EXMUX®3500 IP Access Multiplexer
Quick Start Guide
Table of Contents
1. Overview
............................................................................................................................ 1
2. Connecting Alarm Relays and Power
................................................................................... 2
3. Installing the eXmux 3500 Visual Network Management Software (VNMS)
........................ 6
4. Setting IP Addresses through the USB Interface
................................................................. 8
5. Entering the Activation Key Code and Starting VNMS
........................................................ 16
6. Related Documentation
..................................................................................................... 19
1. Overview
Before the eXmux 3500 can be configured into a network, the Visual Network Management Software
(VNMS) needs to be installed onto the user’s laptop or PC. After this is done, IP address and other
limited settings can be changed through the USB port on the eXmux 3500.
The following instructions are designed to get the user up and running quickly after receiving their
eXmux 3500 IP Access Multiplexer. These instructions are not to be used as a substitute for the
RFL Instruction Manual. Please refer to the Instruction Manual for detailed installation procedures,
set-up, and Interface Unit configuration. Note, once VNMS is installed on your computer the
Instruction Manual can be accessed through a short cut icon that is automatically placed on your
desktop. The Instruction Manual can also be accessed from the “Help” pull-down menu in VNMS.
This Quick Start Guide will give instructions on:
•Connecting Alarm Relays and Power.
•Installing the VNMS software into the user’s laptop or PC.
•Changing IP address information through the USB port on the eXmux 3500.
•Activating the software through a key code and starting VNMS.
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

2. Connecting Alarm Relays and Power
The following section describes how to connect Alarm Relays and Power to the eXmux 3500.
Before beginning the installation note the following:
•RFL recommends that wires only be terminated with ring lugs.
•The specified operating temperature of the eXmux 3500 is -30°C to +65°C
(-22°F to +149°F). Operation at higher temperatures may affect system reliability and
performance. Systems installed in enclosed cabinets should be well ventilated. A full 1U of
chassis space must be left open above the installed eXmux 3500.
•Before proceeding with the connection of power to the eXmux 3500 ensure that the main and
redundant power switches on the rear of the eXmux are in the “OFF” position, and that the
power wires to be installed are disconnected at their source.
•All relay contacts are labeled in the de-energized position.
•Ensure that the power supply(ies) installed in your eXmux 3500 will operate at the
available input power.
•Follow all of your company’s policies and procedures regarding the installation of AC powered
or DC powered equipment. If there is a conflict between any procedure in this Quick Start
Guide and your company’s safety rules, then your company’s safety rules must take priority.
CAUTION
Any installation using an enclosed cabinet with a swing-out rack must be securely fastened to the
floor. This will prevent the cabinet from falling forward when the rack is moved outward.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 2 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

Alarm Relay Connections
MAJOR
MINOR
NCNO CNCNO C
The alarm relays on the unit will respond to alarm and alert conditions, the functionality can be
programmed by the user as required and connected to their plant monitoring system. Under normal
operating conditions when the eXmux 3500 is turned on the relays are energized, in an alarm or
alert state the relays will be in the de-energized position.
Connect the Alarm Relays as required.
Connecting Power
The eXmux 3500 has labels located below the power ON/OFF switches that indicate which power
supply(ies) were installed in the unit before leaving the factory. Note that units are shipped with
two switches installed. If a redundant power supply is not installed on your unit, no label will
be present under the redundant power supply switch as shown on the following page. Main
and redundant power supplies do not have to be the same.
Before proceeding with the power and ground wire installation check the power supply labels to
ensure that the unit will operate at the input voltage available.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 3 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

O
I
O
I
MAIN REDUNDANT
Label for a standard power
supply is shown
50/60 Hz38-150 V
3A MAX
WARNING!
The eXmux 3500 chassis must be properly grounded as described below before attempting to
connect input power. Improper ground connections may result in system malfunctions, equipment
damage, or electrical shock.
Grounding is accomplished by connecting a 6 AWG wire, or larger between the protective earth stud
shown below and the rack ground. The grounding wire should be kept as short and straight as
possible, to keep its resistance and inductance to a minimum.
Chassis Protective
Earth Terminal
!
MAJOR
Rear of eXmux
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 4 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

WARNING!
Individual double pole disconnects must be installed between the building or station battery supply and
the eXmux 3500 power supply(ies). This must be done for both the main and redundant supply.
Before proceeding with the connection of power to the eXmux 3500 ensure that the main and
redundant power switches on the rear of the unit are in the “OFF” position as shown in the illustration
below, and that the power wires to be installed are disconnected at their source.
MAIN
++
--
RDNT
Main Power Supply
On-Off Switch Redundant Power Supply
On-Off Switch
Input power connections can be either (24 Vdc, 48/125 Vdc, 250 Vdc) from a station battery, 120 or
220 Vac depending on which power supplies are installed in the unit. Make the required connections
as shown in the illustration above. Station battery positive goes to the “+” terminal and station battery
negative goes to the “-” terminal. If ac input power is used connections are made to the “+” and “-”
terminals and the polarity markings can be ignored.
Before connecting the power at its source and switching on the eXmux 3500, check the following:
1. Is the unit grounded correctly?
2. Is the polarity of the input power correct?
3. Is the unit ventilated correctly?
The eXmux 3500 may now have power applied.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 5 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

