Schreder SHUFFLE POLE Manuale utente

SHUFFLE POLE
The components contained in these modules shall only be replaced by the manufacturer
or his service agent or a similar qualified person.
Always switch off the power prior to installa�on, maintenance or repair ac�vi�es.
A
Installation Instructions
HEIGHT WEIGHT
6460 21.2 118 260
6270 20.6 115 254
6080 19.9 111 245
5890 19.3 108 238
5700 18.7 104 229
5510 18.1 100 220
5320 17.5 97 214
5130 16.8 93 205
4940 16.2 89 196
4750 15.6 86 190
4560 15 82 181
4370 14.3 79 174
4180 13.7 75 165
3990 13.1 72 159
3800 12.5 68 150
3610 11.8 65 143
3420 11.2 61 134
3230 10.6 58 128
3040 10 54 119
2850 9.4 50 110
2660 8.7 47 104
2470 8.1 43 95
2280 7.5 40 88
mm ft kg lb
6840 22.4 125 276
6650 21.8 121 267
00-63-030 | DOC-0016143 Rev C | 11-2019 1/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
FLANGE PLATE
6
4
27
193mm / 7.6in
400mm | 15.75in
300mm | 11.8in
170mm
6.69in
27mm
1.06in
52mm
2.04in
Pole
Christmas
socket
Anchor Bolts
8x
Nuts
Washers Plate Guide
Pole Flange
Power
sockets
Key Lock
System
Tools not supplied
1 x M8 SCR Tri
Head DIN 22424 C
KEY
400mm
15.8in
M18
4X Anchor Bolt
8x M18 Nuts
8x 18mm Washers
GENERAL DIMENSIONS
Depending on the version
Tool is delivered with the pole.

B1a C1 - 1 DOOR
mains door
500mm
19.7in
666mm
26.2in
145mm
5.7in
1c C3 - 2 OPPOSITE DOORS
mains door
multipurpose door
400mm
15.7in
706mm
27.8in
446mm
17.6in 1050mm
41.3in
1b
mains door
beyond
light door
C2 - 2 DOORS
TYPES OF POLES
00-63-030 | DOC-0016143 Rev C | 11-2019 2/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
- EV charger
- Intercom
- Door without cut out
- Door with cut out
(Power Sockets)
500mm
19.7in
666mm
26.2in
666mm
26.2in
145mm
5.7in
200mm
7.9in
193mm
7.6in
193mm
7.6in
145mm
5.7in
145mm
5.7in
193mm
7.6in

1e
3/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
C5 - SIDE CABINET
1d
mains door
multipurpose door
beyond light door
1960mm
77.2in
C4 - 3 DOORS
00-63-030 | DOC-0016143 Rev C | 11-2019
TYPES OF POLES
mains door
access door
- Door without
cut out
- EV charger
- Intercom
- Door with
cut out
(Power Sockets)
145mm
5.7in
145mm
5.7in
145mm
5.7in
666mm
26.2in
193mm
7.6in
706mm
27.8in
1050mm
41.3in
400mm
15.7in
446mm
17.6in
666mm
26.2in
193mm
7.6in
145mm
5.7in
145mm
5.7in
450mm
17.7in
1250mm
49.2in
150mm
5.9in
65mm
2.6in
80mm
3.2in

4/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
00-63-030 | DOC-0016143 Rev C | 11-2019
TYPES OF DOORS
MAINS
DOOR
CHRISTMAS
DOOR
MULTIPURPOSE
DOOR
DOOR LOCKING SYSTEM
BEYOND LIGHT
DOOR
Triangular
Head Screw
Inner Hexagonal
Head Screw Key Lock
KEY LOCKING SYSTEM
Unlocked - Open Locked -Closed
C

1 2a
2b
5/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
Foresee the number and dimension
for flexible empty pipe.
Fill the moulding with concrete C16/20 (B20). After concrete curing, remove jig.
34
Using the supplied jig, place the anchor bolts inside
the concrete moulding leaving threaded extremity out.
The extremity depends on the type of installation and
how the finishing is done.
It should have enough space for M18 nuts, washers and tool for tightening.
The anchor bolts are delivered along with the pole (flange plate version).
80-100mm
3.2-3.9in
00-63-030 | DOC-0016143 Rev C | 11-2019
FLANGE PLATE MOUNTING
D
400mm
15.8in

00-63-030 | DOC-0016143 Rev C | 11 -2019 6/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
4 x M18
172 N.m
126.9 lb.ft
+1
-0
27
Put in place the column, guiding the
electrical cables to the compartment base.
Fully tighten the nuts following the recommended
torque values.
Check the correct vertical alignment of the pole.
Assemble the top washer and nut. Check and if
necessary correct, the column’s verticality by turning
the leveling nuts, underneath the flange plate.
M18 Nut
Washer
Washer
Flange Plate
M18 Nut
Used for leveling pole
M18 Anchor Bolt
Concrete
Place a levelling nut, plus washer, on each bolt.
5
78
Pole should be oriented in a way that performing
any kind of maintenance is easy and safe.
6
FLANGE PLATE MOUNTING
+0.7
-0

7/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
Open the foundation shaft and drainage
according to column’s planting depth.
The calculation is based on the hole into which the lighting column is planted being
back-filled with the excavated material or material of better quality. The following should
be specified to the installer:
a) all back-filling material is to be placed in 150 mm thick layers and be well compacted;
b) during compaction, care is to be taken to ensure that the corrosion protection system
of the lighting column is not damaged;
c) when the hole is back-filled with concrete, the concrete is to extend from the base of the
lighting column to ground level;
d) where paving or bituminous surfacing is to be applied around the lighting column, the top
level of the concrete may be lowered by the thickness of this surfacing;
e) a duct with the same dimensions as the lighting column's cable entry slot is to be formed in
the concrete using a suitable preformed lining tube.
Foresee the electrical cable ditch where the
flexible pipe is mounted.
Leave typically at 0.5m below ground level.
Put the column in place guiding the
underground electrical cables through
the pipe until they reach the base compartment
and the column is at the right depth.
800/1000mm
31.5/39.4in
500mm
19.7in
12
34
00-63-030 | DOC-0016143 Rev C | 11-2019
RECESSED MOUNTING
E
250mm
9.8in
500mm
19.7in
800/1000mm
31.5/39.4in

8/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
Perform nearby soil compaction, preferably
with a mechanical vibration compacter.
Check the correct vertical alignment of the pole.
Pole should be oriented in a way that performing
any kind of maintenace is easy and safe.
56
00-63-030 | DOC-0016143 Rev C | 11-2019
RECESSED MOUNTING

9/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
00-63-030 | DOC-0016143 Rev C | 11-2019
56
4
1 x SCR Tri
Head DIN 22424 C
6
The lock plate has to be tightened
to the nut to rotate.
F23
1
1 x M8
SCR Tri Head
DIN 22424 C
9 N.m
6.6 lb.ft +1
-0
6
OPENING - CLOSING POLE DOORS
KEY
KEY
+1
-0
9 N.m
6.6 lb.ft +1
-0
+1
-0
9 N.m
6.6 lb.ft +0.7
-0
+1
-0
9 N.m
6.6 lb.ft +0.7
-0
+1
-0

10/14
Copyright © Schréder S.A. 2018 - Executive Publisher: Stéphane Halleux - Schréder International Services sa - B-4000 Liége, Rue de Mons 3 (Belgium) - The information, descriptions and illustrations herein are only of an indicative nature and subject to changes without notice.
www.schreder.com
00-63-030 | DOC-0016143 Rev C | 11-2019
C-RAIL MOUNTING
Max 2x C-rail for the same door
b
a
1
23
1 x M8
4
1 x M8
4
4
G
5 N.m
3.7 lb.ft +1
-0
+1
-0
5 N.m
3.7 lb.ft +1
-0
+1
-0
Indice

















