Scan View ScanmateF8+ Manuale utente


ScanMate F6 / ScanMate F8 Plus • Operator’s Manual
© March, 1998 ScanView. All rights reserved.
No part of this publication may be copied or in any other way
reproduced, nor may it be stored in a retrieval system, without
the prior written permission of ScanView A/S.
The information in this manual is subject to change without
notice. ScanView A/S assumes no responsibility or liability for
any errors or inaccuracies that may appear in this book.
ScanMate F6, ScanMate F8 Plus, LightView, EasyMount,
ColorTrio, ColorQuartet and ColorQuartet MouseFree are
trademarks of ScanView A/S.
Other manufacturers’ trademarks are used in an editorial
fashion with no intention of infringement.
Head office U.S. Subsidiary
ScanView A/S ScanView, Inc.
Meterbuen 6 1875 South Grant St., Suite 750
DK-2740 Skovlunde San Mateo, CA 94402
Denmark U.S.A.
Tel: (+45) 44 53 61 00 Tel: (+1) 650-378-6360
Fax: (+45) 44 53 61 08 Fax: (+1) 650-378-6368
This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment
is operated in a commercial environment.
This equipment is supplied with a shielded cable. It must
be operated with a shielded cable in order to meet FCC Class A
emission limits.
This equipment generates and can radiate radio frequency
energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential
area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his own
expense.
Manual edition: 4 PN 730-00-036-04
Software versions:
ColorTrio for Macintosh: V 2.0
ColorTrio for PC: V 2.0

CONTENTS
ScanMate F6 / ScanMate F8 Plus • Operator’s Manual i
Welcome to the ScanMate F6 and ScanMate F8 Plus..............................iii
1 • Specifications
Technical specifications................................................................1•1
Environmental specifications ......................................................1•3
Dimensions....................................................................................1•3
2 • Installation
Computer requirements ..............................................................2•1
Environmental requirements ......................................................2•1
Unpacking the scanner ................................................................2•2
Cable connections ........................................................................2•2
Mains connection ..............................................................2•2
SCSI connection: General rules ........................................2•2
Single-unit SCSI connection..............................................2•3
Multiple-unit SCSI connection..........................................2•3
SCSI connection troubleshooting ....................................2•5
Calibrating the scanner ................................................................2•5
3 • General operating procedures
Monitor set-up ..............................................................................3•1
Conditions for viewing originals and prints................................3•1
Calibration ....................................................................................3•1
4 • Handling originals and mounting plates
The mounting plate ......................................................................4•1
Using the mounting plate ..................................................4•1
Mounting originals directly on the mounting plate ........4•2
Cleaning the mounting plate ............................................4•3
Standard templates ......................................................................4•3
Mounting originals in a template......................................4•3
Mounting a template in the scanner ................................4•4
Template numbers ............................................................4•5
Optional DustFree™ magnetic templates ..................................4•5
Scanning color negatives..............................................................4•6
Scanning reflective originals ........................................................4•6
Avoiding Newton rings in transmission scans ............................4•6
Avoiding dust ................................................................................4•7

The built-in LightView™ light table (ScanMate F8 Plus) ..........4•8
The optional EasyMount™ mounting table ..............................4•8
5 • Maintenance
Replacing the fuse ........................................................................5•1
Replacing the lamps......................................................................5•2
Replacing the viewing lamps and reflection lamps ........5•2
Replacing the transmission lamp......................................5•2
Checking the alignment of the transmission lamp ........................5•4
Adjusting the alignment of the transmission lamp ....................5•5
Replacing the air filters ................................................................5•6
Preparing the scanner for shipping ............................................5•6
6 • Troubleshooting
Computer refuses to start ............................................................6•1
Hard disk not accessible ..............................................................6•2
Screen freezes ................................................................................6•2
Scanner tray does not move ........................................................6•2
Scanner freezes when asked to do a reflection scan ..................6•3
Scanning light does not come on ................................................6•3
Light table does not light up (ScanMate F8 Plus) ......................6•3
Scanner cannot be white-point calibrated ................................6•4
Scanner cannot be focus calibrated ............................................6•4
"ERROR” lamp is constantly lit ....................................................6•5
“ERROR” lamp flashes ..................................................................6•5
“READY” lamp does not light up..................................................6•5
Contents
ii ScanMate F6 / ScanMate F8 Plus • Operator’s Manual

