Real Time Automation 460EAV Manuale utente

460EAV Gateway
User Guide

Trademarks
CompactLogix, ControlLogix, & PLC-5 are registered trademarks of Rockwell Automation, Inc.
EtherNet/IP is a trademark of the Open DeviceNet Vendors Association (ODVA).
MicroLogix, RSLogix 500, and SLC are trademarks of Rockwell Automation, Inc.
Microsoft, Windows, and Internet Explorer are registered trademarks of Microsoft Corporation.
All other trademarks and registered trademarks are the property of their holders.
Limited Warranty
Real Time Automation, Inc. warrants that this product is free from defects and functions properly.
EXCEPT AS SPECIFICALLY SET FORTH ABOVE, REAL TIME AUTOMATION, INC. DIS-
CLAIMS ALL OTHER WARRANTIES, BOTH EXPRESSED AND IMPLIED, INCLUDING BUT
NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR APPLICATION. THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS. YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE.
The examples and diagrams in this manual are included solely for illustrative purposes. Because of the
many variables and requirements associated with any particular application, Real Time Automation,
Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams. Ex-
cept as specifically set forth above, Real Time Automation and its distributors and dealers will in no
event be liable for any damages whatsoever, either direct or indirect, including but not limited to loss
of business profits, income, or use of data. Some states do not allow exclusion or limitation of inciden-
tal or consequential damages; therefore, the limitations set forth in this agreement may not apply to
you.
No patent liability is assumed by Real Time Automation with respect to use of information, circuits,
equipment, or software described in this manual.
Government End-Users
If this software is acquired by or on behalf of a unit or agency of the United States Government, this
provision applies: The software (a) was developed at private expense, is existing computer software,
and was not developed with government funds; (b) is a trade secret of Real Time Automation, Inc. for
all purposes of the Freedom of Information Act; (c) is “restricted computer software” submitted with
restricted rights in accordance with subparagraphs (a) through (d) of the Commercial “Computer Soft-
ware-Restricted Rights” clause at 52.227-19 and its successors; (d) in all respects is proprietary data
belonging solely to Real Time Automation, Inc.; (e) is unpublished and all rights are reserved under
copyright laws of the United States. For units of the Department of Defense (DoD), this software is
licensed only with “Restricted Rights”: as that term is defined in the DoD Supplement of the Federal
Acquisition Regulation 52.227-7013 (c) (1) (ii), rights in Technical Data and Computer Software and
its successors, and: Use, duplication, or disclosures is subject to restrictions as set forth in subdivision
(c) (1) (ii) of the Rights in Technical Data and Computer Software clause at 52.227-7013. If this soft-
ware was acquired under GSA schedule, the U.S. Government has agreed to refrain from changing or
removing any insignia or lettering from the Software or documentation that is provided or from pro-
ducing copies of the manual or media. Real Time Automation, Inc., 150 S. Sunnyslope Rd. Suite 130,
Brookfield, WI 53005.
© 2008 Real Time Automation, Inc. All rights reserved.

Real Time Automation, Inc. 1 1-800-249-1612
460 Gateway Device Line 460EAV
Overview
The 460EAV Gateway device seamlessly connects up to ten Altivar Drives to an EtherNet/IP client such as
a ControlLogix® PLC. By following this guide, you will be able to configure the 460EAV Gateway for
basic operation. You will set the device’s network settings and parameters to the proper configuration for
initial operation and physically place the device in the network.
For further customization and advanced use feel free to consult the provided 460 User Manual. In
addition, Real Time Automation would be happy to provide support to help you utilize the device.

Real Time Automation, Inc. 2 1-800-249-1612
460 Gateway Device Line 460EAV
2
Required Tools and Data
You will need the following tools:
♦ The460EAVGateway
♦ TheprovidedCD‐ROM
♦ AWorkingPC(Windowsbased)
♦ TheSuppliedEthernetCrossoverCable
♦ A7‐30VDCpowersource(T‐strip)
You will also need to verify the following Modbus RTU Slave Settings:
♦ ConnectorType
♦ Mode(RS485orRS422)
♦ BaudRate
♦ Parity
♦ DataBits
♦ StopBits
♦ StopBits

Real Time Automation, Inc. 3 1-800-249-1612
460 Gateway Device Line 460EAV
Port Connections
The factory default port settings on the 460EAV gateway are for Port 0 (T-strip) to be set to RS485 and
Power while Port 1 (DB-9) is set to RS232 by default.
If these default port settings are incompatible with your equipment they can be configured differently. For
assistance changing port configurations contact our customer support department. For specific jumper and
pin settings refer to the end of this manual, appendix A.

Real Time Automation, Inc. 4 1-800-249-1612
460 Gateway Device Line 460EAV
Accessing the Main Page
The network settings must be configured to access the gateway’s Main Page. The Main Page allows the
user to edit the parameters which are required to connect the desired devices. The following steps will
connect the gateway to the network properly.
1) Connect the 7-30 VDC power source to the device via the T-strip.
2) Using the crossover cable connect the device to the PC. (If you are connecting through a hub or
switch use a standard Ethernet cable.)
3) Insert the provided CD-ROM.
4) Run the IPSetup program from the CD-ROM.
5) Configure the IP Address of the unit for your
subnet. (Ex: If your workstation IP address is
192.168.0.1 an acceptable IP Address for the
gateway would be 192.168.0.100.)
6) Click Set.
NOTE
Browser configuration is only Internet
Explorer compatible. The use of
FireFox is not supported.
Default IP address is 192.168.0.100

Real Time Automation, Inc. 5 1-800-249-1612
460 Gateway Device Line 460EAV
5
Error: Main Page Does Not Launch
If the main page does not launch the IP Address is most likely incorrect. Correct the IP Address and try
again. If you do not know the IP address use the following procedure:
1) Open an MS-DOS Command Prompt.
2) Type ipconfig and press enter.
3) Note the IP Address. (The previous example was 192.168.0.1)
4) To test the communication between the PC and the uni, type ping (###.###.#.###) in the prompt
and press enter. The (###.###.#.###) is a placeholder for the IP Address you used in step 5 of
network configuration which was192.168.0.100. If the device is connected to the network the ping
will show a response. If you get no response check the crossover cable and any other network
devices.

Real Time Automation, Inc. 6 1-800-249-1612
460 Gateway Device Line 460EAV
Modbus RTU Master Settings
Now that the device is on the network you will configure the device settings. As a reminder you will need
to know the connector type, mode, baud rate, parity, data bits and stop bit settings of your Modbus RTU
slave device in order to complete device configuration.
1) If you would like to change the device description, click Edit in the Description row on the main
page. Otherwise, skip to step 4.
2) Type the desired description into the text box.
3) Click Save.
4) In the Selected Communication Modules row, click Edit.
5) In the Modbus RTU Master row, click Edit.
6) Verify that the Enabled box is checked.

Real Time Automation, Inc. 7 1-800-249-1612
460 Gateway Device Line 460EAV
7) The Response Timeout and Delay Between Polls default to 500 and 50 milliseconds respectively. To
customize the values enter the new time in milliseconds.
8) Select the appropriate settings in the Connector, Mode, Baud, Parity, Data and Stop fields. The
settings should match your Modbus RTU slave device.
9) Click Save to save your configuration.
10) Click Return to Main Page.
If your data is not flowing correctly after installing the device on the
network, check that the settings selected match the settings of your Modbus
Slave device. Incorrect settings will skew operation.

Real Time Automation, Inc. 8 1-800-249-1612
460 Gateway Device Line 460EAV
Modbus TCP Server and Ethernet/IP Server Settings
The Modbus TCP Server and Ethernet/IP Server have no configurable settings.
Indice
Altri manuali Real Time Automation Portale

Real Time Automation
Real Time Automation 460SCQT-N2E Scheda tecnica

Real Time Automation
Real Time Automation 460BMSAWS-NNA1 Scheda tecnica

Real Time Automation
Real Time Automation 460BCQT-NNA4 Scheda tecnica

Real Time Automation
Real Time Automation 460BMQT-NNA4 Scheda tecnica

Real Time Automation
Real Time Automation 460BMSAWS-N2E Scheda tecnica
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente