Renogy REGO Manuale utente

VERSION A1
Lithium Iron Phosphate Battery
REGO
12V
400Ah
QUICK GUIDE

Contents
Package Contents .................................................................................................01
Wiring Diagram......................................................................................................02
Product Overview ..................................................................................................03
Power Connection .................................................................................................04
Communication......................................................................................................07
Turning On.............................................................................................................10
LED Indicators.......................................................................................................11
Heater Settings......................................................................................................14
Turning Off.............................................................................................................16
Maintenance..........................................................................................................17

01
Package Contents
Quick Guide ×1
VERSION A0
Lithium Iron Phosphate Battery
REGO
12V
400Ah
QUICK GUIDE

02
Wiring Diagram
Using Battery Combiner Box and System Combiner Box
Single Battery
System Combiner Box
Battery
Combiner
Box
System
Combiner Box
Positive Negative
Inverter DC-DC
Charger
DC Distribution
Panel
Charge
Controller
Inverter DC-DC
Charger
DC Distribution
Panel
Charge
Controller
Multiple Batteries
Using Anderson Connector to Ring Terminal Adapter Cables
Positive Negative
Single Battery
Multiple Batteries
Positive Busbar
Negative Busbar
Positive Busbar
Negative Busbar
Inverter DC-DC
Charger
DC Distribution
Panel
Charge
Controller
Inverter DC-DC
Charger
DC Distribution
Panel
Charge
Controller
zThis Quick Guide contains important installation, operation, and maintenance instructions for the REGO
12V 400Ah Lithium Iron Phosphate Battery. Please read the Quick Guide carefully before using.
zIllustrations in the Quick Guide are for reference only.
zFor more detailed instructions, please refer to the user manual at renogy.com.
zFor additional support, please contact our customer service through renogy.com/contact-us/.

03
Product Overview
Wiring Diagram
61 532 4
No. Part No. Part
1 Gray Anderson 350 Connector (with Dust Cover) 4 Heater Status Indicator
2 Power Button 5 Battery Level Indicator
3 Battery Status Indicator 6 CAN Communication Ports
zPlease inspect the battery for any visible damage including cracks, dents, deformation, and other visible
abnormalities before installation.
zDO NOT puncture, drop, crush, burn, penetrate, shake, or strike the battery.
zDO NOT touch the exposed electrolyte or powder if the battery is damaged.
zDO NOT open, dismantle, or modify the battery.
zPlease wear proper protective equipment and use insulated tools during installation.
zPlease ensure adequate and secure mounting of the battery.
zPlease install the battery in a clean, cool, and dry place. Keep water, oil, and dirt away from the battery.

04
Power Connection
zPlease ensure that the Anderson Connectors are fully seated and/or the ring terminals are secured to the
proper specification.
zThe Anderson Connectors are color coded. DO NOT mate the Anderson Connectors with different colors
together.
zDO NOT short the contacts of the Anderson Connector. Short circuits can damage the battery.
zPlease check the polarity before connecting the cables. Reverse polarity can damage the battery and
connected devices.
zPlease size the cables appropriately to handle the expected current. Refer to the user manuals of the
battery and connected devices for more details.
zDO NOT connect batteries in series. Series connection can damage batteries.
zDO NOT mix battery brands, models, chemistries, nominal voltages, and rated capacities.
zDO NOT connect more than 8 batteries in parallel.
Using Battery Combiner Box and System Combiner Box
Connecting batteries to the system using the Battery Combiner Box and the System Combiner Box
significantly reduces the risk of short circuit, misconnection, or connection failure and allow for quick
connection or disconnection.
Recommended Accessories
REGO 3 Ports 400A Battery
Combiner Box
REGO 4 Ports 400A System
Combiner Box
zPlease read the user manual
of REGO 3 Ports 400A
Battery Combiner Box and
REGO 4 Ports 400A System
Combiner Box at renogy.com
before the connection.
1.1.1 1.1.2
Remove the Dust Covers from
the Anderson Connectors.
Plug the Anderson Connectors of the batteries to the Battery Combiner
Box (sold separately) for parallel connection.

