RKI 82-5201-01 Manuale utente

2• 82-5201-01 Email/Text Generator Operator’s Manual
Product Warranty
RKI Instruments, Inc. warrants gas alarm equipment sold by us to be free from defects in
materials, workmanship, and performance for a period of one year from date of shipment from
RKI Instruments, Inc. Any parts found defective within that period will be repaired or replaced, at
our option, free of charge. This warranty does not apply to those items which by their nature are
subject to deterioration or consumption in normal service, and which must be cleaned, repaired, or
replaced on a routine basis. Examples of such items are:
• Absorbent cartridges
•Fuses
• Pump diaphragms and valves
•Batteries
• Filter elements
Warranty is voided by abuse including mechanical damage, alteration, rough handling, or repair
procedures not in accordance with the operator’s manual. This warranty indicates the full extent
of our liability, and we are not responsible for removal or replacement costs, local repair costs,
transportation costs, or contingent expenses incurred without our prior approval.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ANY AND ALL OTHER WARRANTIES AND
REPRESENTATIONS, EXPRESSED OR IMPLIED, AND ALL OTHER OBLIGATIONS OR
LIABILITIES ON THE PART OF RKI INSTRUMENTS, INC. INCLUDING BUT NOT LIMITED TO,
THE WARRANTY OF MERCHANTABILITY OR FITNESS FOR APARTICULAR PURPOSE. INNO
EVENT SHALL RKI INSTRUMENTS, INC. BE LIABLE FOR INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL LOSS OR DAMAGE OF ANY KIND CONNECTED WITH THE USE OF ITS
PRODUCTS OR FAILURE OF ITS PRODUCTS TO FUNCTION OR OPERATE PROPERLY.
This warranty covers instruments and parts sold to users by authorized distributors, dealers, and
representatives as appointed by RKI Instruments, Inc.
We do not assume indemnification for any accident or damage caused by the operation of this gas
monitor, and our warranty is limited to the replacement of parts or our complete goods.

82-5201-01 Email/Text Generator Operator’s Manual • 3
Table of Contents
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Entering Configuration Mode and Initial Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
WiFi Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Soft AP Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Email Client Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Calibration Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Power On and Input Emails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4• Overview 82-5201-01 Email/Text Generator Operator’s Manual
Overview
The 82-5201-01 email/text generator is capable of monitoring 4 sets of contacts and sending out
an email and/or text message when a contact opens or closes. It can also send out an email and/or
text message when it is powered up.
The email/text generator is installed in a plastic housing that has a strain relief bushing on the
bottom. An AC/DC power supply is installed beneath the email/text generator. The power
supply’s AC input terminals are wired to a terminal strip at the bottom of the mounting plate to
make it easy to connect power at the installation site. The DC output wires are wired to the email/
text generator’s input terminals.
Figure 1: Component Location
Email/Text
Generator
DC Terminal Strip
Power Supply
Strain Relief Bushing
AC Terminal Strip

82-5201-01 Email/Text Generator Operator’s Manual Specifications • 5
Specifications
Input Power
9 - 12 VDC
OR
110/240 VAC
Current Draw 100 mA max
Email Broker
SMTP (what most email brokers, such as Gmail and Outlook, use)
NOTE: Email broker must be SMTP. Password for email account cannot contain
‘&’ symbol. Outlook accounts require verification to send emails/texts to more
than one recipient.
WiFi
2.4 GHz
* Does not support 5 GHz networks, captive portal networks, or networks whose
passwords have special characters such as #$%*
Contacts 4 input contact ports
LED
Flashing White Device is trying to connect to WiFi.
Flashing Green Device is properly connected to WiFi and is ready
for operation.
Yellow Device is booting up.
Flashing Blue 1x/second Device is in Configuration Mode and should
appear as a WiFi network on your computer,
phone, or tablet.
Flashing Blue 2x/second Device is trying to send an email and/or text.
Flashing Random Colors Device is restoring factory default settings.
Single Red Flash Email/text sending failed. It is normal for the gen-
erator to return to flashing green after 5 seconds.
Double Red Flash There is an issue with Device Settings. It is nor-
mal for the generator to return to flashing green
after 5 seconds.
Triple Red Flash WiFi connection cannot be established with con-
figured network.

6• Installation 82-5201-01 Email/Text Generator Operator’s Manual
Installation
1. Select the mounting site. When you select the mounting site consider the following factors:
• Is an AC or DC power source available?
• Is there enough room to open the housing door and make wiring connections
(see Figure 2)?
2. The mounting feet and hardware to install the mounting feet are shipped in a bag inside the
housing. Install the mounting feet as shown below.
3. Position the monitor on a vertical surface at eye level (4 1/2 to 5 feet from the floor).
4. Use 3/16” screws through the slots in the mounting feet at each corner of the housing to secure
the housing to the mounting surface.

82-5201-01 Email/Text Generator Operator’s Manual Installation • 7
Figure 2: Dimensions
Ø 0.21 x 0.33 slot, 4X
10.439.33
5.20
5.98

8• Wiring 82-5201-01 Email/Text Generator Operator’s Manual
Wiring
1. If using AC power:
a. Unscrew and remove the kep nuts from the AC terminal strip’s cover.
b. Route the AC wires through the strain relief bushing on the bottom of the housing.
c. Connect a line wire from the AC power source to the “H” terminal on the AC terminal
strip.
d. Connect a neutral wire from the AC power source to the “N” terminal on the AC terminal
strip.
e. Connect a ground wire from the AC power source to the “G” terminal on the AC terminal
strip.
f. Reinstall the AC terminal strip’s cover using the kep nuts.
Figure 3: AC Wiring
124 3
Input Contacts
NL
AC Power
Source
G

82-5201-01 Email/Text Generator Operator’s Manual Wiring • 9
2. If using a 9 - 12 VDC power source:
a. Disconnect the factory-installed red and black wires from the email/text generator’s input
terminals.
b. Route the DC wires through the strain relief bushing on the bottom of the housing.
c. Connect the power source’s “+” line to the “+” terminal on the DC terminal strip.
d. Connect the power source’s “-” line to the “-” terminal on the DC terminal strip.
Figure 4: DC Wiring
3. Wire the 2 terminals for each Input Contact to the contacts they are intended to monitor. The
inputs can monitor a normally open (NO) contact or a normally closed (NC) contact.
4. Tighten the screw on the strain relief bushing to secure the wires.
5. Turn on the power source.
-+
21
Input Contacts
3
Relay Contacts
DC Power
Source
Common
NO or NC
Common
NO or NC 4

10 • Configuration 82-5201-01 Email/Text Generator Operator’s Manual
Configuration
Entering Configuration Mode and Initial Connection
1. Connect power to the device. If it’s the first time the device has been turned on, it will turn on
in Configuration Mode and the LED will be flashing blue. If the LED is flashing green, press
the Mode button on the right side of the device to switch to Configuration Mode using a tool
with a 90° angle.
2. Navigate to the WiFi screen on your computer, phone, or tablet and find NCD_Email.
3. The password to join the network is NCDBeast.
Indice
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente