Ries Hitachi Highly WHP15600VSDPC9EQ Manuale utente

HitachiHighly
Rollkolbenverdichter
Rotary Compressors
Spezifikation
Installation Manual
WHP15600VSDPC9EQ
RIES GmbH, Rudolf-Diesel-Str. 10, D 64569 Nauheim, GERMANY
R 410A- R 452B- R 454C - R 454B
42 cm3/rev
900 - 7200 min-1
DC / BLDC
10/19

Table of Contents
I.WHP15600VSDPC9EQ Specifications ——————— 1~4
1.Application area
2.Compressor specifications
3.Motor parameters
4.Parts and drawings list
5.General characteristics
II.: Heat pump water heater dedicated
compressor reference 5 - 15
III. Acceptance ----------———— 16
1. Acceptance basis
2. Acceptance rules
IV.the drawings ———————————— 17~30
V. :Modification of Specification ——————Appendix

SUBJECT
M od el W HP1 56 00 VS DPC 9E Q SP ECI FI CA TI ON PAGE:1/30
1. SCOPE
This specification is applied to SHANGHAI HIGHLY
Heat pump water heater compressor.
2. SPECIFICATION OF THE MODEL
Item Spec
2.1 Model Type WHP15600VSDPC9EQ
2.2 Power source input to inverter
Rated voltage / Rated frequency/Phase
380V/50Hz/3Ф OR 220V/50HZ/1Ф
2.3 Output 3850W/3690W/2430W/3650W
(R410A/R452B/R454C/R454B @3600min-1)
2.4 Application Heat pump water heater
2.5
Performance
Refrigerant R410A R452B R454C R454B
Item Rated Condition Rated Condition Rated Condition Rated Condition
Rotational speed 3600 min-1 3600 min-1 3600 min-1 3600 min-1
Nominal Heating Capacity 17400W 16880W 11940W 16750W
Motor input 4160W 3990W 2640W 3950W
Current 16.2A 15.8A 11.0A 15.6A
COP(see*) 4.18 4.23 4.52 4.24
Test Conditions
Evaporating temp. 7.2℃ 7.2℃ 7.2℃ 7.2℃
Condensing temp. 54.4℃ 54.4℃ 54.4℃ 54.4℃
Liquid temp. entering
expansion valve. 46.1℃ 46.1℃ 46.1℃ 46.1℃
Return gas temp. 35℃ 35℃ 35℃ 35℃
Ambient temp. 35℃ 35℃ 35℃ 35℃
Wind speed 2m/s 2m/s 2m/s 2m/s

SUBJECT
Model WHP15600VSDPC9EQ SPECIFICATION PAGE:2/30
*.COP= Heating capacity
Motor input (W)
*.Rated Capacity and input are measured with HIGHLY inverter circuit by secondary Refrigerant
calorimeter Methods of JIS B8606 by Shanghai HIGHLY Electrical Appliances Co., Ltd.
Allowable capacity should be more than 95% of the rated capacity and allowable input
should be less than 107% of rated motor input.
2.6 Refrigerant R410A/R452B/R454C / R454B
2.7 Displacement 42.0ml /rev( Double-cylinder )
2.8 Allowable frequency range 900~7200 min-1
2.9 Oil α68HES-H or equivalent 1650±20ml
2.10 Allowable amount of refrigerant
charge Below 4500g
2.11 Compressor cooling Forced air 强制空冷
2.12 Hermetic Terminal Conventional type
2.13 Space volume of inner case 2628cm3
2.14 Compressor weight 19.5kg incl. Oil
2.15 Motor Type
Insulation class Direct current brushless motor E class
2.16 Compressor natural frequency 19.9Hz/21.7Hz/24.5Hz
(Should try to avoid or quickly pass)
3. THE PARAMETER OF MOTOR
Item Spec参 数explanation
3.1 Rotor Pole(Pole)4 ——
3.2 Rated Frequency Range(Hz)30-240
Electrical Frequency,Relating to
VDCmax of Inverter
3.3 Demagnetizing Current(A)54.01A Peak Current,at 120℃,-5%
Demagnetizing Rate

