Radionode RN400-T2CS Manuale utente

User Manual
IoT 4~20mA Signal Data Logger
RN400-T2CS
Keep this document nearby so that it may be referred to when needed.2021 | Rev. 1

02
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
CONTENTS
About this Manual 04
Intellectual Property Rights 04
Notational Conventions 04
Introduction 05
Key Features 05
Exterior 06
Accessories 07
Specifications 08
Installation 09
Terminal Block 10
Data Logger Installation 11
Connecting Terminal Block 13
4-20mA Signal Sensor 14
Operation 19
Viewing Channel Information 20
Viewing Device Information 21
Resetting Data Logger 22
Memory Card for Data Logging 23
Configuration 24
Device Information 26
Server 27
Measurement 28
Wi-Fi Network 30
Display 33
Commands 33
Memory Card Usage Configuration 34

03
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Checking Communication With Tapaculo 365 Server 35
RS-485 Modbus Communication 35
Tapaculo 365 36
Adding Devices from Your Smartphone 37
Adding Devices from Your Computer 40
Maintenance 43
Cleaning 43
Batteries 43
Firmware Update 44
Customer Service Information 45
Manufacturer Contact Information 45
Warranty 45
Limit of Liability 45
Certifications 46
HTTP Radionode Protocol V2 47
Check-in 47
Data-in 50
Order List 51
Data Logger 51
Accessories 52

04
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order List
About
this
Manual
This document contains instructions for usage and installation of
the RADIONODE®RN400-T2PS. Product specifications and certain
features herein may be subject to change without prior notice.
Figures used in this manual are for explanatory purposes only, and
may differ from your system depending on installation conditions.
Software screenshots may change after software updates.
Intellectual
Property
Rights
© 2021 DEKIST Co., Ltd.
All contents and figures herein are property of DEKIST Co., Ltd.
Reproduction or redistribution of all or part of this document in any
way is not permitted without prior consent from DEKIST.
Notational
Conventions
Failure to follow instructions marked with "Warning" may
result in slight injury to the user.
Failure to follow instructions marked with "Caution" may
result in equipment damage or malfunction.
Additional helpful information is marked with "Note".
About this Manual

05
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Introduction
The RADIONODE RN400-T2PS Data Logger periodically measures
temperature and RH, then sends measurement data to the Tapaculo®
365 server. The RN400-T2PS has a total of 4 I/O channels.
Channel 1 External 4~20mA
Analog Sensor Channel 2 External 4~20mA
Analog Sensor
Channel 3 External 4~20mA
Analog Sensor Channel 4 External 4~20mA
Analog Sensor
Key Features Key features of the RN400-T2PS include:
SW
POWER
ON/OFF
5BQBDVMPm
●Data Logger can be used with additional 4~20mA / 0~20mA
analog sensors.
●Use Wi-Fi connection to easily configure your Data Logger.
●Built-in buzzer that activates alarm when measurement is
outside the margin of error.
●Measurement data can be viewed remotely from Tapaculo 365
website. See Tapaculo 365 on page 36.
●Measurement data can be logged on a micro SD card.
Introduction

06
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Exterior
SW POWER
ON/OFF
2
3
4
1
5
❶ Display
❹ Power button
❷ Menu button
❺ Cable gland
❸ Display button
Power cables and cables of other devices, such as external sensors,
are connected via cable glands to the internal terminal block.
For instructions on how to use the buttons, see Operation on page
19.
Introduction

07
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Accessories All accessories, except for cable glands, are sold separately.
1.5 V Battery × 2 Cable Gland
3.6 V Battery
DC Adapter (12 V, 500 mA)
In the event of power failure, two C-type 1.5 V batteries or one 3.6 V
battery must be placed in the Data Logger. RADIONODE Data Logger
is designed to not operate without a battery, even when external
power is connected.
Only use Energizer®batteries. The Data Logger’s power
consumption varies significantly depending on operation
functions. Only Energizer batteries can keep performance
stable despite extreme battery usage fluctuations.
Introduction

08
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Specifications
SW
POWER
ON/OFF
165 mm
50 mm
100 mm
115 mm
RN400-T2PS Data Logger
External Sensor
Ch1 : 4 ~ 20mA Analog (accuracy: ±0.8 F.S.)
Ch2 : 4 ~ 20mA Analog (accuracy: ±0.8 F.S.)
Ch3 : 4 ~ 20mA Analog (accuracy: ±0.8 F.S.)
Ch4 : 4 ~ 20mA Analog (accuracy: ±0.8 F.S.)
Communication
2.4 GHz IEEE 802.11 b/g/n
WPA2-Enterprise
HTTP Get/Post
RS485 MODBUS RTU
Cable Gland PG-9
Water Resistance
Rating IP65 (IP67 is optional)
External DC power 5 - 30 V
Size 165 × 50 × 115mm
Operating conditions
-20 ~ 60 °C, 0 ~ 95% RH (non-condensed)
Introduction

09
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Installation
The following procedure will guide from the installation procedure to
the Tapaculo 365 registration process.
1. Install sensors or connect other devices to the Data Logger as
needed.
2. Connect power and insert the battery.
3. Use the virtual Wi-Fi router feature to configure the Data Logger.
See Configuration on page 24.
4. Now that the Data Logger has been installed, it must be registered
to Tapaculo 365. See Tapaculo 365 on page 36.
Depending on your installation circumstances and conditions, your
installation process may vary. For example, if you are installing
multiple Data Loggers, you might find it easier to:
1. Insert batteries into all Data Loggers before running.
2. Configure one Data Logger first.
3. Use a micro SD card to set up additional Data Loggers. For this
method, see Memory Card Usage Configuration on page 34.
4. Register the Data Loggers onto Tapaculo 365.
5. Finally, install the Data Loggers.

10
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Terminal
Block
Terminal Blocks can be found inside of a Data Logger, with other
components arranged as follows:
5 63 4 8
7
9
1 2 2
❶ Micro SD Card Slot
❹
FPC/FFC Connection
❼
RS485 Output
❷ Battery Holder
❺
USB for
Calibration
❽ DC Power
(5~30V)
❸
OLED Connection
❻ 4~20mA Input
❾ Select Battery
Type
Micro SD card is used to log measurement data. See Memory Card
for Data Logging on page 23.
The micro USB port is used for sensor calibration. As RN400 Series
sensors are shipped after calibration, no further calibration is
required. However, if the sensor malfunctions, contact DEKIST for
inspection.
For more information on the terminal block, see Connecting
Terminal Block on page 13.
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Radionode Registratore di dati