PXM PxArt+ 6 Manuale utente

MANUAL
PX390
PxArt+ 6
R

TABLE OF CONTENTS
1. General description....................................................................................................
2. Safety conditions........................................................................................................
3. Version data...............................................................................................................
4. Lamp description........................................................................................................
5. Manual change of lamp settings................................................................................
6. Co-operation with the PX277 configurator.................................................................
6.1 Description of the information parameters.................................................
6.2 Setting lamp parameters...........................................................................
6.2.1 Lamp colour and brightness address....................................................
6.2.2 Invert colour...........................................................................................
6.2.3 Flicker - Free.........................................................................................
6.2.4 Smoothing.............................................................................................
6.2.5 Smoothing time.....................................................................................
6.2.6 Restoring default settings......................................................................
6.2.7 Response to the lack of DMX signal.....................................................
7. DMX signal and power supply connection.................................................................
7.1 GLOBAL Trac GAC 600 adapter...............................................................
7.2 Section through the DMX bus-duct............................................................
8. RDM description of available parameters..................................................................
9. Device programming..................................................................................................
10. Dimensions..............................................................................................................
11. Technical data..........................................................................................................
Declaration of conformity...............................................................................................
3
3
5
6
7
8
9
9
9
10
10
11
11
11
12
13
13
13
14
16
17
18
19
Manufacturer reserves the right to make modifications in order to improve device operation.
PXM Marek Żupnik spółka komadytowa
ul. Przemysłowa 12
30-701 Kraków
tel.: (12) 626 46 92
fax: (12) 626 46 94
E-mail: [email protected]
Internet: www.pxm.pl
Rev 1.1
for Firmware 2.19

3
1. GENERAL DESCRIPTION
2. SAFETY CONDITIONS
Caution! Before installing, connecting, using and maintaining the lamp, you
must absolutely read this document.
The following symbols are used to emphasise important information on security conditions on
the product and in this manual.
Danger!
Risk of loss of life and
health.
Warning!
Fire hazard.
Warning!
LED light emission.
The risk of eye
damage.
Warning!
The risk of burns.
Warning!
Read this instruction
manual.
Do not look at the LEDs at a shorter distance than 2.0 m from the front surface of the
tube without proper eye protection. At a shorter distance, LEDs can cause damage or
eye irritation. Do not look at the light source directly through any optical instruments,
which focus the light rays.
Caution!
PxArt+ 6 is a professional LED illuminator designed for illumination of museum exhibitions or
displays.
Thanks to the application of the most modern semiconductor SSL LED light sources and
advanced control electronics, a high class illuminator was created which meets very high
requirements for museum and exhibition lighting. Its most important advantages include a
complete lack of ultraviolet radiation emission, trace amounts of infrared radiation, a very high
factor of CRI colour capturing, smooth adjustment of colour temperature of emitted light, large
brightness and small energy consumption.
®
The device features a base which allows for mounting it in GLOBAL Trac Pulse control bus bars,
provided with an additional control line.
Two individual addresses allocated to each lamp allow for independent adjustment of its
brightness and colour temperature, regardless of the settings of other lamps.
Through push buttons located on the lamp casing it is possible to operate it manually (e.g. in case
of connecting the lamp to bus bars without a control line).
®
Highly-effective LEDs made by Osram Oslon are used in the lamp with an efficient control
system, through which the lamp emits small amounts of heat.
The lamp casing renders it possible to change the direction of its beaconing in two axes.

PX390 is powered directly from a standard 230 V grid. Failure to observe safety instructions may
result in electric shock and pose a threat to life.
Therefore, it is necessary to observe the following rules:
1. Installation should be performed by a person holding the appropriate qualifications, according
to the instruction manual.
2. Lamp can be connected only to a grid which meets the safety conditions (3-wire grid, equipped
with a circuit breaker).
3. Protect all cables against mechanical and thermal damage.
4. In case of failure of any of the cables, it must be replaced with a cable of the same technical
parameters.
5. All repairs can only be carried out with power disconnected.
6. The device with visible mechanical damage cannot be connected to the mains.
7. Avoid sudden shocks, particularly dropping.
8. The device must not be used in rooms with a temperature below 2 °C or above 40 °C.
9. Clean only with a damp cloth – the lamp must be at this time completely disconnected from the
power supply.
In case of improper usage of the product it may cause a risk of serious injury or death,
because of the threat of fire.
While working outdoors in normal conditions, the housing unit can heat up to +60°C.
Make sure that accidental contact with the device during use is impossible.
4
From a distance of more than 2.0 m from the outer housing of the lamp and LEDs, the light is
harmless to unprotected eyes.

