Safeline TTR Manuale utente

www.safeline-group.com
12.2021 © 2021 SafeLine and all the SafeLine products and
accessories are copyrighted by law.
Communications system
SafeLine TTR v.2.2.0 EN
TTR manual
Innovation brought to you from Tyresö Sweden

2SafeLine TTR v.2.2.0 EN
Technical data
Power: Supply voltage: 230 VAC. Min: 3,9W , Max: 6,9W
Battery: Battery voltage: 12V. Lead battery.
Capacity: 0.8 Ah.
Charge: 13.7-13.9 V, max. 200 mA.
Communication: *TTR-GSM
- Supports 2G (900/1800 MHz)
*TTR-4G
- Supports 2G, 3G and 4G (800/900/1800/2100/2600 MHz)
Emergency light: Emergency light output: 12V max 0.5A.
Acoustic emergency signal output: 12 VDC max 0.5A.
Inputs: 10-30 Volts; 5 mA. Optically isolated.
Pictogram outputs: Max 200mA, 12VDC.
Size: 181,5 x 171,2 x 71 mm (L x W x H).
Weight: 1,5kg
This product is intended for use in EMEA countries.

3SafeLine TTR v.2.2.0 EN
Content Technical data 2
General information 4
Introduction 5
TTR Alarms 5
Component list 6
Installation 9
Mounting 9
Mounting interface boards 10
Wiring diagram, emergency bell and light 11
Wiring diagram, emergency bell and pictograms 12
Wiring diagram, emergency light and pictograms 13
Wiring diagram, extra station card 14
Wiring diagram PSTN Line (max 9 units) 14
Network services 15
Activating the SIM card 15
LED indication 16
Test procedure after installation 18
Conguration 19
Conguration overviews 19
Remote Cong. with telephone rst step 21
Remote Cong. with telephone second step 22
On-site conguration with telephone 23
Conguration example 24
Conguration codes table 25
Operation 30
Calling with SafeLine TTR 30
Intercom between machine room & car/pit/Top of car 31
Emergency calling process 32
Service 33
Battery function 33
Troubleshooting 34
Declaration of conformity 35

4SafeLine TTR v.2.2.0 EN
This unit was built with state-of-
the-art technology and to
generally recognised safety
related technical standards
currently applicable. These
installation instructions are
to be followed by all people
working with the unit, in both
installation and maintenance.
It is extremely important that
these installation instructions
are made available at all times
to the relevant technicians,
engineers or servicing and
maintenance personnel. The
basis prerequisite for safe
handling and trouble free
operation of this system is a
sound knowledge of the basic
and special safety regulations
concerning conveyor techno-
logy, and elevators in particular.
The unit may only be used for
its intended purpose. Note in
particular that, no unauthorised
changes or additions may be
made inside the unit or indivi-
dual components.
Exclusion of liability
The manufacturer is not liable
with respect to the buyer of
this product or to third parties
for damage, loss, costs or work
incurred as a result of accidents,
misuse of the product, incorrect
installation or illegal changes,
repairs or additions. Claims
under warranty are likewise
excluded in such cases. The
technical data is the latest
available. The manufacturer
accepts no liability arising from
printing errors, mistakes or
changes.
Declaration of conformity
Download ”The declaration of
conformity” at our website:
www.safeline-group.com
Safety Precautions!
- Only trained professionals,
who are authorised to work on
the equipment, should install
and con gure this product.
- This quality product is dedi-
cated for the lift industry. It has
been designed and manufactu-
red to be used for its speci ed
purpose only. If it is to be used
for any other purpose, SafeLine
must be contacted in advance.
- It should not be modi ed
or altered in any way, and
should only be installed and
con gured strictly following the
procedures described in this
manual.
- All applicable health and
safety requirements and
equipment standards should be
considered and strictly adhered
to when installing and con -
guring this product.
- After installation and con -
guration this product and the
operation of the equipment
should be fully tested to ensure
correct operation before the
equipment is returned to
normal use.
Electrical and electronic
products may contain materials,
parts and units that can be
dangerous for the environment
and human health. Please
inform yourself about the local
rules and disposal collection
system for electrical and
electronic products. The correct
disposal of your old product
will help to prevent negative
consequences for the environ-
ment and human health.
General
information

5SafeLine TTR v.2.2.0 EN
Introduction
General:
• Telephone in machineroom must be connected to the RJ12
jack on the front of the TTR unit.
• RJ12 jack next to the 14 pin connector is for the microphone,
alternatively microphone and external speaker (sold separa-
tely).
• The emergency button’s function (NO or NC) is set by the
jumpers on the TTR board (not autodetect).
• Install jumpers on the TTR board, so they stand as the unit
which is replaced (same jumper names).
• Remember to attach the unit, and tighten the screws in the lid
to avoid the device to “rattle”.
• The battery is disconnected at delivery and must be connected
when the TTR is installed.
If using emergency lights:
• To provide 1 hour of emergency lights, the TTR should not be
loaded with more than 3-5W (replace 10W halogen pin bulb
with a 5W bulb)
If using pictograms:
• Pictograms are active +12 V, ground (0V) is connected to
terminal input 7 (not terminal input 5)
• Remember to activate TTR’s relays as pictograms (* 88 * 1 #)
If using extra station under the car or in the shaft:
• There should be installed an extra board (SL3000-XRemBoard).
Please read the following
information, as it contains
important information
about differences between
TTR and other emergen-
cy-alarm telephones.
TTR Alarms

6
1 2 3a 3b 3c 4
7
9 8
5
11
6
10
SafeLine TTR v.2.2.0 EN
Component list

7SafeLine TTR v.2.2.0 EN
1. ConnectorRJ12foroptionaltelephonehandset
For programming and intercom communication. Can also
be used for external calls. Any standard analogue tone dial
telephone can be connected.
2. Reset button
• Reset all alarms.
• Terminates a phone call in progress.
• Triggers manual battery check
• Activates display of GSM signal quality.
3. LED indicators
3a Mains power
3b Active alarm / Battery status
3c PSTN / GSM Net / Call status
4. RS232PCconnection
For rmware update and conguration.
5. Slot for optional extra station card
Two supplementary microphone/speaker units can be
connected for the car roof and/or in the lift pit. When the
station’s alarm button is pressed for the set delay time, an emer-
gency call is emitted. The recorded message can be different
for each unit.
6. Jumpers for emergency button
Selects NO/NC for the emergency button
7. Jumpers for pictogram, emergency light and sounder
The outputs from the SafeLine TTR can be congured by use of
the jumpers J8 and J9 to activate pictograms emergency light
and sounder switch.
8. Terminals
9. Microphone input
10.Volume control
For loudspeaker in car. Turn right to increase the volume.
11.Slot for PSTN or GSM card
Component list

8
6
2
3
5
4
1
SafeLine TTR v.2.2.0 EN
Extra station card
PSTN card GSM/4G card
GSM Antenna
1. TerminalorRJ12connectorforPSTNline.
Internal connection of PSTN line.
2. GSM antenna connection, SMA
3. SIM-card holder
4. Volume controls
For the extra remotes. Turn right to increase the volume.
5. Terminals
For the extra remotes.
6. GSM antenna
Component list

9
>>1.5 m >>1.5 m
>>1.5 m
0,1m²
SafeLine TTR v.2.2.0 EN
Installation
Unplug the main power and battery before performing any
changes. To avoid GSM interference: Place the main unit, the
stations and the GSM antenna more than 1.5 meters apart.
Mounting

10
GSM/4G
PSTN
SafeLine TTR v.2.2.0 EN
Mounting
interface
boards
or
Extra station card
Altri manuali per TTR
2
Indice
Altri manuali Safeline Sistema di sicurezza
Manuali Sistema di sicurezza popolari di altre marche

EDM
EDM Solution 6+6 Wireless-AE Manuale utente

Highway Safety Group
Highway Safety Group EA401 Manuale utente

Siren
Siren LED GSM Manuale utente

Detection Systems
Detection Systems 7090i Istruzioni per il montaggio

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Manuale utente

Siemens
Siemens FDM273 Manuale utente