Reed Instruments R2170 Manuale utente

www.REEDInstruments.com
Thermal
Imaging
Camera
Instruction
Manual
R2170
White background
Transparentbackground
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
G
A
R
A
N
T
I
E
G
A
R
A
N
T
I
E
White
G
A
R
A
N
T
I
E
G
A
R
A
N
T
I
E
2YEAR2ANS
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
2YEAR
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
W
A
R
R
A
N
T
Y
2YEAR
G
A
R
A
N
T
I
E
G
A
R
A
N
T
I
E
2ANS
www. .com information@itm.com1.800.561.8187

Table of Contents
Introduction ................................................................................................ 3
Product Quality........................................................................................... 3
Safety ......................................................................................................... 4
Features...................................................................................................... 5
Included...................................................................................................... 5
Specications..........................................................................................6-7
Instrument Description ............................................................................... 8
Display Description .................................................................................... 9
Power ON/OFF ...................................................................................... 9
Emissivity.................................................................................................. 10
Software Installation................................................................................. 11
Operating Instructions.........................................................................11-17
Main Menu ......................................................................................11-14
Enabling/Disabling Center Point & High/Low
Temperature Spot ............................................................................ 11
Image Mode Selection..................................................................... 12
Color Palette Selection .................................................................... 12
Image Measurement Tools............................................................... 13
Isotherm and Temperature Span Settings...................................13-14
Turning the LED Flashlight ON/OFF..................................................... 14
Enabling/Disabling Digital Zoom.......................................................... 14
Advanced Settings Menu................................................................15-17
Changing Camera Mode .................................................................. 15
Setting the Unit of Measure.............................................................. 15
Setting Image Parameters (Emissivity and Object Distance)............ 15
Setting High/Low Alarms.................................................................. 15
Setting the Language ....................................................................... 16
Setting the Date and Time Format ................................................... 16
continued...
www. .com information@itm.com1.800.561.8187

Changing USB Mode ....................................................................... 16
Adjusting Display Brightness............................................................ 16
Auto Power Off................................................................................. 16
Factory Reset ................................................................................... 16
Format SD Card ............................................................................... 17
Saving, Viewing & Deleting Images .................................................. 17
Charging the Battery ................................................................................ 17
Applications.............................................................................................. 18
Accessories and Replacement Parts ....................................................... 18
Product Care ............................................................................................ 18
Product Warranty ..................................................................................... 19
Product Disposal and Recycling .............................................................. 19
Product Support....................................................................................... 19
Introduction
Thank you for purchasing your REED R2170 Thermal Imaging Camera.
Please read the following instructions carefully before using your instrument.
By following the steps outlined in this manual your meter will provide years
of reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet the stated product
specications. If a certicate of calibration is required please contact the
nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
www. .com information@itm.com1.800.561.8187

Safety
• Never attempt to repair or modify your instrument. Dismantling
your product may cause damage that will not be covered under the
manufacturer's warranty. Servicing should only be provided by an
authorized service center.
• Do not point the thermal imager (with or without the lens cover) at
intensive energy sources as this can damage the thermal imager.
• Do not use the thermal imager in a temperature higher than 122°F (50°C).
• Always charge the battery between 32 to 122°F (0 to 50°C).
• Clean the case with a damp cloth and a diluted soap solution.
• Do not use abrasives, isopropyl alcohol, or solvents to clean the
instrument, lens or screen.
• Do not clean the infrared lens too vigorously, this can damage the
anti-reective coating.
• Store the thermal imager in cool and dry environment.
• Please use the correct emissivity to obtain accurate temperature
measurements.
• To ensure accuracy, please let the instrument warm up for 10 minutes
before taking a measurement if it has not been used for a long time.
• When being charged, the internal temperature of the product will rise, which
will lead to inaccurate temperature measurement, it is not recommended
to take measurements during or right after charging the instrument.
www. .com information@itm.com1.800.561.8187

Features
• 320 x 240 infrared resolution (76,800 pixels)
• 3.5" color IPS Display
• Built-in dual LED ashlight
• Choice of 7 color palettes
• Intuitive on-screen measurement tools
• 4 image modes (Thermal, Visual Image, Picture-in-Picture,
Fusion (Thermal Blending))
• High and Low temperature spot and alarm indicators
• IP54 and 6.5' (2m) drop tested
• 4x digital zoom
• Rechargeable Li-ion battery
• Tripod mountable for continuous long-term monitoring
• View, analyze stored data and generate reports or project in real-time
• Low battery indication and auto shut off
Included
• USB (Type-C) Cable
• Power Adapter
• 2 Rechargeable Batteries
• 32GB Micro SD Card
• Hard Carrying Case
www. .com information@itm.com1.800.561.8187

