Salus SP220 Manuale utente

Instruction Manual
Dual Channel Controller
Dual Channel Controller
Model No SP220
2
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 1

SP220 INSTRUCTION MANUAL2
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 2

PRODUCT COMPLIANCE
This product complies with the essential requirements of the following EC Directives:
•Electro-Magnetic Compatibility Directive 2004/108/EC
•Low Voltage Directive 2006/95/EEC
•EC Marking directive 93/68/EEC
SAFETY INFORMATION
These instructions are applicable to the Salus Controls model stated on the front cover of this manual
only, and must not be used with any other make or model.
These instructions are intended to apply in the United Kingdom only, and should be followed along
with any other statutory obligations - if you are in any doubt, please contact the Salus Controls
technical helpline.
This accessory must be fitted by a Competent person, and installation must comply with the
guidance provided in the current editions of BS7671 (IEE Wiring Regulations) and Part ‘P’ of the
Building Regulations. Failure to comply with the requirements of these publications could lead to
prosecution.
Always isolate the AC Mains supply before opening
or removing the unit from the wall or wall box.
Please leave these instructions with the end user where they
should be kept in a safe place for future reference.
3SP220 INSTRUCTION MANUAL
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 3

INTRODUCTION
A heating controller is used to switch the heating
system in your home on and off as needed. It works by
controlling the heating boiler according to a series of
programmed settings that take effect at different times
of the day.
The SP220 from Salus Controls is a stylish and accurate
twin channel programmable heating controller
designed for independent control of central heating
and hot water. Fitted with a large, easy to read Liquid
Crystal Display (LCD), this controller has been
specifically designed to be used for 230V AC heating
applications.
The use of the revolutionary Touch Ring technology makes for simple usage, and is coupled with
a unique, smart design and the ‘one touch’ operation makes the SP220 easy to operate.
FEATURES
• Touch Ring Technology
• Large LCD with white backlight
• Stylish Casing
• Radio Controlled Clock (RCC)
• Manual Time and date Setting Option
• Advance +1Hr function (maximum 9 hours)
• Holiday Function
• Service Function
• Three On/Off Periods each day
• Built in Start-up Programmes
SP220 INSTRUCTION MANUAL4
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 4

INSTALLATION
Please read the important safety information at the start of this manual before you begin to install
the device. The ideal position to locate the SP220 programmable heating controller is about 1.5m
above floor level. It should be mounted in a location where the controller is easily accessible,
reasonably lit and free from extremes of temperature and draughts. Do not mount the controller on
an outside wall, above a radiator or in a location where it may be subjected to direct sunlight.
The SP220 should be mounted in a location where it will not come into contact with moisture or
condensation, as this can affect the Touch Ring operation.
To ensure trouble free reception for both the Radio Controlled Clock (RCC) and the Radio Frequency
(RF) signal, always ensure that the programmable thermostat is mounted away from any possible
sources of interference (such as radios, TV sets, computers, etc.), and is not mounted on or in close
proximity to large metal objects. Installing the SP220 in enclosed areas such as cellars and basements
is not recommended.
The electrical connections to the SP220 are made to the terminal strip within the controller itself.
Connection details are shown below - no Earth connection is required for the correct and safe
operation of the SP220.
230V AC Connections
Terminal Description Terminals
4 Central Heating On
3 Hot Water On
2 Central Heating Off
1 Hot Water Off
L Mains Live
N Mains Neutral
5SP220 INSTRUCTION MANUAL
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 5

After installing the controller in a suitable location, wiring connections can be made as shown above.
The following criteria apply to the installation:
• The incoming AC mains supply should be 230V AC and fused at 6 Amps.
• Optimum cable size for installation is 1.5 mm2; wiring colours should be in accordance
with the current requirements of the IEE Wiring Regulations.
• Cable entry should be made at the cable entry point
• All wiring connections should be securely made, and be firmly gripped beneath the terminal clamp.
Do not restore the mains supply to the system until all associated items are fully installed.
NOTE: All electrical installation work should be carried out by a suitably qualified Electrician or other
competent person. If you are not sure how to install this controller consult either with a qualified
Electrician, Heating Engineer or your boiler / heating system supplier for advice on how to continue.
Do not remove or refit the SP220 without the mains supply to the system being isolated.
AFTER INSTALLATION
After completing installation and powering up the SP220 for the first time the controller will behave
in the following way:
All the indicators on the display and the backlight will be turned on for a few seconds. The internal
firmware version will then be displayed for a few seconds, and the SP220 will then operate in Normal
mode (controller output OFF).
If the Reset Button is pressed, the SP220 will behave in the
same way as described above and any previously saved user
settings will be deleted and overwritten with the default
settings, except when the SP220 is in SERVICE mode.
SP220 INSTRUCTION MANUAL6
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 6

