PSA Supa8 Manuale utente

SUPA8 Quick Setup & User Manual
CONTENTS
QUICK SETUP & INSTALLATION
FACTORY DEFAULTS................................................................................. 1
INSTALLATION OF THE SECURITY SYSTEM...................................... 2
COMMISSIONING THE DIALLER PANEL ............................................. 5
ZONE INPUT CONNECTIONS.................................................................... 7
PANEL DIAGRAM......................................................................................... 8
USER MANUAL
THE SUPA8 KEYPAD ................................................................................... 9
SUPA8 INDICATOR LIGHTS.......................................................................... 10
KEYPAD BEEPER OPERATION ....................................................................... 10
KEYPAD LOCKOUT ....................................................................................... 11
KEYPAD ENTRY ERRORS .............................................................................. 11
SUPA8 OPERATION ................................................................................... 12
KEYPAD KEY FUNCTIONS............................................................................. 12
OPERATION OF ALL KEYS.............................................................................. 12
HOW TO TURN THE SYSTEM ON.......................................................... 17
AWAY MODE (USING YOUR USER CODE).................................................... 17
AWAY MODE (USING SUPER CODES) .......................................................... 19
HOME MODE (USING YOUR USER CODE)..................................................... 20
HOME MODE (USING QUICK HOME)............................................................ 20
HOW TO TURN THE SYSTEM OFF........................................................ 21
ISOLATING ZONES.................................................................................... 21
PROGRAMMING USER CODES .............................................................. 22
PERSONAL REPORTING.......................................................................... 23
PROGRAMMING TELEPHONE NUMBERS.......................................... 24
OPERATION BY TELEPHONE................................................................. 25
FREQUENTLY ASKED QUESTIONS ...................................................... 26
SYSTEM RECORD SHEET...................................................................... 278

SUPA8 Quick Setup
1
Quick Setup & Installation
Thank you for purchasing the SUPA8 Security Alarm System, the following is intended
to assist you in the installation of the system. Please read these guidelines before
installation.
Note: In some States of Australia special licensing may be required in order to
install Security Alarms and Associated Equipment. Please check with your
local State Authority for details before commencing installation work.
IMPORTANT:
This section is a brief outline of installation and programming. For additional
information refer to the SUPA8 Installer Manual.
Factory Defaults
THE SUPA8 ALARM SYSTEM COMES FROM THE FACTORY PROGRAMMED AND
READY TO GO. BEFORE MAKING ANY CHANGES, CHECK WHAT IS ALREADY
PROGRAMMED, AS THEY WILL MOST PROBABLY SUIT YOUR NEEDS.
MASTER USER CODE : 1 2 3 4
INSTALLER CODE : 2 5 8 0
ENTRY TIME : 30 seconds
EXIT TIME : 60 seconds
SIREN TIME : 5 minutes
ZONE TYPE Zone 1 : Entry Delay - enables entry exit timer.
Zone 2 : Handover - enables exit timer and entry timer
if Entry Delay Zone entered first.
Zone 3 : Handover - enables exit timer and entry timer
if Entry Delay Zone entered first.
Zone 4 : Instant - immediately sounds siren if violated
when system is armed.
Zone 5 : Instant - immediately sounds siren if violated
when system is armed.
Zone 6 : Instant – immediately sounds siren if violated
when system is armed.
Zone 7 : 24 Hour - sounds sirens if violated whether
system is armed or disarmed.
Zone 8 : 24 Hour - sounds sirens if violated whether
system is armed or disarmed.
NOTE: When Armed in Home Mode Zones 5 and 6 has been programmed to be
isolated.

SUPA8 Quick Setup
2
Installation of the Security System
Step 1:
Plan out location of all components supplied in your kit as follows:
Suggested Locations for Equipment Mounting
(a) The 8 Zone Master Panel Box should always be located out of sight (i.e.
cupboard, wardrobe or in an area it would not be easily seen).
(b) The 8 Zone Keypad should be situated near the main entry/exit point (usually
inside the main front door).
(c) The External Siren (enclosed in siren cover along with Tamper Button)
should be mounted in a prominent position in full view. This would normally
be mounted under the eaves at the front of the house in a corner position. The
strobe light is mounted onto the siren cover.
(d) The Flush Mount Reed Switches are most suitable to be mounted on the front
and back doors.
(e) The Passive Infra Red Detectors (PIR’S) should be situated to cover high
access areas (eg: Hallways and areas of high importance or value).
(f) The Emergency Button should be located in a position for quick easy access
in an emergency or panic situation (suitable position could be a bedside
location).
(g) The Pinkerton Security Alarm Warning Stickers should be placed on the front
face of the Siren cover and on an outside window in clear view.
Note: PIR’s are susceptible to environmental conditions such as wind and air
movement. Windows must be closed when system is armed to avoid possible
false alarms.
Step 2:
(a) Install all cabling to component positions.
(b) Austel approved cables must be installed if the system is to be monitored.
Use two pair (4 core) 14/0.20 and Figure 8 (2 core) 14/0.20.
REMEMBER TO MARK YOUR CABLES.

