the sensor to the
door or window, and the magnet
to the door or window frame.
Determine an appropriate location
for each sensor.
7.5ft7.5ft
Place the motion detector in
the corner of the room, 7½'
above the ground.
Use the self-adhesive velcro to
secure the motion detector
in a corner.
35 ft
Each motion detector protects
within a 35' range in a 90° arc.
5.3 — Install Motion Detector (If Included)
Motion detectors should be placed in the highest-trafc areas of your home, e.g., a living room or a hallway.
CLICK
CLICK
5.1 — Install Line Grabbers (Landline users only) —
DO NOT CONNECT A LINE GRABBER TO THE SIMON XT!
Repeat this step for every phone in the home. For additional line grabbers please contact Protect America at 1-800-951-5111, option 2.
Connect a line grabber to
the wall plug.
Disconnect phone from wall. Connect the phone to
the line grabber.
!Make sure to clean the installation location before applying each sensor.
Upon installing, write the location of each sensor on the "Sensor Information
Worksheet" located on the last page of the manual for future reference.
6

6Activate Your System
Congratulations!
Your system is now installed and ready to be activated.
Post-installation service & support
If you need any help or service after installing your system, call us toll-free at 1-800-951-5111, option 2.
Monitoring
When a proper user code is entered within sixty (60) seconds of an alarm activation, the system is disarmed and
a cancel code is sent automatically to the monitoring station. No further steps are necessary and the monitoring
station will not take action.
If a proper user code is not entered within sixty (60) seconds of an alarm activation, the siren will sound and the
monitoring station will take action.
If an intrusion alarm has been triggered and is not deactivated, the monitoring station will attempt to call and
verify an authorized contact. If there is no answer, if the line is busy, or if the contact does not know the correct
password, then the monitoring station will immediately notify the proper authorities.
Additional Equipment
If you purchased additional equipment that is not found in this manual, please visit us online at
www.protectamerica.com/support for equipment installation guides and manuals.
Call to Activate
Your system is not yet active—you must call Protect
America to activate your system!
When calling, please have your Sensor Information Worksheet and your Packing Slip at hand. A representative will
guide you through the activation process.
Call toll-free:
1-800-951-5111
option 6
If any siren has gone off, disarm the system, then contact the monitoring station
toll-free at 1-877-274-0604.
7

Test Your System Monthly
1) Your monitoring service must be placed in test mode to avoid a false alarm and dispatch of emergency response
personnel. To put your service into test mode contact Protect America.
Central Monitoring Station Customer Service www.protectamerica.com/monthlytest
toll-free 1-877-274-0604 toll-free 1-800-951-5111, option 2 Click for Live Chat
24 Hrs/Day - 7 Days/Wk Standard Hours (Back Cover) Standard Hours (Back Cover)
2) Close all doors and windows and make sure that the status light on your Simon XT is off.
3) Use the keypad to enter the master or a valid user code. Your display should read “System Disarmed” or “Sub
Disarmed” - this ensures that you have a working disarm code. Make sure that you have a working code before
beginning the test.
4) Arm your system: press DOORS + WINDOWS twice (
Doors +
Windows Doors +
Windows
), then press MOTIONS (
Motions
). Your system will
stop beeping when the system is fully armed.
5) Test every sensor on your system using the chart below.
6) Disarm your system using your master or valid user code. The Simon XT should say "System disarmed"
or "Alarm cancelled."
7) Press STATUS (
Status
) to listen to all of the sensors that were activated. Listen carefully to make sure that
every sensor is mentioned. If any sensors are not mentioned, return to step 4 and re-test those sensors.
8) When your control panel has nished speaking the status, press DISARM (
Disarm
) to clear the memory.
9) Contact Protect America to verify that signals were received and to put your monitoring service back
into active mode.
Device
Door / Window Sensor
Keychain Remote
Motion Sensor
Smoke Detector
Simon XT
Emergency Buttons
Open the secured door or window.
Press and hold both the lock and unlock buttons simultaneously
for 2 seconds.
Avoid the motion sensor’s area for five minutes, then enter its area.
Press and hold the “Test” button until the system sounds.
Press and hold each individual button for 3 seconds.
To Trip Device
BROADBAND USERS:
It is highly recommended that you connect a battery back-up (not included) to
your router and modem to prevent system failure in the event of power outage.
8
The siren will sound throughout the test. Do not disarm your system before the
test is complete.