USER INTERFACE AND CONTROLS
The status and operation of the SP220 can be clearly seen on the large
backlit Liquid Crystal Display (LCD) - this display allows the user to see
at a glance the current status of the heating system.
The display consists of a combination of symbols and alphanumeric
displays. The top row displays status indicators, the centre row is a time
and day of the week indicator and the bottom row is an alphanumeric
display for menu and status messages.
The status indicator symbols and their meanings are shown in the following table:
Indicator Description Function
Clock Display Displays the day and time
Alphanumeric Display Displays menu and other status messages
Hot Water indicator Indicates Hot Water system is turned on
Central Heating indicator Indicates Central Heating system is turned on
ON
Mode indicator Indicates Continuously On
ONCE
Mode indicator Indicates output is turned on for one period per
day, from PROGRAM 1 ON to PROGRAM 3 OFF
AUTO
Program Mode indicator Indicates Auto ON or Auto OFF
programme is running
OFF
Mode indicator Indicates Continuously Off
RCC indicator Indicates the status of the Radio Controlled Clock
Holiday indicator Indicates Holiday operation mode is selected
Touch Lock indicator Indicates Touch Lock is activated
Service indicator Indicates Service function is active
7SP220 INSTRUCTION MANUAL
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 7

USER CONTROL FUNCTION SUMMARY:
Key / Operation Functions
Touch Ring (move clockwise) Increases the selected setting and scrolls
down the menu selection
Touch Ring (move anti- clockwise) Decreases the selected setting and scrolls
up the menu selection
OK Key Enters Menu or confirms a menu selection
Arrow (Back) Key Single press goes back to the previous screen
or previous option selected. Press and hold for
2 seconds to return to NORMAL mode
Reset Button Resets the controller to default (original factory)
settings, except when in SERVICE mode.
Slide Switch Activates and deactivates the key lock function
(prevents accidental changes)
There are few user controls for the
SP220, making the controller very
easy to operate. The controls are a
Touch Ring (which surrounds the
user display), two touch sensitive
buttons, a reset button and a slide
operated switch mounted on the
side of the controller.
These controls are shown below,
along with a description of each of
their functions.
SP220 INSTRUCTION MANUAL8
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 8

OPERATION
The SP220 is configured and adjusted by the use of an
innovative and stylish Touch Ring, and two touch
sensitive buttons. The Touch Ring surrounds the
controller display, and is operated very easily by moving
your finger around the ring.
ACCESSING THE MENUS
The Arrow key is not active when
the SP220 is in NORMAL mode. To
access the Menu screens, press the
OK key twice and backlight is now
ON. The first menu displayed is the
BOOST menu. Use the Touch Ring
to scroll through the Menus, and
press the OK key to select the
menu you want to use:
You can scroll through the menus in either direction (forwards or backwards) depending on the
direction you move your finger around the Touch Ring. The menus are displayed in the order
shown in the picture above.
Pressing the Arrow key will return the SP220 to NORMAL mode. The controller will also return
to NORMAL mode after 10 seconds if no Key is pressed or if no movement is detected on the
Touch Ring.
9SP220 INSTRUCTION MANUAL
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 9

BOOST MENU
The BOOST menu allows the use of a temporary override mode which allows the user to override the
current programme settings and turn the heating and/or hot water on for a preset period. This mode
is activated by selecting the BOOST menu – this mode allows you to override the current programme
settings up to a maximum of 9 hours. The options available will differ slightly depending on whether
the controller is set for pumped (P) or gravity (G) operation.
Pumped Operation:
Central Heating Hot Water
c0 Heating override OFF h0 Hot Water override OFF
c1 – c9 Heating override active h1 – h9 Hot Water override active
for selected period for selected period
If the controller is set for Pumped operation, then central heating and hot water override settings
can be set independently.
Scroll through the setting by using the Touch Ring. Changing the settings will increase the duration
of the override by one hour, to a maximum duration of nine hours. Increasing the setting beyond this
level will roll the setting back to 0 and disable the temporary override. Confirm the heating setting
by pressing the OK key, and then change the hot water setting in the same way.
SP220 INSTRUCTION MANUAL10
SP220 Manual Ver 005.qxd:Layout 1 5/1/11 10:54 Page 10
Indice
Altri manuali Salus Controllori

Salus
Salus THB23030 Manuale utente

Salus
Salus WT100 Scheda tecnica

Salus
Salus PC16F Manuale utente

Salus
Salus TRV10RFM Manuale utente

Salus
Salus PC15V3 Manuale utente

Salus
Salus TRV10RFM-3 Manuale utente

Salus
Salus RX10RF Manuale utente

Salus
Salus TRV10RFM Manuale utente

Salus
Salus KL04NSB Manuale utente

Salus
Salus PC12HW Manuale utente

Salus
Salus PC11 Manuale utente

Salus
Salus SC102ZB Manuale utente

Salus
Salus PC11W Manuale utente

Salus
Salus PC12HW Manuale utente

Salus
Salus AKL04P Manuale utente

Salus
Salus PCSol 201 Manuale utente

Salus
Salus PC11W Manuale utente

Salus
Salus THB23030 Manuale utente

Salus
Salus AKL06P Manuale utente

Salus
Salus EP210 Manuale utente