Specifications
Imaging and Optical Specifications
Field of View (FOV): 56 x 42°
Focal Length: 4.0mm
Spatial Resolution: (IFOV) 3mrad
Thermal Sensitivity (NETD): <65mK
Image Capture Frequency: 9Hz
Focus: Fixed
Measurement
Temperature Range: -40 to 752°F (-40 to 400°C)
Accuracy: ±3.6°F (2°C) or ±2% of reading,
for ambient temperature at 77°F (25°C)
Resolution: 0.1°F/°C/K
Detector Specifications
Detector Type: Uncooled Vanadium Oxide,
Focal plane array (UFPA)
Spectral Range: 8 to 14μm
IR Resolution: 320 x 240 (76,800 pixels)
Image Presentation and Measurement Analysis
Display: 3.5" color IPS
Color Palettes: 7 (Ironbow/Rainbow/Rainbow(HC)/
Lava/Red-Hot/White-Hot/Black-Hot)
Image Modes: Thermal, Visual Image,
Picture-in-Picture, Fusion
(Thermal Blending)
On-Screen Temperature Markers: 3 (Center/High Temp/Low Temp)
Image Measurement Tools: 5 Points/3 Rectangles/3 Circles/
1 Line (add up to 6)
Emissivity: Adjustable (0.01 - 1.00)
Isotherm: Yes (Below, Above, Interval)
Temperature Span: Automatic/Manual
Temperature Alarm Indicators: High/Low (user adjustable)
continued...
www. .com information@itm.com1.800.561.8187

General Specifications
Image Capture Modes: 2 (Single/Time-Lapse)
Display Resolution: 640 x 480 pixels
Digital Zoom: Yes (2x/4x)
Image Format: JPG
LED Flashlight:
Yes (Dual)
External Memory: Micro SD card
Auto Shut-off : Yes (user adjustable
5/10/20/30/45/60/90 mins)
Tripod Mountable: Yes
Low Battery Indicator: Yes
Power Supply: 3.7V/5200mAh rechargeable
Li-ion battery
Battery Life: Approx. 3.5 hours
Charge System: In Camera or Battery (USB-C)
Charge Time: Approx. 4 hours
PC Connectivity: USB Cable (USB-C)
Software: Yes (download from website)
Software Functionality: Image Analysis/Live Camera Feed/
Report Generation
Software OS Compatability: Windows Vista/7/8/10/11
Supported Languages: English, French, German and
Spanish
Product Certications:
CE, UKCA, IP54, 6.6' (2m) drop test
Operating Temperature: 32 to 122°F (0 to 50°C)
Storage Temperature: 14 to 140°F (-10 to 60°C)
Operating/Storage Humidity Range: 10 to 95%
Maximum Operating Altitude: 6561' (2000m)
Dimensions: 10.2 x 3.9 x 3.8" (260 x 99 x 97mm)
Weight: 1.4lbs (630g)
www. .com information@itm.com1.800.561.8187

Instrument Description
1
3
2
4
5
6
7
8
9
10
16
14
17
18
11
12
13
15
1. USB Port (USB-C)
2. SD Card Slot (Micro SD)
3. Lens Cover
4. LCD Display
5. POWER Button
6. LED Light Button
7. LEFT Button
8. UP Button
9. PLAYBACK Button
10. BACK Button
11. RIGHT Button
12. SET Button
13. DOWN Button
14. Tripod Mounting Hole
15. Infrared Camera Lens
16. LED Lights
17. Digital Camera
18. Trigger
www. .com information@itm.com1.800.561.8187

Display Description
29.1
15.8
1
4 5 6 7 8 9
2
311
10
12
13
1. Center Spot Temperature
2. Maximum Spot Temperature
3. Center Spot
4. Spot Settings (Markup)
5. Image Mode
6. Color Palette Settings
7. Image Measurement Tools
8. Isotherm and Temperature
Span Settings
9. Advanced Menu Settings
10. Minimum Spot on
Temp Scale
11. Minimum Spot Temperature
12. Maximum Spot on
Temp Scale
13 Battery Indicator
Power ON/OFF
Press and hold the POWER button for 5 seconds to power ON. To turn
OFF, press and hold the POWER button for 3 seconds and select "Yes"
from the Shutdown prompt.
If the camera has not been used for a long time or the instrument is not
acclimatized to the environment, the camera may take up to 30 minutes
from start-up to measure temperatures within stated specifications.
www. .com information@itm.com1.800.561.8187

Emissivity
This thermal imager measures infrared energy from the surface of the
object and uses this data to calculate an estimated temperature value.
Surfaces that are good at radiating energy (high emissivity), the emissivity
factor is ≥0.90. Shiny surfaces or unpainted metals are not good at
radiating energy (low emissivity) have an emissivity of <0.6. To more
accurately measure materials with a low emissivity, an emissivity correction
is necessary. Emissivity is set directly as a value or from a list of emissivity
values for some common materials.
The following table gives typical emissivity of some materials:
Material Emissivity
Asphalt 0.95
Concrete 0.95
Hard plaster 0.90
Wood (natural) 0.93
Lime Stone 0.98
Ballast chipping 0.95
Paper (every color) 0.95
Plastics non lm 0.95
Tissue (fabric) 0.95
Sand 0.90
Glass wool 0.90
Melted asphalt 0.93
Screed/pavement 0.93
Foamed polystyrene 0.94
Material Emissivity
Drywall 0.95
Render 0.94
Smoothing cement 0.90
Lacquer 0.92
Latex paint 0.97
Wallpaper 0.93
Tilling 0.93
Parquet oor 0.90
Laminate 0.90
PVC-Floor 0.92
Brick 0.93
Cliff 0.97
Roong cardboard 0.93
Stucco 0.91