Adding A Detector To An Existing RF Interlink Network
At some point, you might want to add another smoke alarm unit to your existing RF interlink
network for additional protection, or to replace an old unit. Follow the steps in the following table.
User Input Detector Response Timeout
Step 1 2 LINK button presses on any
unit in the network.
Unit will respond with two quick
flashes every 2 seconds if it is the Coor-
dinator of the Network; three quick
flashes every 2 seconds if it is an RFD in
the Network - Join Mode is open.
Join Mode will timeout in 15
minutes
Step 2 Power up unit(s) being added
by connecting the smoke
alarm to the RF baseplate. For
previous units that have been
reset, press button twice to
enter join mode.
Red LED flashes three times every 2
seconds to indicate it is configured (as
an RFD) in the network
Join Mode will timeout in 15
minutes
Step 3 After new unit(s) have joined,
press LINK button twice on
any unit in the network to
close Join Mode.
Red LED on each unit will power off
indicating Standby Mode
Join Mode will timeout in 15
minutes
Step 4 Follow installation instructions
in section 4.
User Input Detector Response Timeout
Step 4 Connect each additional smoke
alarm on its RF baseplate.
Red LED on each unit will initially flash
one second on and one second off.
when each unit joins network and red
LED flashes three times every 2 seconds
to indicate it is configured as an RFD in
the network
Join Mode will timeout in 15 minutes
after last unit joins.
Step 5 After all units have joined,
press LINK button twice on the
baseplate.
Red LED on each unit will power off
indicating Standby Mode
Step 6 Follow installation instructions
in section 4.