There are several versions of the PX390 lamp which are different from each other as far as
the type of the reflector applied.
Below there is a description of designations of PX390 models with explanation:
PX390-XX-YY-Z
XX - the reflector angle
Available values:
o
10 - 10
o
20 - 20
o
30 - 30
o
40 - 40
EL - elliptical
YY - colours of applied LEDs
MW - multi white (dynamic white)
MC - color (RGB)
Z - housing colour
1 - grey
2 - black
3 - white
Example of lamp designation:
PX390-20-MW-1
3. VERSION DATA
5
Lamp catalogue number
The reflector angle: 20°
Colour of applied LEDs:
dynamic white
Lamp housing colour: grey
The dimming of the lamp brightness occurs when the temperature is above 70 °C; this prevents
the device from overheating. If the device reaches a temperature of 90 °C, the power of the lamp
will be totally reduced. The light is then switched automatically in the event of temperature drop
below the maximum temperature (90°C). The higher the temperature of the device, the greater is
the brightness dimming.

4. LAMP DESCRIPTION
6
o
360
1 3
4
5
1
2
3
4
a 3-phase track for GLOBAL
®
Trac Pulse control
2
end feed
power cable
DMX cable (shielded cable, 2-core
cable)
GLOBAL Trac GAC 600 adapter
5
DMX+ DMX-
GND

The lamp has been equipped with buttons which allow for changing the brightness level and
colour temperature of light. The buttons have been placed at the bottom part of the junction box,
above the lamp reflector. One button is responsible for one parameter.
The available buttons and connector for connecting the PX277 programmer have been shown in
the figure below:
7
Above the reflector there is a diode which indicates the condition of the lamp.
Depending on a situation, the diode signals the following:
! start of the lamp – quick flickering of the diode for 2 seconds,
To change the brightness or temperature colour, press and hold down the appropriate control
button. If during the brightness or colour temperature adjustment the button diode starts
flickering, it means that the extreme value (minimum or maximum) has been reached. Then the
direction of adjustment changes.
It is possible to change the adjustment direction without reaching extreme values. For example,
while the lamp brightness is increased, release the control button for a moment. The diode will
signal the change of adjustment direction. The pressing of the adjustment button again will cause
the dimming of the lamp (brightness decrease).
While the lamp operates, the diode stays switched off (excluding situations mentioned above).
For lamps with RGB LEDs configuration, programming buttons available under the reflector have
the following functions:
! DMX signal receiving – slow flickering of the brightness adjustment button (1Hz frequency) in
the first minute after receiving the DMX signal,
! after the start of the lamp in case of the loss of DMX signal – diode lights (continuously) for 1
minute,
! if the state of DMX signal is changed (if there was no DMX signal and it returned, or vice
versa) – diode signals it for 1 minute,
! damage of the temperature sensor module – diode does not go out after 1 minute.
ź colour temperature adjustment button - change of light colour
ź brightness adjustment button - change of the brightness value
5. MANUAL CHANGE OF LAMP SETTINGS
Parameter programming
connector (using PX277)
Brightness adjustment
Colour temperature
adjustment