SUBJECT
SPECIFICATION
M od el W HP1 56 00 VS DPC 9E Q PAGE:3/30
2
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
q 5.44 5.39 5.34 5.29 5.24 5.18 5.12 5.06 5.00 4.95 4.89 4.83 4.78 4.72 4.66
d 3.71 3.65 3.65 3.64 3.63 3.61 3.59 3.56 3.54 3.51 3.48 3.45 3.42 3.39 3.36
4. CHARACTERISTICS
4.1. Appearance
The surface of the compressor is painted to black, without obvious flaw ,impact scar, paint peel
off, rust and so on.
4.2. Indication
Compressor model type, manufacturing data are clearly indicated on the surface of compressor。
4.3. Residual moisture 300mg MAX
4.4. Residual impurities 150mg MAX
4.5. Dielectric withstand
A 1500V alternating voltage for 1minute should be applied between live parts and dead metal parts.
3.4 Inductance Ld(mH) Sheet 2 ——
3.5 Inductance Lq(mH)Sheet 2 ——
3.6 Stator coil resistance(20℃)(Ω)
0.502(20℃) line-to-line
3.7 Voltage Constant(Vrms/krpm)43.10V/krpm line-to-line
3.7 Torque Constant(N·m/Arms)0.69 Torque/Current
3.9 Inertia (Kg·m2)0.000666
3.10 Flux Φa(Wb)0.1702
φ(Per Phase,Peak)= 32
02
f
E
π
×
φ(一相 peak 值)= 32
02
f
E
π
×
3.11 Magnet Material NdFeB
Electric current

SUBJECT
SPECIFICATION
M od el W HP1 56 00 VS DPC 9E Q PAGE:4/30
5 PARTS AND DRAWING LIST
PARTS NAME QTY/SET DRAWING NO. REMARKS
Compressor 1 4CYCH**** Dimensioned sketch
Mounting
Parts
Rubber grommet
B
olt
N
ut
3
--
--
4CYC00643
4CYC00700
M8
*
*
Electrical
Parts
T
hermostat
T
erminal cover
G
asket
N
ut
Rubber washer
Sleeve
1
1
1
1
1
1
4CYC01036
4CYC00988
4CYC01047
3CYC00004
4CYC00174
4CYC01042
4CYC01272
1
2
3
Lead routing
Pressure guarantee
Chart
Notes for rotational
speed change
Performance
curve
Appendix
*. Out of supply, for reference.

HEAT PUMP WATER HEATER COMPRESSOR CRITERIA
PAGE:5/30
COMPRESSOR CRITERIA
1 Strictly observe the specification
The compressor should be used in specifications written in this “compressor specification” and
not be used in specifications outside it.. The main circuit must link up with fuse or breaker.
2 Source voltage
Specified inverter is linked up with compressor terminals . Applied voltage of this inverter
should be voltage specified in this “compressor specification”. Alternating voltage should
never be applied on terminals (for example:commercial alternating voltage of
1φ100V,200V,3φ200V).This is because that if applied alternating current the direct current
motor will demagnetize.
3 Operating voltage range
The compressor should be operated in the range of rated voltage ±10% , under standard condition
and overload condition of rated frequency (applied voltage to inverter).It must be satisfied
with item 5 ,6,7.
4 Operating temperatures and pressures
The operating temperatures and pressures of a compressor should be within the range shown in
the table 2 and graph 1.
5Oil Back and oil level
The oil should be returned continuously to the compressor and the structure of the refrigerating
system should not make oil stay in the system. The oil level in compressor should be satisfied
with chart 2.If not keep the oil level, the shortage will occur, and influence the reliability of
the compressor.(please check the oil level in the compressor with the sight glass which supplied
form SHEC.

