Rocstor SolidRack R3300 Manuale utente

®
SolidRack 42U Open Frame Rack
User Manual
Y10E037-B1

Rocstor Legal Disclaimer
Introduction
Dimensions Specication
Important Safety Information
Safety Instructions
Component Identication
Hardware and Accessories
Level the Rack Cabinet
Join the Cabinets
Ground the Cabinet
Five-Year Factory Warranty
Contact Information
1
2
2
3
4
5
6
7
8
9
10
11
Page
Table of Contents

The information presented in this manual is not warranted by Rocstor to be totally authoritative, error free,
or complete. This publication is not meant to be a substitute for a detailed operational and a site-specic
development plan for the use of the product. Therefore, Rocstor assumes no liability for damages, violations
of codes, improper installation, system failures, or any other problems that could arise based on the use of
this Manual.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE LIMITED IN TIME TO THE DURATION OF THE
WARRANTY AS STATED HEREIN AND IS EXCLUSIVE IN LIEU OF ALL OTHER WARRANTIES, LEGAL THEORIES,
REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. IN NO EVENT SHALL
ROCSTOR, OR ANY PARENT, AFFILIATE OR SUBSIDIARY COMPANY OF ROCSTOR OR THEIR RESPECTIVE
OFFICERS, DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE,
SPECIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS,
CONTRACTS, REVENUE, LOST PROFITS, DATA, INFORMATION, GOODWILL OR BUSINESS INTERRUPTION
RESULTING FROM OR ARISING OUT OF THE USE OF THE PRODUCT OR FAILURE TO FOLLOW INSTRUCTIONS
IN THE MANUAL.
FURTHERMORE, ROCSTOR SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES INCLUDING,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IF
ROCSTOR CANNOT LAWFULLY DISCLAIM SUCH IMPLIED WARRANTIES, THOSE IMPLIED WARRANTIES WILL BE
LIMITED IN DURATION TO THE DURATION SET FORTH ABOVE.
FURTHER STILL, ROCSTOR RESERVES THE RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO THE
CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT ANY TIME AFTER PURCHASE WITHOUT
NOTICE.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages
or exclusions or limitations on the duration of implied warranties or conditions, so the above limitations or
exclusions may not apply to you. This warranty gives you specic legal rights and you may also have other
rights that vary by state or province.
Copyright, intellectual, and all other proprietary rights in the content of the manual (including but not
limited to software, audio, video, text, and photographs) rests with Rocstor or its licensor. All rights in the
content are the property of Rocstor and are not granted, licensed, assigned or otherwise passed to the
purchaser’ of the product or to persons having access to the information in the manual
Page 1
Rocstor Legal Disclaimer

Introduction
Dimensions Specication
SolidRack R3300 Premium 42U Standard-Depth 4-Post Open Frame Rack Cabinet – No Doors or Side Panels – Assembled - 3300 lb
(1500 kgs) Static Load Capacity - Includes Casters – Locking – 19” Standard Rack Width – 600mm Wide x 1070mm Deep, 42U
Enclosure - Floor Standing – Heavy-duty Cold-rolled Steel (CRS) – For HP®, Dell®, Lenovo® Servers - For Server, Storage, LAN Switch,
PDU – ROHS & CE Certied – Comparable to SR42UBEXPND - EIA-310-E & IP20 Protection Rating Compliant - Black
This manual provides notes for the general installation and conguration.
Width(mm)
42U 600 1070
Capacity(U) Depth(mm)
Available Rack Dimensions
Depth
(1070mm) - (42.13in)
Hight
(1992mm) - (78.43in)
Width
(600mm) - (23.62in)
Page 2

Important Safety Information
Please review and read the instructions very carefully in order to understand the specication of the equipment. This is
essential information before installing, operating, service or maintaining your equipment. These messages or alerts may appear
throughout this publication and manual for your purchased equipment. The messages are designed to warn you of possible
hazards or to bring to your attention the information that would assist and claries steps and procedures.
DANGER
WARNING
CAUTION
CAUTION
NOTICE
DANGER This symbol represents an imminently hazardous situation which, if not avoided,
will result in death or serious injury. Please follow instructions carefully.
WARNING This symbol represents a potentially hazardous situation which, if not avoided, can
result in death or serious injury. Please follow instructions carefully.
CAUTION This symbol indicates a potentially hazardous situation which, if not avoided, can
result in minor or moderate injury.
CAUTION, This symbol is used without the safety alert symbol, indicates a potentially
hazardous situation which, if not avoided, can result in equipment damage. Please follow
instructions carefully. Please follow instructions carefully.
NOTICE This symbol provides informations and practices not related to physical injury
including certain environmental hazards, potential damage or loss of data. Please follow
instructions carefully.
This is a safety alert symbol. It is used to alert you to potential personal
injury hazards. Please follow the instructions very carefully and obey all
safety messages that follow this symbol to avoid possible injury or death.
This symbol and label provides Danger or Warning safety which indicates
an electrical hazard exists. If instructions are not fully followed, it may
result in personal injury.
Page 3