05
Power Connection
Power Connection
1.1.3
If necessary, connect multiple
Battery Combiner Boxes to
accept more batteries in parallel.
1.1.4
Connect the Battery Combiner
Box and the System Combiner
Box (sold separately) using the
Anderson connectors on their
sides.
1.1.5
If only one battery is used,
connect the battery directly to the
Anderson connector on the side
of the System Combiner Box.
1.1.6
-
+
Connect the devices to the
corresponding Anderson
connectors or insert terminals on
the top of the System Combiner
Box. Refer to the user manual
of REGO 4 Ports 400A System
Combiner Box at renogy.
com to confirm what devices
the Anderson connectors
respectively correspond to.
zIf the devices are connected to the insert terminals of the System Combiner Box, please install appropriately
sized fuses or circuit breakers in the branch circuits to protect connected devices and circuit wires.
zIf the devices are connected to the Anderson connectors of the System Combiner Box, please install
appropriately sized NH fuses (sold separately) in the System Combiner Box to protect connected devices
and circuit wires.

06
Power Connection
Using Anderson Connector to Ring Terminal Adapter Cables
Recommended Accessories
Gray Anderson 350 Connector to
Ring Terminal Adapter Cable Positive/Negative Busbars
zPlease ensure equal length of
the Adapter Cables to make
the batteries operate equally
together.
zPlease size the Busbars
appropriately to handle
the continuous charge and
discharge current of the
batteries.
zDO NOT short the positive
and negative ring terminals
of the Adapter Cable. Short
circuits can damage the
battery.
1.2.1 1.2.2
Remove the Dust Covers from the
Anderson Connectors.
Connect the Anderson Connectors of the batteries to the Adapter
Cables (sold separately).
1.2.3
+
-
1.2.4
-
+
Connect the positive and negative ring terminals
of the Adapter Cables to the Positive and Negative
Busbars (not included) respectively.
Connect the devices to the Positive and Negative
Busbars.
zPlease install appropriately sized fuses or circuit breakers in the branch circuits to protect connected
devices and circuit wires.

07
Communication
Power Connection
The communication connection is optional. It allows the battery to communicate with other REGO devices and
monitoring devices, enabling safe operation, smart control, remote monitoring, and programmable settings.
Inter-Device Communication
Depending on the installation condition, the RV-C communication connections between the battery and other
REGO devices can be established with backbone or daisy chain topology. The inter-device communication
allows the battery to dynamically adjust the charging profile for an optimal and safe charge.
Backbone Topology
If an RV-C bus is pre-installed in the RV, check the network wiring diagram provided by the RV manufacturer
and follow the backbone topology for the RV-C communication connections. Refer to the user manual of the
battery at renogy.com for more details.
Daisy Chain Topology
If the RV-C bus is not available, follow the daisy chain topology for the communication connections.
Recommended Accessories
LP16 Plug (7-Pin) Communication Cable LP16 Terminator Plug (7-Pin)
2.1.1.1
Daisy Chain Topology Connect the battery to other
REGO devices in series through
either of the CAN Communication
Ports with the Communication
Cables (sold separately).
Plug the Terminator Plug (sold
separately) into the free CAN
Communication Ports on the first
and last REGO devices.

08
Communication
Monitoring Device Communication
Depending on the application, the short-range or long-range communication connections can be established
between the battery and the monitoring devices. The monitoring device communication allows for the
monitoring and programming of the battery or even the complete system.
zPlease scan the QR code on the last page of the Quick Guide to download the DC Home app.
zPlease make sure that the battery is turned on before the connection.
Short-Range Monitoring
If only short-range monitoring is required, connect the battery to the DC Home app directly through Bluetooth.
2.2.1.1
Short-Range Monitoring Click "+" to search for new
devices. Add the newly found
battery to the device list. Monitor
the battery on the device page.
Long-Range Monitoring
If long-range communication and programming are required, connect the battery to Renogy Super Panel
through Bluetooth or hard wire, and the Super Panel to the DC Home app through WiFi or cellular network.
zPlease make sure that the Super Panel is powered on before the connection.
zPlease read the user manual of Renogy Super Panel at renogy.com before the connection.
Recommended Accessories
Renogy Super Panel LP16 Plug (7-Pin) to RJ45
Communication Adapter Cable
Altri manuali per REGO
8
Indice
Altri manuali Renogy Accessori per fotocamere

Renogy
Renogy PHOENIX 200 Manuale utente

Renogy
Renogy RBT100LFP12SH-AU Manuale utente

Renogy
Renogy 50LFP48S Manuale utente

Renogy
Renogy RBT100LFP12SH Manuale utente

Renogy
Renogy RBT100LFP12-BT-US Manuale utente

Renogy
Renogy RBT50LFP48S Manuale utente

Renogy
Renogy RBT50LFP48S-AU Manuale utente

Renogy
Renogy REGO RBT12400LFPL-SHBT-US Manuale utente

Renogy
Renogy RBT100LFP12S-US Manuale utente

Renogy
Renogy Core Series Manuale utente

