SUPA8 Quick Setup
3
Step 3:
(a) Mount devices in the most suitable locations (as suggested in Step 1).
(b) Wire cabling directly into devices.
(c) At this point install the 4.7K End of the Line (EOL) Resistor.
(Refer to Page 7).
The feature of this resistor is that when installed at the furthest point in the Zone,
tampering or interference with the wiring is not possible without setting off the alarm.
Note: All joints connecting cables to EOL Resistors must be soldered and taped.
Step 4:
(a) Install Master Control Panel and connect all cabling to panel.
(b) A 240V GPO is required adjacent to the Master Control Panel position for the
Plug Pack.
Step 5:
Seal any unused or spare Zones with a 4.7K (EOL) end of line resistor.
Step 6:
Connect Battery, now Switch on Plug Pack supply.
Note: Once the alarm system is powered up, control of the system is handed over,
and managed by the 8 Zone Keypad. All programming for the system is done
via the Keypad.
Step 7:
Upon power up the Zone 3 LED will be on, and the ON-LINE LED will also be on
indicating a system self test.
After the alarm panel has initiated this tests the panel will go into alarm if Zones 7 & 8
(24 hour Zones) are not sealed.

SUPA8 Quick Setup
4
To DISARM the panel:
(a) On Keypad
Enter: 1234 (all Zone lights will flash)
(b) Followed by: 0(the off key)
Step 8: Walk Test
To check operation of all Zones a Walk Test is recommended.
(a) On Keypad
Enter: 1234(all Zone lights will flash)
(b) Followed by: 5(to initiate a walk test)
The walk test function is now activated.
The Zone LED will light as each Zone is triggered and the siren will squawk momentarily. The
Zone LEDs will remain on to show which Zone has been violated. (Requires only one person
testing).
To deactivate a walk test press the *key.
THE SYSTEM IS NOW OPERATIONAL
To arm and disarm the system enter Master User Code 1234 (factory default) followed
by
To arm the system enter: 9(ON)
To disarm the system enter: 0(OFF)
Note:The system can also be quick armed by pressing #9
To disarm enter User Code then 0
To change Master User Code or User Codes, please refer to Page 22
This completes the instruction for a Local Panel

SUPA8 Quick Setup
5
Commissioning the Dialler Panel
Austel Requirements:
Austel requirement’s state that all Dialler Panels connected to the Telephone Network must have
the Telephone connection and termination work performed and completed by a current Austel
Licence Holder.
To Assign for Local Dialling (to a nominated telephone number) for Self
Monitoring Purposes.
Step 1: On Keypad
Enter programming mode: 2580 7
You are now in Programming Mode (ON-LINE light will flash).
Step 2: On Keypad
To set up Personal Reporting format:
Enter: 250 (address number)
Followed by: 2578 (cancels the programming mode)
Step 3: On Keypad
Re-enter programming mode:
Enter: 2580 7
Step 4: On Keypad
Entering of required telephone number/s.
1st Telephone Enter: 128 0391234567 #6 *
2nd Telephone Enter: 144 0411234567 #6 *
Note: (a) The above numbers are examples only. You must enter the correct numbers to dial
according to the Home owner’s requirements. A maximum of two telephone numbers
can be programmed.
(b) The phone numbers can consist of a mix of mobile phones numbers and local phone
numbers. Only one phone number can be programmed if required.
(c) #6 is used to finish the phone number.
(d) *completes address (allows next address).
Step 5: On Keypad
Exit programming: Enter: *

SUPA8 Quick Setup
6
System is now operational as a Self Monitored Dialler.
Note: In the event of an alarm, the dialler will emit via the telephone system, a computer
generated siren tone.
If you are installing a Dialler Panel and do not wish to connect to a telephone line, you
MUST default the panel to a local format. (See page 7 of Installer Manual)
To Assign for Pinkerton Security Central Monitoring Station Dialling.
There are two formats that can be selected for central station monitoring; domestic monitoring and
business monitoring. The difference between domestic and business monitoring is that business
monitoring will send opening and closing reports.
Before commencing programming please contact Pinkerton Monitoring Pty Ltd on (03) 9888 9889
for allocation of Dialler Telephone Numbers and Client Identification Number.
Step 1: On Keypad
To enter programming mode.
Enter: 2580 7
You are now in Programming Mode (ON-LINE light will flash).
Enter: 250 3578 (for domestic monitoring)
or
250 4578 (for business monitoring)
Step 2: On Keypad
Re-enter programming mode:
Enter: 25807
Step 3: On Keypad
To program Central Monitoring Station Telephone Number:
Enter: 128 0391234567 #6 *
Enter: 144 0391234567 #6 *
Note: (a) The above number 03 91234567 is an example only.
(b) If you are only supplied with one central station number please enter
that number into both telephone addresses.
(c) #6 is used to finish the phone number.
(d) *completes address (allows next address).

SUPA8 Quick Setup
7
Step 4: On Keypad
To assign Client Identification Account Number (example No:1111).
Enter: 160 1111
Enter: 164 1111
Note: The Account Number must be programmed into both addresses.
The above Account Number is allocated by your Central Monitoring Station.
Enter: *(to exit programming mode).
This system is now operational as a Central Monitoring Station Dialler.
Zone Input Connections
General Examples Only. Refer to installation guidelines supplied with device.

SUPA8 Quick Setup
8
Panel Diagram
1
6VAC

SUPA8 User Manual
9
User Manual
The SUPA8 Keypad
The SUPA8 Keypad controls the operation of the SUPA8 alarm panel. It uses
a series of command entry keys to input codes that can arm, disarm and
program the system. The soft-touch rubber keypad is concealed behind a
hinged lid and a series of System and Zone lights run down the right-hand side
of the fascia.
Indice
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente