RDM EC6000i Gen2 Manuale utente

EC6000iGen2 and EC7000iSeries
Installation Guide

This manual, the EC6000i Gen2 and EC7000i Series Installation Guide, is intended for all
units belonging to the EC6000i Gen2 and EC7000i family of products.
EC6000i Gen2 is a registered trademark of RDM Corporation. EC7000i, ITMS, RDM, and the RDM logo
are all trademarks of RDM Corporation. All other brand names and trademarks appearing in this guide are
the property of their respective holders.
Copyright© RDM Corporation, 2005
All rights reserved. No part of this document may be reproduced in any form
without the written consent of RDM Corporation.
Part Number: 302665
Revision Number: A

1
Contents
Compliance Statements ..........................................................2
Introduction..............................................................................3
Requirements..........................................................................4
Setting Up the EC6000i Gen2 or EC7000i ..............................5
Maintaining the EC6000i Gen2 or EC7000i...........................16
Troubleshooting.....................................................................18
Specifications ........................................................................21
Warranty Information.............................................................24

2
Compliance Statements
FCC Compliance Statement NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his or
her own expense.
If an internal modem is present: RDM’s EC6000i Gen2 and EC7000i are designed to be used on standard device telephone lines. It connects
to the telephone line by means of a standard jack (USOC RJ-11C). An FCC compliant telephone cord with modular plug is provided to connect
the equipment to the telephone network or premises wiring using a Part 68 compliant compatible jack. Connection to telephone company
provided coin service is prohibited. Connection to party line service is subject to state tariffs.
Telephone company procedures: The goal of the telephone company is to provide you with the best service it can. In order to do this, it may
occasionally be necessary for them to make changes in their equipment, operations or procedures. If these changes might affect your services or
the operation of your equipment, the telephone company will give you notice, in writing, to allow you to make any changes necessary to
maintain uninterrupted service. In certain circumstances, it may be necessary for the telephone company to request information from you
concerning the equipment that you have connected to your telephone line (FCC registration number and ringer equivalence number –REN. See
underside of the EC6000i Gen2 or EC7000i unit). In order to assure proper service from the telephone company, the sum of all REN’s on each
telephone line should be five or less. In some cases, a sum of five REN’s may not be useable on a given line.
If problems arise: If any of your telephone equipment is not operating properly, you should immediately remove it from your telephone line,
as it may cause harm in the telephone network. If the telephone company notes a problem, they may temporarily discontinue service. When
practical, they will notify you in advance of this disconnection. If advance notice is not feasible, you will be notified as soon as possible. When
you are notified, you will be given the opportunity to correct the problem and informed of your right to file a complaint with the FCC. Contact
your telephone company if you have any questions about your phone line. In the event repairs are ever needed to the EC6000i Gen2 or
EC7000i, they should be performed by RDM Corporation or an authorized representative of RDM Corporation.
For information contact: RDM Corporation, 608 Weber Street North, Waterloo, Ontario, Canada N2V 1K4

3
Introduction
The EC6000i Gen2 and the EC7000i are cost effective, feature rich, imaging solutions. Utilizing RDM's
industry leading progressive MICR method and imaging technology, the EC6000i Gen2 and the EC7000i
are ideal for Check Electronification, Check Cashing, and Walk-in Bill Payment applications.

4
Requirements
§The EC6000i Gen2 and the EC7000i units are for indoor use only. Keep the EC6000i Gen2 and the
EC7000i dry and avoid areas of high humidity.
§The EC7000i requires a higher current power supply (RDM P/N# 302671). The EC6000i Gen2 can use
its supplied power supply or the higher current power supply. See Specifications on page 21 for
power supply details.
§Do not remove any cabinetry other than the areas specified in this guide; removing cabinetry other
than the areas specified in this guide will void the warranty.
Recommendations
§This unit may be installed and programmed by a distributor (reseller) other than the original
manufacturer. Record all distributor contact information for future reference.
§Save the original box and packing material. Re-use them if the unit must be shipped to a new location.
§Position the unit so that the operator has easy access to the check path and a clear view of the LED.
Do not put the unit close to a heat source, in direct sunlight, or close to any device that can emit
electromagnetic interference such as a computer monitor or power adapter. Do not use the unit near
water, including a sink, swimming pool, or damp basement.

5
Setting Up the EC6000i Gen2 or EC7000i
To set up the EC6000i Gen2 or EC7000i, follow steps A –F.
A. Choose a Location
Locate your scanner in a place that:
§has a flat surface, such as a countertop or table,
§is convenient for the scanner operator,
§offers adequate ventilation and protection from
elements such as heat, dust, oil or moisture, and
§is close to a telephone line or network connection
(depending on your unit) and power connections.
B. Unpack the Shipping Box
1. Open the top of the box.
2. Remove and unwrap the items.
3. Save the box and wrapping for future use.
NOTE:
Before unpacking the box,
examine it fo
r damage received during
shipping. If the scanner, or any
component, appears damaged, do not
use it. File a claim with the shipping
company and contact your distributor.
Your EC6000i Gen2 or EC7000i
product package includes the following:
§The EC6000i Gen2 or EC7000i
scanner
§Power adapter
§Telephone line (optional with
modem)
§Franking Acknowledgement
Printer Cartridge (optional)

6
C. Inspect the Unit’s Features
The EC6000i Gen2 and the EC7000i are provided in two models. Model A below has an integrated
Magnetic Stripe Reader (MSR). Model B below does not include an MSR. Scanner Model A will be
graphically represented throughout this manual for consistency. All other features of the EC6000i Gen2 and
EC7000i are available as standard or optional on either model.
Check
Insertion
Slot
Terminal
Status LED
(Light)
Magnetic
Stripe Reader
Check Insertion Slot
Terminal Status LED
(Light)
Model A
Model B

7
Inside Components:
Cover Latch
Outside Cover in raised position
Image Frame in raised position
Image Sensor
Document Feed Plate comes out to reveal
the optional Franking Acknowledgement
Printer Assembly (EC7000i shown)
Document Sensors

8
Connection Ports:
RDM’s EC6000i Gen2 and EC7000i can be installed in different configurations. These configurations are set and
programmed by the distributor (reseller) to suit your unique needs.
Follow instructions provided by your distributor (reseller).
Power: Red. Connect the power adaptor to this port.
USB: Orange. Use this port to connect to a PC.
AUX: Yellow. Use this port to connect optional
peripheral devices such as a pass through
printer
COM: Green. Use this port to connect to a PC or
terminal
TEL: Purple. This port offers an optional modem,
to be connected to a telephone line. Some
scanners may not contain a TEL Port.
Power
USB
AUX
COM
TEL
Questo manuale è adatto per i seguenti modelli