6
Diagramshows
minimum
clearances from
combustible
materials
ofthecontrolsystemandanygascontrol
whichhasbeen underwater.
17 Adequateclearancesforaccessibilityfor
purposes of servicing and proper
operationshould beprovided.
18 Adequate clearances around air
openingsinto thecombustion chamber
shouldbe provided.
19 Do not install in areas where curtains,
drapes, clothing, or other moving
flammables are within 15 inches of this
unit.
24 The drafthood onthe applianceshould
be installed in the same atmospheric
pressurezoneasthecombustionairinlet
tothe applianceandshall belocatedso
that the relief opening is accessible for
checkingvent operation.
25 The appliance,when installed,mustbe
electricallygroundedinaccordancewith
local codes or, in the absence of local
codes, with the National Electrical
Code,ANSI/NFPA70, orthe Canadian
Electrical Code, CSA C22.1
26 A gasappliancemust notbeconnected
to a chimney flue serving a solid fuel
burningappliance.
27 Do not restrict the warm air discharge
byplacing articlesin frontofheater.
28 Thisappliancemustnotbeusedforany
purposeotherthan heating.
29 Do not allow anyone to post articles
throughthelouvres.
30 Do not allow anyone to sit or lean
againstthe appliance.
31 DUETOHIGHTEMPERATURES,THE
APPLIANCE SHOULD BE LOCATED
OUT OF TRAFFIC ANDAWAY FROM
FURNITUREANDDRAPERIES.
32 CHILDRENANDADULTSSHOULDBE
ALERTED TO THE HAZARDS OF
HIGH SURFACE TEMPERATURES
ANDSHOULD STAYAWAYTOAVOID
BURNSORCLOTHINGIGNITION.
33 CLOTHING OROTHER FLAMMABLE
MATERIALSHOULDNOTBEPLACED
ONOR NEARTHEAPPLIANCE.
34 INSTALLATIONANDREPAIRSHOULD
BEDONE BYAQUALIFIEDSERVICE
PERSON. THEAPPLIANCESHOULD
BE INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A
PROFESSIONALSERVICEPERSON.
MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE
LINT FROM CARPETING BEDDING
MATERIAL, ET CETERA. IT IS
IMPERATIVE THAT CONTROL
20 Periodic examination of the venting
systemis required.
21 The flow of combustion and ventilation
airshould notbe obstructed.
22 A manufactured home (USA only) or
mobile home OEM installation must
conform with the Manufactured Home
ConstructionandSafetyStandard,Title
24CFR, Part 3280, or, when such a
standardisnot applicable,theStandard
for Manufactured Home Installations,
ANSI/NCSBCSA225.1 orStandard for
Gas Equipped Recreational Vehicles
and Mobile Housing, CSA Z240.4.
23 The appliance and its appliance main
gasvalvemustbedisconnectedfromthe
gas supply piping system during any
pressure testing of that system at test
pressuresinexcessof 1/2psi(3.5kPa).
Theappliancemustbeisolatedfromthe
gas supply piping system by closing its
equipment shutoff valve during any
pressuretestingofthegassupplypiping
systematpressuresequaltoorlessthan
½ psi (3.5 kPa).
36”
ABOVE
12”
RIGHT
12”
LEFT
36”
FRONT