Saunum BASE Manuale operativo

Sauna climate unit
Saunum BASE / BASE Short / BASE S
ENG
INSTRUCTIONS FOR USE AND INSTALLATION

3
ENG
Saunum Saunas OÜ
congratulates you
on choosing an innovative
sauna climate unit!
TABLE OF CONTENTS
Safety information ___________________________________
INSTALLATION INSTRUCTIONS
Installation _________________________________________
Dimensions of the Saunum BASE / BASE Short models_________
Saunum BASE / BASE Short model installation distances_______
Components of the Saunum BASE / BASE Short device ________
Saunum BASE S model dimensions_______________________
Saunum BASE S model installation distances________________
Electrical connections _________________________________
INSTRUCTIONS FOR USE
Instructions for use __________________________________
Sauna climate control _________________________________
Using the device _____________________________________
Instructions for using himalayan salt balls __________________
Warnings __________________________________________
Maintenance and repair________________________________
Warranty __________________________________________
Installation report _____________________________________
4
6
7
8
9
14
16
20
24
24
24
25
26
27
28
29
TABLE OF CONTENTS

4 5
ENG ENG
These installation and operating instruc-
tions are intended for the owner or main-
tenance provider of the sauna, as well as
the electrician responsible for installing
the sauna climate unit. After installing the
sauna climate unit, the manual must be
handed over to the owner or the main-
tenance provider. Before using Saunum’s
BASE, BASE Short or BASE S sauna climate
unit, please read the installation and safety
instructions.
The BASE / BASE Short / BASE S sauna
steam room climate unit manufactured by
Saunum Saunas OÜ (hereinafter the De-
vice) may not be taken into use before read-
ing the installation and safety instructions!
The Device is designed for mixing layers
of air in the steam room of the sauna and,
harmonizing the temperatures of the in-
door climate of the sauna and, as an added
function, releasing salt ions into the indoor
air from the Himalayan salt balls included
in the set. The special ventilator in the De-
vice generates air ow that harmonizes the
upper and lower air layers of dierent tem-
peratures in the heated sauna and makes
the steam smooth and even.
NB! It is forbidden to use the sauna
climate unit with the heater above 194
°F if the ceiling is not made of non-
combustible material or if there is no
ceiling protection screen above the
heater!
NB! Do not use the Device for anything
other than the intended purpose!
Make sure you do not have allergies and
contraindications to a saline environment.
Consult a doctor about medical contraindi-
cations.
Saunum Saunas OÜ will not be held liable
for various side eects to the health of the
user of the Device. Using Himalayan salt
balls in the Device is an optional added
function which may be left unused without
any eect on the functioning of the Device
in harmonizing the climate of the steam
room.
In the case of any health concerns, the salt
balls can be removed from the base tray
and the Device can be used for only mixing
the layers of air.
CAUTION! The sauna climate unit may
only be activated for the duration of the
steam bath. The sauna climate unit must be
switched o when heating the sauna and
during breaks between steam baths!
Do not pour water into the housing or ven-
tilation openings of the Device or use the
SAFETY INFORMATION
Device in a room where there is water ow-
ing on the oor or where ammable/explo-
sive gases may leak into the air.
The Device may not be used if any hous-
ing components have been removed and/
or the electrical wiring diagram has been
altered. Children must not be allowed
access to the Device or to play with the
Device. Children may not clean the Device.
The Device must be installed by a person
who is qualied to perform electrical
work. The Device must be connected to
the power grid by using permanent wiring
that is suitable for the ambient tempera-
ture conditions. The connecting terminals
of the Device must be equipped with pro-
tective earthing (PE). The cross-sectional
area of the wire must be at least 1.5 mm2.
The Device must be powered from a power
circuit that is protected with overcurrent
and residual-current devices. Supply volt-
age: 230 V 50/60 Hz Wattage: 75 W.
CAUTION! Before servicing and cleaning
the Device, unplug the Device and wait for
the moving parts of the Device to come to
a complete stop.
CAUTION! The Device housing has sharp
corners and edges against which you may
injure yourself if you are not careful.
SAFETY INFORMATION
CAUTION! The sauna climate unit must be
installed so that the exhaust opening is not
directed towards the heater.
TRANSPORT
AND STORAGE
The Device is packaged by the manufac-
turer in a way that ensures the preservation
of the Device under normal transport condi-
tions. The Device must not be dropped,
tossed or stored under heavy goods. Store
the Device in a dry room that is protected
from weather eects.

6 7
ENG ENG
INSTALLATION INSTRUCTIONS
INSTALLATION
NB! Read the Safety Information before
beginning installation (see pp 4–5)!
The Device is installed on the wall of the
steam room or behind the inner lining (if
the device is integrated into the wall, the
lining boards must be secured to the sheet
metal face of the air duct with weather-
board clamps) (see Figures 1, 1A, 1B, 1C, 1D,
1E and 2, 2A, 2B, 2C and 2D on the following
pages).
The air outlet of may not be obstructed and
sauna users must keep their feet at least 20
in away from the fan.
The discharged air ow must be able to
spread freely throughout the steam room.
Figure 1
Dimensions of the Saunum
BASE / BASE Short models.
SIDE VIEW
FRONT VIEW REAR VIEW
DIMENSIONS OF THE DEVICE
5.5 in
1 in
4.2 in
8.9 in
15.7 in
BASE 84.9 in; BASE Short 74.8 in
BASE 69 in; BASE Short 58.0 in
17.2 in
4.4 in
39.4 in29.3 in
11.8 in
9.8 in
0.3 in
BOTTOM VIEW
7,9 in
0,5 in
Cable opening

8 9
ENG ENG
Figure 1A - Saunum BASE / BASE Short model installation distances.
DEVICE WALL MOUNTED INSIDE OF WALL
Figure 1B - Saunum BASE / BASE Short model installation distances.
WALL-MOUNTED DEVICE
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
0.5 in distance
from the wall
7.8 in distance
from the wall
CEILING
FLOOR
Safe distance based
on the manufacturer’s
recommendations
4 in minimum distance from the oor
4.1 in
FLOOR
WALL
0.5 in distance
from the wall
7.8 in distance
from the wall
CEILING
FLOOR
4 in minimum distance from the oor
Safe distance based
on the manufacturer’s
recommendations
Safe distance based
on the manufacturer’s
recommendations
Safe distance based
on the manufacturer’s
recommendations

10 11
ENG ENG
Figure 1C - Components of the Saunum BASE / BASE Short device. The Device works most eciently when the
edge of the upper airing vent opening is
adjacent to the ceiling of the steam room
(model with a protective grille). If the De-
vice is not equipped with a protective grille,
the Device should be installed so that the
upper edge remains 3–4 in below the ceil-
ing. The lower edge may not be closer than
4 in to the oor to prevent the water on the
oor from coming into contact with the
electrical wiring of the Device.
The Device is designed for wall mounting
using the hanging strips included in the
set. The wall in the installation spot must
COMPONENTS OF THE DEVICE
ADDITIONAL AIR VALVE
BOTTOM
TRAY
SALT BALLS
SWITCH
AIR DISCHARGE AND GRILLE
GRILLE MOUNTING
BOLT
GLASS FRONT PANEL
be able to carry the weight of at least 77
lb and allow the supplied hanging strips to
be fastened with screws. The hanging strips
are attached to the wall of the steam room,
each with at least two screws. The Device is
then lifted onto the wall so that both the
upper and lower strips slide between the
strips attached to the back of the Device.
Figure 1D - Saunum BASE / BASE Short
model installation.
INSTALLATION INSTRUCTIONS

12 13
ENG ENG
Figure 1E - Recommended instal-
lation of the Saunum BASE / BASE
Short model using a hanging strip.
1. Install the strips supplied with the
Device on the wall. Use anchors if
necessary.
2. Hang the Device on the wall-mounted
strips. Make sure that the eyelets on
the back of the Device rest equally on
both slats. (If necessary, use a spirit
level to ensure that the Device is level.)
3. Check the Device for any external
damage. It is forbidden to use a dam-
aged Device!
4. Install the salt balls. The salt balls are
placed in the Device after it has been
mounted on the wall. To install the balls,
open the lower grille by removing the
two hand-turned bolts. Place the balls in
their slots on the tray.
SALT BALLS
FASTENING BOLT TO REMOVE
COVER GRID
HANGING STRIP
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Screws (min 2 pcs)
1000 mm33 in MIN distance from the oor

14 15
ENG ENG
SIDE VIEW
BOTTOM VIEW
FRONT VIEW REAR VIEW
Figure 2
Saunum BASE S model dimensions.
DIMENSIONS OF THE DEVICE
DIMENSIONS OF THE DEVICE
According to the ceiling height
4.4 -6.9 in
8.9 in
4.5 in
45.3 - 74.4 in
66.5 - 90.6 in
16.7 in
29.3 in
0.3 in
11.8 in
9.8 in
7,9 in
0,5 in
Cable opening

16 17
ENG ENG
DEVICE WALL MOUNTED INSIDE OF WALL
Figure 2A - Saunum BASE S model installation distances. Figure 2B - Components of the Saunum BASE S model device.
COMPONENTS OF THE DEVICE
SALT BALLS
ADDITIONAL AIR DAMPER
BOTTOM
TRAY
SWITCH
HANGING STRIP
SHEET METAL FRONT PANEL
GRILLE
INSTALLATION INSTRUCTIONS
0.6 in distance
from the wall
7.9 in distance
from the wall
CEILING
FLOOR
4 in minimum distance from the oor
1.9 in
FLOORWALL
Safe distance based
on the manufacturer’s
recommendations
Safe distance based
on the manufacturer’s
recommendations

18 19
ENG ENG
Figure 2C - Recommended instal-
lation of the Saunum BASE S model
using a hanging strip.
1. Install the strips supplied with the
Device on the wall. Use anchors if
necessary.
2. Hang the Device on the wall-mounted
strips. Make sure that the eyelets on
the back of the Device rest equally on
both slats. (If necessary, use a spirit
level to ensure that the Device is level.)
3. Check the Device for any external
damage. It is forbidden to use a dam-
aged Device!
4. Before using the Device, cover all un-
covered openings using the specied
aluminum tape to do so.
5. Place the salt balls. The salt balls are
placed in the Device after it has been
mounted on the wall. To place the balls,
open the lower grille by removing the
two hand-turned bolts. Place the balls in
their slots on the tray.
HANGING STRIP
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
Adjust the sides
and top of the cap
Opening under the cap after
adjusting the telescopic cap
Screws (min 2 pcs)
Based on the height of the room!33 in MIN distance from the oor
Fastening bolt to
remove the grille
Salt balls
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Saunum Stufa
Manuali Stufa popolari di altre marche

Empire Heating Systems
Empire Heating Systems WCC65 Manuale utente

Wetekom
Wetekom 92 86 43 Manuale utente

Desa
Desa SPC170-F Manuale utente

Watlow
Watlow Watrod Electric Tubular Heaters Manuale utente

Haverland
Haverland ECO-DRY GPS Series Manuale elenco delle parti

Stelpro