General Settings
Press buttton to Turn on/off the thermostat. When thermostat is turned off, the LCD will only display current temperature reading. When the thermostat is turned off,
press and hold button M for 3 seconds to bring up a configuration menu. In this mode, press button M to select different features’ setting.
Menu # Features description Features Explanation Adjustment (press up or down button to adjust)
01 Model (Model Selection) This thermostat is a combination model allowing you to choose between
3 different models. A, AF and F model. A model: air only, with built in
sensor AF model: air & floor, with both built in and remote sensor F
model: floor only, with remote sensor
A, AF, F
02 Sd (switching differential) The numbers of degree difference before switching. The default is 1°C
which means the thermostat will switch the heating on 0.5°C below the
set temperature and will turn it off 0.5°C above the set temperature. With
a 2°C differential, the heating will switch on 1°C below the set temperature
and will switch off 1°C above the set temperature.
1 = 1 degree(default), 2 =2 degrees
03 ATC (air temp calibrate) This is to calibrate air temperature if required. -1 = decrease 1 degree, 1 = increase 1 degree...
04 FTC (floor temp calibrate) This is to calibrate floor temperature if required. -1 = decrease 1 degree, 1 = increase 1 degree...
05 Maximum floor temperature This is to protect the floor surface by limit the floor temp. (AF model only) 5s, 10s, 15s, 20s (default), 25s, 30s.
06 TR-AF (AF model only)
(TR=Temperature readout)
This gives option to choose to show air temperature,floor temperature or
to show both floor & air in interval.
A=to show air temperature, F=to show floor
temperature, A-F = to show both in 5 second intervals
07 MAXFT (set maximum
floor temp in AF model)
This is to protect the floor surface. 40 degree (default)
08 Clock format This is to set the backlight turning-on time. User can also set the backlight
always on or off.
30 seconds (default) On= always on, OFF= always off
09 TF (temperature format) This alows users to select between °C or °F. °C or °F.
10 Clock 12/24-hour clock system selection 24 (default), 12- hour or 24-hour clock system
11 FP (Frost protection) This is to avoid room temperature goes below 5°C on= activated, off= deactivated
12 SC (setpoint configuration) This allows user to select between 2 sets of default programmed set points. “4” means the 4 programmes will have 4 independent set
temperatures. Each set temperature can be different to the
others. program 3 ; set temperature in program 2 equals
the set temperature in program 4; If set temp in program
1 is changed, set temp in program 3temp in program 2 is
changed, set temp in program 4 will be changed will be
changed automatically to the same set temp as program 1.
If set automatically to the same set temp as program 2.
Please Note: one of the following error messages will appear if one of these problems occur:
LO - This error means that the room or floor temperature is below 0°C
HI - This error means that the room or floor temperature is greater than 50°C
If the floor sensor is short-circuit or broken, the LCD will display “ERR” and the thermostat
will cut off output.
This product should be installed by a qualified electrician.
www.prowarm.com support 0843 770 4597
Optional Remote
Controller Buttons
Optional Remote Controller
(Remote control model only)
1. Turn on/off thermostat
2. Confirm setting
3. Program button
4. Lock or unlock buttons
5. Menu (in OFF mode)
6. Set Day
7. Set time
8. Auto / Manual selection
9. View floor temp (AF model only)
10. Cancel override
11. Vacation mode
12. Decrease the set value
13. Increase the set value