6. CO-OPERATION WITH THE PX277 CONFIGURATOR
Lamp settings can be changed by connecting the PX277 PxArt Settings Controller configurator.
At the moment of connection, the PX390 starts again which causes LEDs to be off for a while and
the diode indicating the DMX signal condition pulses for 2 seconds.
When the device is turned on, its name appears on the display. The main menu allows a preview
of many lamp parameters from PxArt series and a change of the following options: colour and
brightness address, scene brightness and colour, colour inversion, smoothing, change of
smoothing time, Flicker free and restoration of default parameters.
Furthermore, it is possible to check the lighting time and lamp operation time (total lamp operation
time, also without switching the diodes off). Additionally, information concerning minimum,
maximum and current temperature reached by the lamp is displayed.
PxArt Settings Controller also allows for checking the version number of the software which is
installed in the lamp, its serial number and model.
Navigating through the menu is possible with programmer buttons located below the display. The
"escape" button allows an exit to the upper level in the device menu; "next" and "previous" buttons
make it possible to go forward and backward (alternatively value decreasing or increasing).
However, the "enter" button allows you to enter the edition of the selected menu or to confirm the
edited value.
Lamp
parameter value
DMX signal value
Colour temperature
adjustment (Lamp colour)
Brightness adjustment
(Lamp brightness)
4500K
100%
3600K
50%
255
255
2700K
128
0
0%
128
0
Setting lamp parameters - DMX signal value:
8
Invert colour
Turning off
Invert colour
Turning on
0
128
255

6.1. Description of the information parameters
PX277 controller allows you to read important information concerning the lamp to which it has
been connected.
Model
PX390 +6 MW
Temp. min max
23.0°C 53.3°C
Current temp.
25.5°C
Lighting time
00y 001d 06h:48m
Working time
00y 000d 07h:00m
10x NEXT
NEXT
NEXT
NEXT
Serial Number
2015210005
Version
ver 2.19
NEXT
NEXT
Lamp serial number
Lamp operation time (total operation time of the lamp, also
without diodes turned on) and lighting time are presented as
follows (designations from the left):
- years (numbers next to letter "y”),
- number of days (letter "d”),
- hours (letter "h”),
- minutes (letter "m”).
Version number of the software
installed in the PX390 lamp
Lamp model
Information concerning the minimum, maximum
and current temperature reached by the lamp.
A unit expressed in [°C]
6.2 Setting lamp parameters
6.2.1 Lamp color and brightness address
PX277 allows for changing the DMX address which controls the color and brightness of the lamp.
The lamp has the DMX channel assigned whose value can be changed depending on the needs.
DMX channel can be set between 1 to 512.
To change the DMX channel (which is
responsible for the lamp function), select in the
PX277 menu a [Color address] or [Bright.
address] option, confirm by pressing "enter"
and then set an appropriate value using
"previous" and "next" buttons. After the change
of the DMX channel, the operation has to be
confirmed by pressing "enter".
Color address
001
Color address
001 *
ENTER
Color address
512 *
NEXT
Model
PX390 +6 MW
NEXT
9

6.2.2 Invert color
Invert color
Off
Invert color
Off *
ENTER
Invert color
On *
NEXT
Model
PX390 +6 MW
5x NEXT
The [Invert color] function applies both to
normal operation of DMX and operation in no
signal mode.
Enabling this option results in changing the
DMX interpretation according to the
scheme:
Value: 0 Value: 255
Warm white Cold white
SWITCHING ON
THE FUNCTION
Invert color
Value: 0 Value: 255
Cold white Warm white
6.2.3 Flicker-Free
Flicker free
On
Flicker free
On *
ENTER
Flicker free
Off *
NEXT
Model
PX390 +6 MW
6x NEXT
The “Flicker free” technology allows for
avoiding an unpleasant flickering of light
during video recording.
Bright. address
001
Bright. address
001 *
ENTER
Bright. address
512 *
NEXT
Model
PX390 +6 MW
2x NEXT
10
Altri manuali per PxArt+ 6
1
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali PXM Proiettore

PXM
PXM PxArt+ 06 Mono Track Manuale utente

PXM
PXM Ceiling PxArt+ 12 Manuale utente

PXM
PXM PxAqua 3 SF Manuale utente

PXM
PXM Ceiling PxArt+ 12 Manuale utente

PXM
PXM PxArt+ 6 Manuale utente

PXM
PXM PxArt+ XL Mono Ceiling Manuale utente

PXM
PXM PxArt+ 3 Manuale utente

PXM
PXM PxSpotBar Manuale utente

PXM
PXM Mono Track PxArt+ XL Manuale utente

PXM
PXM PxArt+ 06 Mono Track Manuale utente