HEAT PUMP WATER HEATER COMPRESSOR CRITERIA PAGE:6/30
The oil should be continuously returning to the compressor to oil, and there
should be no
oil storage part in the refrigeration system construction. And, the oil level
in the compressor should meet the figure 2
conditions of. However, when foaming occurs and the liquid becomes foamy,
this part is not an oil level. If you cannot meet the high oil level
degree, will cause the sliding part of the oil supply, seriously affecting
the reliability. (Can be confirmed with a sight glass-equipped compressor for
oil level observation).
Table 2
Item Operating Envelope
(see graph 1)
Refrigerant R410A R452B R454C
Discharge pressure
MPa
4.762 max
Condensing temperature
:70℃)
4.492 max
(condensing temperature
:70℃)
3.465 max
(condensingtemperature
:75℃)
Suction Pressure
MPa
0.272~1.652 0.254~1.562 0.172~1.084
(Evaporation Temperature :-30℃~25℃)
It can also be 0.101~0.172 MPa when in transition
but should not be used when it is less than 0.101MPa
Compressor case
bottom temp
99℃or below and 6 degrees
higher than condensing temperature
Motor winding temp Rated voltage: : 105℃ MAX R.Voltage±10%:
120℃ MAX
Accumulator temp Higher than outlet pipe of evaporator
Ambient temp Meet for the condition of above mentioned motor winding temp.

HEAT PUMP WATER HEATER COMPRESSOR CRITERIA
PAGE:7/30
0
10
20
30
40
50
60
70
80
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30
Evaporating Temp.(℃)
Condensing Temp.(℃)
R410A
R452B
P2
P1
P3
P4
P5
Graph 1(a)
P1 P2 P3 P4 P5
Condensing temperature 70℃28℃5℃45℃70℃
Evaporation Temperature 25℃25℃-30℃-30℃-5℃
0
10
20
30
40
50
60
70
80
-35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30
Evaporating Temp.(℃)
Condensing Temp.(℃)
R454C
P1
P2
P3
P4
P5
Graph 1(b)
P1 P2 P3 P4 P5
Condensing temperature 75℃28℃5℃65℃75℃
Evaporation Temperature 25℃25℃-30℃-30℃-10℃
6 Current limitation
Current peak among motor terminals(include instantaneous current peak)should be
below demagnetizing current in order to prevent magnet in motor from demagnetization.
7 Pressure difference between suction and discharge
In all allowable rotational speed range, the difference of pressure should be more than
0.39MPa{4kgf/cm2}. But if there is no problem of noise when assembled in air conditioner,
it can also below this value.
+ R 454B

HEAT PUMP WATER HEATER COMPRESSOR CRITERIA
PAGE:8/30
8 Discharge pipe temperature
Discharge pipe temperature is measured at a distance 300mm from the surface of compressor
and should be less than 110℃. The tip of the thermocouple is fixed by soldering when
measuring discharge pipe temperature .Furthermore, soldering point is covered with urethane
foam to prevent the effect of wind.
9 Dust of compressor hermetic terminals
Compressor hermetic terminals should be mounted with specified cover in right way to prevent
dust entering, and should be used in direction which dust is hard to enter in.
10 Lead wire of compressor hermetic terminals
Measuring the temperature of hermetic terminals , lead wire should be resist to the temperature
and be clamped so as not in touch with the surface of compressor and pipe.
11 Start-stop frequency
The frequency should be less than 6 times per hour. Operating time from start to stop should
be more than 3 minutes. Stopping time should be more than 3minutes.
。
12 Rate of rotational speed change
The rate of compressor rotational speed (acceleration) should be less than 133min-1/s, But if
The variable range is below 120min-1, rate can also be less than 600min-1 when rotational
speed is reduced to avoid temporary over- current.
13 Air and moisture in refrigerating system
The degree of vacuum in refrigerating system should be less than 20Pa (150×10-3mmHg) at
room temperature just before charging refrigerant. The quantity of water should be less
than 0.15ml.