The ScanMate F6 and ScanMate F8 Plus are fast single-pass A3 flatbed
scanners with a vertically aligned optical system. They are designed to extract
digital RGB color from transmission and reflection originals, including both
positives and negatives, using the supplied scanning program, ColorTrio. Black
and white originals can be scanned as gray scale or line art.
The ScanMate F6 and ScanMate F8 Plus can scan reflective originals up
to European A3 format (297 x 420 mm or 11.7" x 17"). Maximum optical
resolution is 3000 dpi for the ScanMate F6 and 4000 dpi for the ScanMate F8
Plus. For both models, maximum interpolated resolution is 11,000 dpi.
After scanning, CMYK separations can be made via Photoshop or other
separation software. ScanView’s ColorQuartet software is available as an
option and is highly recommended for both scanning and separation.
In order to get the full benefit from your scanner, we strongly recommend
that you read this manual, as well as the ColorTrio Operator’s Manual. For
installation or repacking, please refer to the ScanMate F6 / ScanMate F8
Plus Installation and Repacking Instructions. In the manuals you will find:
ScanMate F6 / ScanMate F8 Plus manual ColorTrio manual
• specifications • how to install the software
• installation requirements and electrical • how to calibrate the scanner
connections • how to scan images with ColorTrio
• general operating procedures • basic color reproduction concepts
• scanning procedures
• maintenance
• troubleshooting
The manuals assume that you have a basic working knowledge of your Macintosh
or of your PC, including Windows 95 or Windows NT. If you are in doubt about
general operating procedures, please consult the manuals supplied with your
computer.
PLEASE NOTE
This manual is valid for scanner types 0322 and 0340.
If your scanner has another type number, please obtain the
appropriate manual from your local ScanView dealer.
WELCOME TO THE SCANMATE F6 & SCANMATE F8 PLUS
ScanMate F6 / ScanMate F8 Plus • Operator’s Manual iii

Specifications
1•0 ScanMate F6 / ScanMate F8 Plus • Operator’s Manual

Technical specifications
Originals
Transmission and reflection originals in positive or negative, color, gray
scale or line art, with or without existing screen.
Scanning technology
CCD flatbed with zoom lens.
Scanning area
Transparencies: 210 x 420 mm (8.3" x 17").
Reflectives: 297 x 420 mm (11.7" x 17").
Speed
Single-pass scanning.
ScanMate F6: up to 300,000 pixels per second.
ScanMate F8 Plus: up to 600,000 pixels per second.
Scan resolution
ScanMate F6: optical up to 3000 dpi, interpolated up to 9000 dpi.
ScanMate F8 Plus: optical up to 4000 dpi, interpolated up to 11,000 dpi.
Optical density
Range: 3.7, max:: 4.0.
Sensor unit
Trilinear CCD element, 8000 pixels wide.
Color resolution
3 x 16 bits
Focus
Automatic or user-adjustable via software.
Light source
Fluorescent lamp.
SPECIFICATIONS
ScanMate F6 / ScanMate F8 Plus • Operator’s Manual 1•1

Data platform
Power Macintosh
or IBM-compatible PC with Windows 95 or Windows NT 3.5.1 or higher.
Interface
Standard SCSI to Macintosh or PC.
Driver software
ColorTrio™ for Macintosh and PC.
Batch scanning
Included.
Options
ColorQuartet™ software for expanded scanning facilities, color
separation, ICC compatibility and photolab applications.
ColorQuartet MouseFree™ software for fully automated scanning.
ScanDot™ software for rescanning screened films (ScanMate F8 Plus only).
Additional mounting plates and templates.
DustFree™ magnetic templates for glass-free mounting.
EasyMount™ external mounting table.
Output formats
TIFF RGB. With ColorQuartet, also TIFF CMYK/Lab/RGB 16-bit/Gray
scale/Gray scale 16-bit/Line art; EPS RGB/CMYK/Gray scale/Line art;
PostScript (DCS) CMYK; JPEG RGB/CMYK/Gray scale; Targa; Scitex CT.
Power consumption
250 W.
Power supply
50-60 Hz, 100-240 VAC.
Fuse
T-4A high breaking capacity
Weight
50 kg (110 lbs).
Specifications
1•2 ScanMate F6 / ScanMate F8 Plus • Operator’s Manual

Environmental specifications
Operating temperature
Permissible range: 16 - 40°C (60 - 104°F)
Recommended range: 16 - 25° (60 - 77°F)
Storage temperature
–10 - 75°C (14 - 167°F)
Humidity
5 - 95% (non-condensing)
Air quality
The scanner should be operated in a smoke-free environment. Smoking
creates nicotine residues that will adversely affect scanner performance.
Dimensions
Width
940 mm (37")
Height
980 mm (38.6")
Depth
630 mm (24.8")
Specifications
ScanMate F6 / ScanMate F8 Plus • Operator’s Manual 1•3

Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Scan View Scanner