Installation and Operation Manual
IMPORTANT!
Before starting work the installer should carefully read this
Installation & Operation Manual, and make sure all instructions
contained therein are understood and observed.
- The Main zone digital programmer should be mounted, operated
and maintained by specially trained personnel only. Personnel in
the course of training are only allowed to handle the product under
the supervision of an experienced fitter. Subject to observation of
the above terms, the manufacture shall assume the liability for the
equipment as provided by legal stipulations.
- All instructions in this Installation & Operation manual should be
observed when working with the controller. Any other application
shall not comply with the regulations. The manufacturer shall not
be liable in case of incompetent use of the control. Any
modifications and amendments are not allowed for safety reasons.
The maintenance may be performed by service shops approved by
the manufacturer only.
- The functionality of the controller depends on the model and
equipment. This installation leaflet is part of the product and has to
be obtained.
APPLICATION
- The Main zone digital programmer is developed to control and
manage all installations of water floor heating and cooling
equipped with our UFH range thermostat. The temperature in each
room is managed the control of actuators mounting on the
manifold.
- The controller is normally used in conjunction with a complete
connecting box “UFH- MASTER” with or without Heating & Cooling
function to connect all electrical & hydraulic components of the
installation like a circulation pump, actuators...
- The controllers have been designed for use in residential rooms,
office spaces and industrial facilities.
Verify that the installation complies with existing regulations before
operation to ensure proper use of the installation.
SAFETY INSTRUCTIONS
Before starting work disconnect power supply!
- All installation and wiring work related to the controller must be
carried out only when de-energized. The appliance should be
connected and commissioned by qualified personnel only. Make
sure to adhere to valid safety regulations.
- The connecting boxes are neither splash- nor drip-proof.
Therefore, they must be mounted at a dry place.
- Do not interchange the connections of the thermostats and the
230V connections under any circumstances! Interchanging these
connections may result in life endangering electrical hazards or
the destruction of the appliance and the connected sensors and
other appliances.

4
Table of contents
First Installation..........................................................61
1.1 Power supply.............................................................. 6
1.2 First adjustments........................................................ 6
Presentation, Main display.........................................82Settings menu ............................................................93
3.1 Thermostat submenu (For main zone only).............. 10
3.2 Zone submenu ......................................................... 11
Zone Settings---------------------------------------------------123.2.1 Working mode--------------------------------------------------123.2.2
3.3 Display submenu...................................................... 19
Screen Lock-----------------------------------------------------193.3.1 Screen saver----------------------------------------------------193.3.2 Clean Screen---------------------------------------------------203.3.3 Colour ------------------------------------------------------------203.3.4
3.4 Date & Time submenu.............................................. 20
3.5 Holiday submenu...................................................... 21
3.6 On/Off submenu....................................................... 23
3.7 Statistics submenu................................................... 23
3.8 Language submenu.................................................. 24
3.9 Main settings Submenu............................................ 24
Installation –Regulation sensor----------------------------253.9.1 Installation –Calibration sensor----------------------------263.9.2 Installation –Regulation type -------------------------------273.9.3 Installation –Pump Exercise--------------------------------273.9.4 Installation –Installation type -------------------------------283.9.5 °C/°F--------------------------------------------------------------293.9.6 Factory settings ------------------------------------------------293.9.7
3.10 Installation –RF installation ..................................... 30
3.11 Heat & Cool Submenu.............................................. 32
3.12 Outside Sensor Submenu........................................ 33
Special Function.......................................................344
4.1 Software version:...................................................... 34
4.2 Information screen:................................................... 34
Divers.......................................................................355
5.1 Memory safe ............................................................ 35
5.2 Corresponding value for sensors (NTC 10K) ........... 35
Technical characteristics..........................................366

5
Main characteristics
Flush Mounting version, standard fixing with 60mm axes.
Full Colour TFT display, with touch screen function.
Convivial interface with coloured logo.
Available for Heating & cooling installations (with reversible heat
pump).
Rename function for zones.
Several languages available.
Graphic view for program.
Thermostat function with possibility to regulate on:
- Air sensor only.
- Floor sensor only.
- Air & Floor combined with different possibilities.
Temporary override function (2H).
Holiday function.
Sensors Auto checks (Short circuit and breaks).
Permanent memory storage.
Available options:
Outside sensor for weather compensation.
Humidity sensor for cooling application.
GSM unit for external access and supervising.
To prevent non desired change due to touch screen function, some
menu will not be easily accessible after 1 hour powered, and then
press a long time on the desired button to have again access.

6
First Installation1
1.1 Power supply
When connecting the Main zone programmer for the first time,
several parameters need to be adjusted. (Clock, language…)
Your unit must be charged for at least 24 hours to reach
maximum capacity to back up time.
1.2 First adjustments
a) Language
Follow the rules to access the language menu,
One short
press to skip
Software
version
1)
2)
3)

7
Once the language menu is opened, choose your language by
using the left or right arrow on each side of the flag.
Once you have made your choice, press on the home button to
come back to the previous screen and go to the next adjustment.
b) Date & Time
Now you are invited to adjust the time and date. To make this
adjust the value underlined in black with (+) & (-) buttons.
Use the arrow buttons to jump to the next values.
Press on the setting button to access the advanced options.
2)
3)
1)

8
Presentation, Main display2
*
The logo will be in movement to show water circulation in the zone.
The logo could be different following the brand of your device.
Quick access description:
- Press on the sensor logo to view the others sensors connected to
your unit and choose the value which will be displayed on the main
screen by pressing on it. (Highlighted in green)
You must connect:
A Floor sensor to view the temperature of floor.
A RH humidity sensor to view residual humidity.
- Press on the temperature on the middle of the screen to have a
quick access to the current setting and working mode.
Working
mode. *
Zone menu
Setting
menu
Actual
working
mode
Sensor use
for
regulation
Room
temperature
Information symbol
See part 5.2

9
From this screen you will have the possibilities to adjust:
- The setting temperature of the current working mode by using
the buttons arrow (Up and Down).
- The working mode by pressing on the Working mode logo.
Settings menu3 1st Page 2nd page
3rd Page 4th page
The menu can be organized differently following the device
installed.

10
3.1 Thermostat submenu (For main zone only)
On this submenu you can see and adjust the settings temperature
for the main zone (zone managed by this unit).
Comfort setting
Change the set point for Comfort temperature by using the arrows
buttons (Up)or (Down).
This setting is also used in “Auto” mode.
Valid or cancel your adjustment with the corresponding button.
Reduced setting
Change the set point for Reduced temperature by using the arrows
buttons (Up)or (Down).
This setting is also used in “Auto” mode.
Humidity level
(Only available with humidity sensor connected)
The Humidity level is used only in cooling mode to prevent the
house of floor condensation.
If humidity is detected the system will stop the cooling function in
the house and start up the humidity drier connected to the RF H&C
Master.
The activation of this function will be showed on main screen by:
- A yellow information logo .
- A blinking Cooling logo.
One short
press to
adjust the
set point.