3. Installing the eXmux 3500 Visual Network
Management Software (VNMS)
The following section describes how the eXmux 3500 Visual Network Management Software (VNMS)
is installed into your Laptop or PC.
Computer and Operating System Restrictions
•The eXmux 3500 Visual NMS is compatible with Windows XP®Service Pack 2 or higher,
Windows Vista®and Windows 7®Operating Systems; currently when using Vista or Windows
7 Operating Systems certain changes must be made to file locations after the VNMS software is
installed. These changes are described after the software is installed in the steps below.
•An Intel Pentium D (dual core) 2.5 GHz or higher processor computer is recommended with a
minimum of 1 gigabyte of RAM. 2 gigabytes of RAM is recommended.
•RFL recommends that a high resolution screen be used for optimal VNMS viewing.
Before beginning the installation note the following:
•The eXmux 3500 Visual NMS software is conveniently loaded into the user’s laptop or PC
through the supplied CD (Part # MCD3500-XXX) or downloaded from the RFL website at
www.rflelect.com.
Installing VNMS
Follow the steps below to install the software.
1. Insert the CD into the CD ROM drive of your computer or run the downloaded file.
2. In most cases, a setup window will appear on the screen. Click Install.
If the window does not appear, do the following:
a. From the Start Menu, select run.
b. Type the following in the run window command line: D:\setup
Note: If your computer does not use ‘D’ for the CD ROM drive, substitute the correct
letter here.
c. Click OK.
3. Click on ‘Next’ to continue with the setup.
4. From this point on the software will prompt you to enter information it requires to complete the
installation.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 6 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

5. Windows XP users can skip to Step 6. For Vista and Windows7 users, at the “Installation
Folder” dialog, the path for the installation of the VNMS software needs to change. The
procedure to do this is described below.
a. Click “Change” and enter the path “C:/Users/Public/Documents/Exmux 3500 Visual
NMS” in the “Where would you like Visual NMS Installed.” field.
b. Click Next.
6. When the installation is complete the following icons will appear on your desktop, clicking an
icon will display its full description.
Shortcut to the Visual
Network Management
Software (VNMS)
Shortcut to launch the terminal
program to allow IP programming
through the "User Access USB" port
Installing VNMS over a previous version
The VNMS software is now installed on your computer. Below are instructions for upgrading VNMS
over a previous version.
1. Uninstall the previous version of the Visual NMS
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 7 973.334.3100
2. Run the install set-up, for Windows XP operating systems simple click “Next” and
complete the software installation. For Windows 7 or Vista proceed as follows:
3. Step through the screens clicking next until you reach the screen named “Installation
Folder.” Click “Change” and enter the path “C:/Users/Public/Documents/Exmux 3500
Visual NMS” in the “Where would you like Visual NMS Installed.” field.
4. Click “Next.” The new version of VNMS will be installed onto your Laptop or PC.
Note: Before VNMS can be used the original activation key code may need to be entered.
Call RFL Customer Service at 973.334.3100 for key code information if necessary.
The following sub-section will show you how to connect to the eXmux 3500 through a USB port in
order to set IP Address information and other limited settings.
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

4. Setting IP Addresses through the USB Interface
The following section describes how to connect a laptop or PC through either the front or rear USB
port on the eXmux 3500. This is done in order to set the Management IP address, Subnet Mask,
Gateway IP Address and Multicast IP Address in the eXmux 3500.
Before beginning the installation note the following:
•The user will need to supply a USB cable with a type ‘B’ connector at the eXmux end.
•Only one USB connection is possible at one time.
•The following instructions are based on Windows7®(64 bit) operating system and
Windows XP®Operating System (XP service pack 2 or above), other Windows systems
will be similar.
•Currently RFL supplies a USB Driver for Windows7 (32 and 64 bit) operating system
users. The driver can be downloaded from the RFL website or supplied on a CD or other
electronic media. Once the driver software is copied to your computer the following steps
are required to configure the driver:
Use a type "B"
connector at the eXmux
Typically a type "A"
connector is used at the
laptop
After the USB cable is installed, windows will automatically detect the eXmux 3500 USB port. The
following dialog boxes will appear for Windows7 users. XP user’s go to page 13.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 8 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

Windows 7 Operating System
After a USB cable is connected to an eXmux and the user’s computer go to the “Start” menu and
follow the steps below. Note; there are two parts to this configuration process. The USB Interface and
the USB Serial Port, both parts MUST be completed to correctly configure the USB Driver.
Double click on
"Exmux 3500 USB
Interface"
Select the
"Hardware" tab
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 9 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.

1. Configuring the USB Interface:
With the “Hardware” tab selected proceed as follows.
Select "Browse my computer
for driver software"
Browse to where the Driver Software is
located on your computer
Ensure this
box is
checked
Select the USB Driver
and click "Next"
Select "Install this driver
software anyway
Select
Select
Select "Update
Driver"
Click “Close” a confirmation window will appear as shown on the following page.
EXMUX 3500 Quick Start RFL Electronics Inc.
May 29, 2013 10 973.334.3100
Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.