MT VERNON-AE TROUBLE SHOOTING MANUAL
7020-057D9-30-2010
CONTROL BOARD
SRV7000-456 Rev C
CONTROL BOARD SPECS 7.6 CODE: (Rev 3 fuel tables)
FUEL UFTI SS LOW SS MED MAX IGNITER TIME A/C CYCLE TIME SHUTDOWN TIME
CORN: 0 12 MIN 12 MIN START+15 MIN 2.9 HRS* 6 MIN
UTILITY PELLET: 1 4 MIN 5 MIN START+2 MIN 1.2 HRS* 10 MIN
SOFTWOOD: 2 4 MIN 5 MIN START+2 MIN 2.7 HRS* 10 MIN
SUNFLOWER SEEDS: 3 4 MIN 5 MIN START+4 MIN 2.4 HRS* 10 MIN
WHEAT: 4 9 MIN 8 MIN START+13 MIN 2.6 HRS* 10 MIN
HARDWOOD PELLET: 5 4 MIN 5 MIN START+2 MIN 2.2 HRS* 10 MIN
*NOTE: AUTOCLEAN CYCLES TIMES ARE ESTIMATED WHEN THE UNIT IS RUN AT THE “HIGH” OUTPUT SETTING.
UPDATES:
SRV7000-323
ECO 56401 --- CHANGED FROM 6.9 TO 6.10A CODE. INSTALLED POWER STROKE CODE FOR AUTOCLEAN AND
CHANGED TO THE “QUIET” CONVECTION BLOWER CURVE. REV 2 FUEL TABLES ALSO INSTALLED. (1-11-07)
SRV7000-330
ECO 56476 -- RELEASED WITH THE 7.2 CODE. HIGH ELEVATION FUEL TABLES INSTALLED. 2 CONVECTION BLOWER
SPEED OPTIONS INSTALLED, 135 & 165 DEGREES TO GET TO THE HIGH BLOWER SPEED & EXHAUST BLOWER STAYS
ON DURING THE AUTO-CLEAN CYCLE AND 20 MINUTES AFTER AUTO-CLEAN IS COMPLETED. (8-2-07 // SN 0072232364
INSERT /// SN 0072279399 FS)
SRV7000-456
ECO 58315 -- RELEASED WITH THE 7.3 CODE. MADE SOME UPDATES TO THE EURO FUEL TABLES. (They can be
accessed by turning the rotary switch to position 1)
REV B --- RELEASED WITH THE 7.4 CODE. ADDRESSED PREVIOUS AUTO-CLEAN PROBLEMS. SN 00700200343
REV C --- RELEASED WITH THE 7.5 CODE. ADDRESSED LOGIC PROBLEM WITH VAC SWITCH & AUGER JAM.
REV C ---RELEASED WITH 7.6 CODE. INSTALLED REV 3 FUEL TABLES. 4-6-09 ECO 60611.
REV (pending) ---RELEASED WITH 8.0 CODE. INSTALLED REV 4 FUEL TABLES. (still testing)
PAGE 7
CONTROL BOARD SPECS 8.0 CODE: (Rev 4 fuel tables)
FUEL UFTI SS LOW SS MED MAX IGNITER TIME A/C CYCLE TIME SHUTDOWN TIME
CORN: 0 10 MIN 10 MIN START+10 MIN 2.9 HRS* 6 MIN
UTILITY PELLET: 1 4 MIN 5 MIN START-UP ONLY 1.2 HRS* 10 MIN
SOFTWOOD: 2 4 MIN 5 MIN START-UP ONLY 2.7 HRS* 10 MIN
SUNFLOWER SEEDS: 3 4 MIN 5 MIN START+4 MIN 2.4 HRS* 10 MIN
WHEAT: 4 9 MIN 8 MIN START+10 MIN 2.6 HRS* 10 MIN
HARDWOOD PELLET: 5 4 MIN 5 MIN START-UP ONLY 2.2 HRS* 10 MIN
*NOTE: AUTOCLEAN CYCLES TIMES ARE ESTIMATED WHEN THE UNIT IS RUN AT THE “HIGH” OUTPUT SETTING.