Safety Instructions
Please follow the essential and important instructions in this manual. The information provides you useful instructions for
installation and customization of the rack or equipment.
• The content of this packaging is easily tipped. Please be extra careful and use extreme caution
when moving or unpacking this cabinet.
• Two people are preferred and are required to move and unpack the cabinet.
• Before moving the cabinet on its casters, load in the means of servers, storage, or other
equipment 159 kg (350 lb) of equipment into rack and place the equipment at the bottom of the
cabinet for additional stability.
• Make sure the leveling feet are up when moving or pushing the cabinet. DO NOT push the
cabinet from its sides.
TIP/ HEAVY EQUIPMENT HAZARD
Not following these instructions carefully, it can result in death, serious injury, or
equipment damage
WARNING
Labels
Look for additional safety information axed to the cabinet.
Page 4

Component Identication
Oprn Frame Rack
Top cover
Frame
Cable management rail
Vertical rail
23
Horizontal Beam
6
7
M12 leveling feet
2 inch casters
4
5
Page 5
1
1
2
3
4
6
7
5

Hardware and Accessories
To ensure proper and secure installation, cage nuts need to be installed horizontally
as shown below. Installing cage nuts in the incorrect orientation can cause injury or
equipment damage.
M6 Cage Nut (50)M6 Phillips-Head Screw (50) Cup Washer (50)
Allen Wrench
Page 6

The leveling feet at the corners of the equipment provide a stable base if the door is uneven, but they cannot
compensate for a badly sloped surface. Ensure the cabinet is in its intended location. Remove the front and
rear doors.
NOTE: Before removing the front door, unplug the ground wires and any other wire connections that may
interfere with the removal of the doors.
NOTE:
• Use an 18 mm open-end wrench to lower each leveler A until it reaches the
oor. (There are 4 levelers, 2 at the front and 2 at the rear.) Make sure each
leveler contacts the oor solidly.
• Adjust each foot and, using a level, adjust the feet until the cabinet is level
and plumb. Do not install the doors until after the cabinet is joined to others
in the row.
Level the Rack Cabinet
Note: Lower a leveler by turning it clockwise; raise a leveler by turning it
counter-clockwise.
Page 7

Join the Cabinets
Join cabinets with the baying brackets option kit included with the SolidRack 42U. Which will provide
alignment and added stability. SolidRack AR3100 cabinets may be joined with or without the side panels
installed.
TIP HAZARD
If multiple racks are used, joining cabinets provides limited stability to the
cabinets. Secure the cabinet to the oor before installing equipment.
Please follow these instructions very carefully. Failure to follow these
instructions can result in death, serious injury, or equipment damage.
WARNING
Enclosures within the same row can be connected together by using the included brackets.
Side panels can be removed for access between enclosures but is not necessary. There are two
connecting brackets on the front and two on the rear of each enclosure.
1. Align the enclosures that will be connected together.
2. Remove the enclosure doors.
NOTE: See the Remove Front and Rear Doors section for instructions.
3. Remove a connecting bracket, shown below. Align the connecting bracket between the
enclosures such that each end can screw into the other enclosure. Repeat this step for all
connecting brackets. Each pair of enclosures should be connected together by two front and
two rear brackets.
Page 8
Indice
Altri manuali Rocstor Rack e supporto

Rocstor
Rocstor R8108BLK Manuale utente

Rocstor
Rocstor Y10E023-B1 Manuale utente

Rocstor
Rocstor Y10E032-B1 Manuale utente

Rocstor
Rocstor R8106BLK Manuale utente

Rocstor
Rocstor Y10E031-B1 Manuale utente

Rocstor
Rocstor SolidRack 8U Manuale utente

Rocstor
Rocstor R8107BLK Manuale utente

Rocstor
Rocstor R8105BLK Manuale utente

Rocstor
Rocstor Rocmount ProM DRM Manuale utente

Rocstor
Rocstor Y10E026-B1 Manuale utente