SECTION 4 GENERAL REQUIREMENTS
4.0
SAFETY
Gas Safety (Installation and Use).
Regulations, 1994 and amended 2000.
It is law that all gas appliances are installed
and serviced by a CORGI registered in-
staller in accordance with the above regula-
tions and these installation instructions. All
CORGI registered installers carry a CORGI
I.D. card and have a registration number.
Both should be recorded in your boiler log
book. You can check your installer by calling
CORGI direct on: 01256 732300. Failure to
install appliances correctly could lead to
prosecution. It is in your own interest, and
that of safety, to ensure the law is complied
with. Check the boiler and flue is the correct
type for installation.
The installation of the boiler MUST be in ac-
cordance with the latest I.E.E. (BS 7671)
Wiring Regulations, local building regula-
tions, bye-laws of the local water authority,
the building regulations and the Building
Standards (Scotland) and any relevant re-
quirements of the local authority.
4.1
GENERAL INFORMATION
Both the user and the manufacturer rely heavi-
ly on the installer, whose job it is to install the
combination boiler and connect it to a correctly
designed heating system. Acquaint yourself
with the British Standards concerning installa-
tion requirements. If you need advice on any
points your Ravenheat Technical Services Of-
fice would be pleased to help. It is recommend-
ed that tools suitable for brass fittings are used,
and have a capability to accomodate hexagon
sizes up to 50 mms.
CODES OF PRACTICE/Ref: Documents
Detailed recommendations are contained in
the following British Standard Codes of
Practice:
BS. 6891
Low pressure installation pipes.
BS. 6798
Installation of gas fired hot wa-
ter boilers of rated input not ex-
ceeding 60 kW.
BS. 5449
Forced circulation hot water
systems.
BS. 5546
Installation of gas hot water
supplies domestic purposes
(2nd Family Gases).
BS. 544O:1 Flues (for gas appliances of rated
input not exceeding 60 kW).
BS. 5440:2 Ventilation (for gas appliances of
rated input not exceeding 60 kW).
DD 189:1990 Discharge of condensate
Health & Safety Document No. 635
The Electricity at Work Regulations, 1989.
The manufacturer’s notes must NOT be tak-
en, in any way, as overriding statutory oblig-
ations
IMPORTANT. These appliances are CE cer-
tificated for safety and performance. It is,
therefore, important that no external control
devices e.g. flue dampers, economisers
etc., are directly connected to this appliance
unless covered by these Installation and
Service Instructions or as otherwise recom-
mended by Ravenheat in writing. If in doubt
please enquire.
Any direct connection of a control device not
approved by Ravenheat could invalidate the
certification and the normal appliance war-
ranty. It could also infringe the Gas Safety
regulations and the above regulations.
NOTE: The Ravenheat CSI combination
boiler has been tested and examined by BG,
and is certified to comply with PrEN 483 and
BS EN 625.
Manufacturers instructions must NOT be
taken in any way as overriding statutory
obligations.
If in doubt on any point please consult
Ravenheat Manufacturing Ltd.
4.2
LOCATION OF BOILER
4.2.1
Siting of Ravenheat CSI 85 Combi Boiler
must be as follows. The position of installa-
tion should be within the building, unless
otherwise protected by suitable enclosure.
Adequate space for installation, servicing
and air circulation around boiler must be al-
lowed for.
The Ravenheat CSI 85 Combi Boiler must
be fitted on a flat and vertical wall capable of
adequately supporting the weight of the boil-
er and any ancillary equipment.
The appliance may be installed on a com-
bustible wall subject to the requirements of
the Local Authority and Building Regula-
tions.
LPG versions of this appliance shall not
be installed in cellars or basements.
4.3
CLEARANCES AROUND THE APPLIANCE
4.3.1
The following minimum free spaces, re-
quired for installation inspection and servic-
ing, must be left around the boiler
18 inches (450 mm) in front
5 inches (125 mm) above
6 inches (150 mm) below
0.2 inches (5 mm) on each side
1 inch (25 mm) in front when installed in a
cupboard.