PULSE+ ROIP-400 Manuale utente

1
Package Contents:
1. Radio Over IP Gateway (ROIP-400)
2. Ethernet Cable
3. Radio Interface Cable
4. Power Adapter 9V DC
5. Quick Startup Guide
ROIP-400
Operation Manual
Version 6.0.0.1
RADIO OVER IP GATEWAY

2
INDEX
BASIC INSTALLATION ……………………………...….………...3
Hardware Interface Overview …….……………………….3
Hardware Front Overview …………………………….…..3
ROIP Quick Setup ………………………………………...5
SETTINGS CONFIGURATION ……………………………….......6
Computer IP Configuration ………...…………....…....….6
Factory Default ROIP Settings …………...………….…....9
ROIP Configuration …….……………………………..…..9
Local IP Settings Configuration ………..……….……….10
Change Login Password ….…..…….….……….…….….11
Radio Settings Configuration …….………………….…..12
Radio Group Configuration …………………………….13
Server Settings Configuration ……..……….……....……14
Reset ROIP to factory default ……….…..………….…...15
SYSTEM CONFIGURATION …………………………………. .16
Point to point configuration… …………………….….…16
Two or More Systems at different locations …….16
Two Systems at same location ……..…………...17
ROIP Server Configuration…..….. ……………………..18
One or more system at same location…………….18
One or more system at different location………...18
VOX Mode Configuration ……………………………....19
Multi Radio connection over single ROIP………………19
WAN IP Locator ………………………………………..20
Cross and Straight Cable Connections …………….……21
RADIO CONFIGURATION ………………………………...…....22
Interface Cable Connections …………………...…...…...22
Connecting to Motorola GM338 ………………………...22
Radio Programming ……………………………………..23
QUICK TROUBLESHOOT ………………………………...….…24
DTMF COMMANDS ……………………………………………..25
ROIP-400 Operation Manual
Copyright 2017@ Pulse Communication Systems Pvt. Ltd.

3
ROIP-400 Operation Manual
BASIC INSTALLATION
Hardware Interface Overview
CONNECTOR
TYPE
INTERFACE DESCRIPTION
Power connector Power interface Power connector to provide
external DC power supply to
ROIP
Ethernet (RJ45) LAN interface LAN port provides LAN con-
nectivity with other ROIP or
Computers.
Radio connector
(RJ45)
Radio interface Radio connector to interface
with Radio Set
Hardware Front Overview
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
RADIO CONNECTOR
LAN CONNECTOR
POWER
CONNECTOR
LAN CONNECTION LED

4
ROIP-400 Operation Manual
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
LED COLOR STATUS DESCRIPTION
PWR
Red
ON System Power ON
OFF System Power OFF
LINK
L1/L2
&
L3/L4
L1-Red
Fast Blinking Not connected to
Server
ON (constant) Connected to Server
L2-Green
Fast Blinking Not connected to
Server
ON (constant) Connected to Server
L3-Red
Fast Blinking Not connected to
Server
ON (constant) Connected to Server
L4-Green
Fast Blinking Not connected to
Server
ON (constant) Connected to Server
RED
(PTT)
ON Radio Set Connected
is Transmitting Au-
dio
GREEN
(CSQ)
ON Radio Set Connected
is Receiving Audio
R1/R2
OR
R3/R4
* L1/L2/L3/L4 are dual LED's

5
ROIP-400 Operation Manual
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
ROIP Setup
Plug power Adapter (9v DC) into ROIP .
Connect one end of the Ethernet cable to the ROIP and other end to the
Computer / Laptop/ switch Hub.
Check LAN connection LED (Green Color) is glowing continuously. If
it’s Blinking , check your Ethernet cable.
4 Radios are respectively connected with one 400 ROIP .There are four
RJ-45 connectors to connect radio set (RA1, RA2, RA3, RA4).
Connect RJ-45 part of interface cable at the radio connector end of the
ROIP . Connect the other end to the accessory port of the Radio Set .
Attach Antenna to the Radio and fix it outside the building or room
at the roof. Power on the Radio.
Take a walkie talkie-1 at the same channel/ frequency as of Radio
set-1 similar as all walkie talkie as per respective Radio’s.
Speak from the walkie talkie-1 Radio Set-1 should receive the sig-
nal and CSQ Led R1 (green color) at the front of the ROIP should
glow. Similarly speak from the mic of the Radio Set –1, walkie
talkie-1 should receive the signal.
Setup another ROIP and Radio’s and Walkie Talkie’s in the similar
way.

6
SETTINGS CONFIGURATION
Computer IP Configuration to configure ROIP
Go to Control Panel-> Network and Internet->
Network and Sharing Center
Click on Local Area Connection/ Wireless Network Connection.
Click “Properties”
ROIP-400 Operation Manual
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.

7
ROIP-400 Operation Manual
Select “Internet Protocol Version 4 TCP/IPv4” and Click
“Properties”
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.

8
ROIP-400 Operation Manual
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
Select “Use the following IP address” option.
Enter IP Address of computer (should be in the same local network
range as of ROIP). If ROIP is in default mode, enter “192.168.1.x”
(x is any value from 1 to 254 other than 80)
Enter Subnet Mask. If ROIP is in default mode, enter
“255.255.255.0”
Enter Default Gateway. If ROIP is in default mode, enter
“192.168.1.1”
Click Ok to save settings.

9
ROIP Configuration
Connect ROIP to a computer/ laptop using Ethernet Cable and fol-
low “Computer IP Configuration” procedure.
Open a Web browser (Internet Explorer, Mozilla Firefox, Chrome,
etc) on the computer.
Enter the Local IP address of the ROIP on the address bar of web
browser as shown below (factory default: “192.168.1.80”:
ROIP-400 Operation Manual
Factory Default ROIP Settings
IP Settings:
Local IP: “192.168.1.80”
Subnet Mask: “255.255.255.0”
Gateway: “192.168.1.1”
Password: “admin” (without using “”)
A Login page will appear as shown below. Enter login password
and press Login (factory default: admin).
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.

10
ROIP-400 Operation Manual
Radio Over IP Gateway Settings Home Page will appear as below.
IP Settings Configuration
Select “Local Ip Config Settings” on the Home Page.
A Local IP Configuration Settings Page will open as shown below.
Modify values as mentioned in “System Configuration”
Click on Save to confirm the changes.
Reset Power of ROIP for changes to take effect.
Local IP: Ip Address of the ROIP in the local area network
Subnet Mask: Subnet Mask of the local area network
Gateway: Ip Address of the gateway of local area network
Copyright 2017 @ Pulse Communication Systems Pvt. Ltd.
Indice
Altri manuali PULSE+ Portale
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente