RAB Lightcloud LCGATEWAY Manuale utente

EZPAN EDGELIT PANEL 2X2
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
Access Plate
Conduit Knockouts
SAFETY INSTRUCTIONS
WARNING: Risk of re or electric shock. Suitable for Damp locations.
WARNING: Suitable for 9/16” or 15/16” Flat Tee Grid in both Insulated Ceilings and Non-Insulated Ceilings. Access above
ceiling required.
WARNING: Do not handle energized xture when hands are wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90° C.
WARNING: Fixture to be independently supported to building structure.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding
is required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A
PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
Make certain power is OFF before installing or maintaining xture.
Fixture
Grid Clip (4)
Tee-Grid
Bar
Access Plate Screw
Splice Box
2
Grid Clip
Hole
Grid
Clip
Power
Feed
Fixture Firmly bend Grid
Clips up and out
RECESSED CEILING MOUNTING
The xture is suitable only for INDOOR RECESSED CEILING
application. Above ceiling access required.
To mount in an insulated or non-insulated ceiling - 9/16”or
15/16” exposed Flat Tee Grid Ceiling follow the steps below.
1. Firmly bend the pre-installed Grid Clips (4) up and out
as shown in Fig. 1.
2. Rotate and slide the Fixture as required to t through
the Tee-Grid Bar and place it as indicated by the
directional arrow as shown in Fig. 2. Secure the Fixture
to the Tee-Grid Bar.
3. Support wires are required by Installation Codes.
Support the Fixture to the building structure by
Support Wires (supplied by others) through the Grid
Clip Hole as shown in Fig. 3.
4. Make sure that the orientation of the Splice Box and
Access Plate faces an accessible tile to make electrical
splices.
5. Loosen Access Plate Screw and remove the Access
Plate. Knock out appropriate Conduit Knockouts
on the Access Plate to route input conduit. Use
appropriate conduit connectors as required by code
(Fig. 4.).
6. Connect wires as shown in wiring diagram. Push all
wires back into the Splice Box. Use appropriate UL
approved wire connectors as required by code to
complete wiring. Terminal Block accepts input power
wires of 16-18 AWG. If electrical supply wire is greater
than 16 AWG the installer must connect using a
16 AWG Pigtail (supplied). Be careful not to pinch wires.
WARNING: To prevent wiring damage or abrasion, do
not expose wiring to edges of sheet metal or other
sharp objects.
7. Replace Access Plate and tighten Access Plate Screw.
Support Wire
(supplied by
others)
Fig. 2
Fig. 1
Fig. 3
Fig. 4

EZPAN EDGELIT PANEL 2X2
INSTALLATION INSTRUCTIONS
Thank you for buying RAB lighting xtures. Our goal is to design the best quality products to get the job done right. We’d like to hear your comments.
Call the Marketing Department at 888-RAB-1000 or email: marketing@rabweb.com
TM
CLEANING & MAINTENANCE
CAUTION: Be sure xture temperature is cool enough to
touch. Do not clean or maintain while xture is energized.
1. Clean acrylic lens & xture with non-abrasive cleaning
solution.
2. Do not open xture to clean the LEDs. Do not touch the
LEDs.
TROUBLESHOOTING
1. Check that the line voltage at xture is correct. Refer to
wiring directions.
2. Is the xture grounded properly?
010V DIMMABLE WIRING
Universal voltage driver permits operation at 100V thru
277V, 50 or 60 Hz. 0-10V control wires must be rated for
300V minimum. Terminal block accepts input power wires
of 16-18 AWG.
1. Connect LINE supply lead to (L) marked on Terminal Block.
2. Connect COMMON supply lead to (N) marked on Terminal
Block.
3. Connect the GROUND wire to pre-installed Push-in
Connector.
4. Connect DIM+ lead to (DIM+) marked on Terminal Block.
5. Connect DIM- lead to (DIM-) marked on Terminal Block.
Easy Installation & Product Help
Tech Help Line
Call our experts 888 RAB-1000
©2016 RAB LIGHTING Inc.
No
rthvale, New Jersey 07647 USA
rabweb.com
Visit our website for product info
email
Answered promptly sales@rabweb.com
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation
or maintenance.
EZPAN EDGELIT PANEL 2X2 0616
For 12-14 AWG wire, insert supplied 16 AWG Pigtail wires into
Terminal Block.
1. Connect LINE supply lead to Black Pigtail with wire nut
supplied.
2. Connect COMMON supply lead to white Pigtail with wire
nut supplied.
3. Connect the GROUND wire to Green Pigtail with wire nut
supplied.
4. Connect DIM+ lead to (DIM+) marked on Terminal Block.
5. Connect DIM- lead to (DIM-) marked on Terminal Block.

Welcome
LCSENSE15/D10
Ceiling Sensor
© RAB Lighting, Inc
170 Ludlow Avenue Northvale, NJ 07647
Custom manufactured in China
1 (844) LIGHTCLOUD
1 (844) 544-4825
Lightcloud is a commercial
wireless lighting control system
& service. It’s powerful and
flexible, yet easy to use
and install. Learn more at
lightcloud.com
1 (844) LIGHTCLOUD
1 (844) 544-4825
WE ’RE HERE TO HELP:

Lightcloud is a wireless
lighting control service.
The Lightcloud Ceiling
Sensor is a remotely
configurable passive infrared
motion sensor that can
switch and dim both hard-
wired circuits and remote
circuits using Lightcloud
Controllers.
Hello
Product Features
Advanced PIR Sensing
Secure Cloud Control & Configuration
Retrofit-Friendly Local Control
Scheduling & Astronomical Clock
Power Monitoring
0-10V Dimming
Patent Pending

Contents
PART NUMBER
LCSENSE15/D10
INPUT
120-277VAC, 50/60Hz,
<1W (Standby) - 2W (Active)
MAXIMUM SWITCHED LOAD RATINGS
Electronic Ballast: 277VAC, 3300W
Magnetic Ballast: 277VAC, 1200W / 120VAC, 800W
Tungsten: 220VAC, 3000W
Dimming: 0-10V (Class2)
OPERATING TEMPERATURE
-20ºC to 40ºC
Specifications
OPERATING HUMIDITY
10% RH to 95% RH
Non-Condensing
OVERALL DIMENSIONS
4.91” Diameter, 1.61” Height
WIRELESS RANGE
Line-of-Sight: 1000 feet
Obstructions: 100 feet
Warranty is active as long as service plan is active.
Indoor Damp Location
Lightcloud Ceiling Sensor Instruction Manual
Wire Nuts
x 4
x 2
What You Need
Lightcloud Gateway
A Lightcloud installation requires
at least one Lightcloud Gateway to
manage your devices.
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
WE’RE HERE TO HELP:

Wiring SWITCHED NEUTRAL
The “Switched Neutral” white with red stripe wire is the
neutral line for the load being switched. This enables power
measurement. See the Power Measurement section under
“Functionality” for more information.
BLACK
WHITE/RED
0-10V
DIMMING
Panel
Load
BLACK / HOT
WHITE / NEUTRAL
WHITE
BLACK
RED
WHITE
PURPLE
GRAY
PURPLE
GRAY
Setup & Installation
1Find a suitable location
Use these guidelines when installing devices:
• If there is a clear line of sight between two Lightcloud devices,
they can be placed up to 1000 feet apart.
• If the two devices are separated by ordinary drywall construction,
try to keep them within 100 feet of each other.
• Brick, concrete and steel construction may require additional
Lightcloud devices to go around the obstruction.
!This product should only be installed by a qualified electrician
and in compliance with local and national electrical codes.
Lightcloud Gateway
<= 100 ft.
Add an additional Lightcloud
Device to extend network range
around corners B R IC K ,
CONC R E TE O R
M E TA L W AL L
D RY W AL L
OR SI MIL AR

Setup & Installation(cont’d)
DE VIC E ID s
3Labeling your device
For setup and maintenance, we provide two Lightcloud Device Tables with
the Gateway: one that you can attach to your panel and one to hand o to
a building manager. Attach the Device Identification stickers included with
each device to a row, then write in additional information, such as Zone
name, Panel/Circuit Number, and whether or not a zone uses dimming.
ZO NE NAM E PAN EL /
CI RCUIT #
INSTALL AT A JUNCTION BOX INDOOR/OUTDOOR
The Ceiling Sensor can control other Lightcloud devices, wirelessly.
If you don’t need to hard-wire a switched circuit to the Sensor,
no problem—just tie the white/red wire to neutral and cap o any
unused wires.
2Install your Lightcloud Ceiling Sensor
Sensor attached
attached to wired
junction box

Setup & Installation(cont’d)
4
5
Power up
Confirm device connectivity
Confirm Status Indicator is solid green. If it is not, make sure your
device is within range of another Lightcloud AC-powered device.
To add new devices to your Lightcloud network, call RAB at
STATUS
INDICATOR

Setup & Installation(cont’d)
6Place cover
Secure cover onto sensor by pushing up and twisting to the right (clockwise).
7Commission & Configure Your Devices
All Lightcloud products can be commissioned and configured by:
• Logging on to lightcloud.com
• Calling RAB at 1 (844) LIGHTCLOUD

Functionality
Overview
STATUS INDICATOR
POWER
INDICATOR
DEVICE
BUTTON
MOTION
INDICATOR
LIGHT
SENSOR
SENSOR
SIGNAL
INDICATOR
STATUS INDICATOR:
• Solid GREEN when connected to your Lightcloud network
• Blinking RED when not connected to a Lightcloud network. The device will
automatically continue trying to connect to a network that is in Setup Mode.
POWER INDICATOR:
Illuminated when powered. Blinking when indicated from the Lightcloud application.
SIGNAL INDICATOR:
After the Device Button has been pressed, this indicator illuminates when the
device receives a message and indicates the strength of the signal.
3 - Best Signal
2 - Acceptable Signal
1 - Unacceptable Signal
Consult the “Finding a Location” section for more information.
DEVICE BUTTON:
• Press once to highlight this device in the Lightcloud Application
(pressing once also enables display of the Signal Indicators)
• Press twice to toggle circuit on and o
• Press twice and hold to set dim level
• Press and hold for 10 seconds to remove this device from a Lightcloud network
MOTION INDICATOR:
Illuminates when motion is detected
SENSOR:
Passive-infrared motion sensor
Indice
Altri manuali RAB Portale
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente