Red Arrow PC10A Manuale utente

PRODUCT: PHOTOCELL
PRODUCT CODES: PC10A & PC10AH
BOX CONTENTS -
PC10A - PHOTOCELL KIT
PC10AH - PHOTOCELL HEAD
SPECIFICATION
Dimensions: PC10A - L: 130 x Ø:80mm
PC10AH - L: 64 x Ø:80mm
Material: PC
Working
Temperature: -40° - 70°C
Included: Photodiode Sensor
Additional
Information Max load 1000W LED or Resistive
SAFETY WARNING
• The installation should be carried out
by a qualified electrician in compliance
with the current edition of the IEE
Wiring Regulations.
• Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk, the
level of risk and the precautions
required to control the risk
• Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned off before
installation or any maintenance.
• Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
• Long-term use and voltage fluctuations
can reduce the life span of the fitting.
• If the fitting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
• Follow the provided installation
instructions, using the fixings supplied
or recommended.
• Keep out of reach of children.
IP65 1
YR
GUARANTEE
INSTALLATION INSTRUCTIONS
T: 0800 195 0006
Red Arrow Electrical Distribution
Cortonwood Drive, Brampton,
Barnsley, S73 0UF
redarrowelectrical.co.uk
PAGE 1 (FRONT PAGE)
G U A R A N T E E
This product is guaranteed for a period of 1 year from the date of
purchase. The guarantee is invalid in the case of improper use, tampering,
removal of the Q.C. date label, installation in an improper working
environment or installation not according to the current edition of the
I.E.E. Wiring Regulations (BS7671).
The guarantee is also invalidated if the luminaire has been insulation
tested. Should this product fail during the guarantee period it will be
replaced free of charge, subject to correct installation and return of the
faulty unit. We do not accept responsibility for any installation costs
associated with the replacement of this product. Your statutory rights
are not affected. We reserve the right to alter specifications without prior
notice.
M A I N T E N A N C E
• This fitting will require routine cleaning if used in adverse (dust, paint,
welding, oils etc) environments. Do not use solvents, aggressive detergents
or abrasives.
• When this fitting comes to the end of it’s life or you choose to replace it,
please do not dispose of it with your normal household waste. Please
recycle where the facilities exist, check with your local authority for suitable
options.
PAGE 2 (TWO - INSIDE DPS)
240V

PAGE 1 (FRONT PAGE)
T: 0800 195 0006
Red Arrow Electrical Distribution
Cortonwood Drive, Brampton,
Barnsley, S73 0UF
INSTALLATION INSTRUCTIONS
PRODUCT: PHOTOCELL
PRODUCT CODES: PC10A & PC10AH
redarrowelectrical.co.uk
1. CAREFULLY CHOOSE THE CORRECT POSITION TO INSTALL THE PHOTOCELL KIT CONSIDERING THE FOLLOWING GUIDE LINES:
• WHERE POSSIBLE THERE SHOULD BE A CLEAR VIEW OF THE SKY, ALLOWING SUFFICIENT DISTANCE WHEN MOUNTING
UNDER EVES.
•FOR OPTIMUM PERFORMANCE THE POSITION CHOSEN SHOULD HAVE A CLEAR VIEW OF NORTH.
•BE AWAY FROM VIEW OF ANY ARTIFICIAL LIGHT SOURCE.
•BE AWAY FROM VIEW OF THE LIGHT SOURCE THE UNIT IS TO CONTROL.
2. SECURELY FIX THE BASE HOLDER TO A VERTICAL WALL SO THAT THE HEAD WILL BE FACING UP WHEN FITTED.
3. FIT THE GASKET INTO THE BASE HOLDER FOAM SIDE UP.
4. ENTER THE SUPPLY & LOAD CABLE INTO THE BASE THROUGH THE HOLE IN THE BOTTOM OF THE BASE ENSURING THAT A
CABLE GLAND GROMMET OR SEALING COMPOUND IS USED TO MAINTAIN THE IP RATING OF THE UNIT.
5. TERMINATE THE CABLE INTO THE NEMA SOCKET OBSERVING THE CORRECT CONNECTIONS;
“LI” = LIVE (SUPPLY IN)
“LO” = LOAD (SUPPLY OUT)
“N” = NEUTRAL (THE NEUTRAL TO THE LOAD DOES NOT NEED TO PASS THROUGH THE UNIT AND CAN BE TAKEN DIRECTLY).
6. PLACE THE NEMA SOCKET INTO THE BASE HOLDER WITH THE ARROW PRINTED ON THE SOCKET POINTING TOWARDS NORTH.
IF NORTH IS LOCATED BEHIND THE UNIT TOWARDS THE MOUNTING SURFACE THEN THE ARROW SHOULD BE ALIGNED
POINTING IN THE DIRECTION OF BEST NATURAL LIGHT.
7. THE BASE HOLDER HAS 2 LOCATING PINS FOR THE NEMA SOCKET TO FIT ONTO, THE NEMA SOCKET SHOULD THEN BE
SECURED USING THE 2 COUNTER SUNK SELF TAPPING SCREWS PROVIDED.
8. ALIGN THE LARGEST OF THE 3 BRASS FEET MARKED ‘NEUTRAL’ ON THE PHOTOCELL HEAD WITH THE LARGEST SLOT IN THE
NEMA SOCKET, PUSH THE PHOTOCELL HEAD INTO THE NEMA SOCKET AND GENTLY TURN CLOCKWISE TO LOCK INTO PLACE.
INSTALLATION INSTRUCTIONS -
PAGE 2 (TWO - INSIDE DPS)
• THE PHOTOCELL ALWAYS POWERS UP IN THE “ON” POSITION, IF IN BRIGHT DAYLIGHT IT WILL SWITCH OFF WITHIN 2 MINUTES.
• TO TEST FOR CORRECT OPERATION COVER THE PHOTOCELL WITH THE PACKING BOX, AFTER A SHORT DELAY, 15-120 SECONDS,
THE PHOTOCELL WILL OPERATE AND POWER WILL BE APPLIED TO THE LOAD. IF TESTED IN BRIGHT DAYLIGHT AFTER A SIMILAR
DELAY THE PHOTOCELL WILL TURN OFF THE POWER TO THE LOAD WHEN THE PACKAGING BOX IS REMOVED.
• THE LOAD STAYS ON:
THE PHOTOCELL IS IN A SHADY OR DARK POSITION.
THE NEUTRAL IS NOT CONNECTED.
• THE LOAD IS FLASHING, STROBING OR SWITCHING ON AND OFF REPEATEDLY THROUGH HOURS OF DARKNESS:
THE PHOTOCELL IS TOO CLOSE TO THE LIGHT SOURCE IT IS CONTROLLING.
“LI” & “LO” ARE REVERSED.
COMMON PROBLEMS -
OPERATION & TESTING -
INS/ACCESSORIES/0001/PC10/V2
Questo manuale è adatto per i seguenti modelli
1
Indice