PRULITE.COM 213.746.0360
Prudential Ltg. reserves the right to change design specications or materials without notice. Please visit prulite.com for most current data.
© 2015 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058
WARNING: Ground fixture in accordance with local and national electrical codes. Failure to do so may result in serious personal injury.
62 of
LED Bionic |Recessed Linear
4˝ Slot
INSTALLATION INSTRUCTIONS
CONTINUOUS RUN X3, X7
INSTALLATION
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
2)1) Install aligner splines on housing.
— 2 per joint on Seamless,
Flush and Reg1.
— 4 per joint on Reg3.
Secure xture to structure with wire and all
thread. (Multiple options.)
Mounting Detail (1) Housing Detail for ¼-20
℄
X
Y Y
¼˝ Wiring K.O.
MOUNTING CONVERSION CHART:
* From Centerline
X = 2’ 3’ 4’ 5’ 6’ 7’ 8’
Y =* 9˝ 15˝ 21˝ 27˝ 33˝ 39˝ 45˝
℄
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
3)
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
4)
If additional holes are drilled in top plate for ¼-20 all thread,
support with additional #8 screws at closest locations to
new holes.
Fasten inside joiner brackets on row mounted housings.
8-32 x ⁄˝
Self-tapping Screws
8-32 x ¼˝
Machine Screws
BY OTHERS
WARNING: Failure to properly install top screws will void warranty
OPTION A.
Insert ¼-20 all-thread. Can protrude
into housing no more than ⁄˝
OPTION B.
Hang ¼-20 all-thread or wire from
adjustable hanger bracket
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
5) Slide and tighten aligner splines over joints.
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
LENS
WALL RAIL
LENS REMOVAL TOOL 8-32_X_3_8_HWH_SELF_TAP
ADJUSTABLE HANGER BRACKETS T-BAR BRACKETS OVERHEAD MOUNTING BRACKET
ALIGNER SPLINES “L” Trim
6) 7)
Measure and install
backer anges (X7BF)
at appropriate height.
(Required for X7,
except on pre-
framed sots.)
Install drywall and
self-tapping drywall
screws into X7BF.
Backer ange can
install with up to 2⁄˝
thick hard ceiling
Drywall should be
ush with housing
Drywall screws (by others)
must be ush with drywall
Option to
hang drywall
from backer
ange
SHIPPING STRAPS
07-02-2020