Scientific SM6027A Manuale utente

User Manual
DC Bias Current Source
SM6027A

Scientific
User Manual SM6027A 2/31
Copyright © Scientific All rights reserved.
This instrument contains proprietary information, no part of this manual may be photocopied,
reproduced or translated without any prior written consent.
Information in this manual supersede all corresponding previous released material.
Scientific continues to improve products and reserves rights to amend part or all of the
specifications, procedures, equipment at any time without notice.
Rev 1.0/ 0421
Scientific Mes-Technik Pvt. Ltd.,
B-14 Industrial Estate, Pologround,
Indore- 452015 (India)
Tel : 0731-2422330/31/32/33
Fax : 0731-2422334,561641
Website: www.scientificindia.com

Scientific
User Manual SM6027A 3/31
Table of Contents
Chapter 1 General Information ...................................................................................5
1.1 Introduction...................................................................................................5
1.2 Specification .................................................................................................5
1.2.1 Current Accuracy ..........................................................................................5
1.2.2 Display .........................................................................................................5
1.2.3 Control.......................................................................................................... 5
1.2.4 Frequency Response ...................................................................................5
1.2.5 Driver............................................................................................................5
1.2.6 Interface .......................................................................................................6
1.3 Main Functions ............................................................................................6
1.4 Others ..........................................................................................................6
1.4.1 Warm-up.......................................................................................................6
1.4.2 Working Time ...............................................................................................6
1.4.3 Power Supply................................................................................................6
1.4.4 Environment .................................................................................................7
1.4.5 Precautions for usage...................................................................................7
1.4.6 Dimensions...................................................................................................7
1.4.7 Weight .........................................................................................................7
1.4.8 Safety ...........................................................................................................7
Chapter 2 Installation ..................................................................................................9
2.1 Accessories .................................................................................................9
2.1.1 Test Fixture ..................................................................................................9
2.2 Front Panel Description ................................................................................10
Chapter 3 Basic Operations ........................................................................................12
3.1 Instruction of main interface .......................................................................... 12
3.1.1 Current Display ............................................................................................. 12
3.1.2 Current Climbing Progress bar...................................................................... 12
3.1.3 Host & Slave Current Display........................................................................13
3.2 Instruction of Setting Interface ......................................................................13
3.2.1 Parameter Setting.........................................................................................14
3.2.2 List Setting ...................................................................................................15
3.3 System and Tool Testing ..............................................................................16
3.3.1 System testing ..............................................................................................16
3.3.2 System Tool .................................................................................................18
3.4 Instruction of Instrument Output....................................................................20
3.4.1 Current Output..............................................................................................20

Scientific
User Manual SM6027A 4/31
3.4.2 Stop Current Output .....................................................................................20
3.4.3 Single and Steps Output ..............................................................................20
Chapter 4 Command ...................................................................................................21
4.1 SM6027 RS232 Instructions .........................................................................21
4.2 SCPI Command ...........................................................................................21
4.2.1 General Command Set ................................................................................21
4.2.2 Parameter Sub-System command ................................................................22
4.2.3 State Sub-System Command .......................................................................24
4.2.4 System Sub-System Command ....................................................................26
4.2.5 Working Sub-System Command...................................................................28
4.2.6 Other Command ...........................................................................................28
Chapter 5 Service & Maintenance...............................................................................30
Chapter 6 Warranty .....................................................................................................31

Scientific
User Manual SM6027A 5/31
Chapter 1 General Information
1.1 Introduction
SM6027A DC Bias Current Source adopts high-performance MPU and can provide a
constant current range from 0A to 20A. The maximum current output can reach 0-120A
by connecting the slave. SM6027A can be used with Scientific LCR meters. It is
suitable for the AC/DC superposition test of magnetic inductors and provides the
convenient and practical magnetization current source for the characteristic analysis
of magnetic materials.
The instrument can accept real-time modified current at work and respond
immediately.
It adopts a new generation of AC-DC superimposed test principle to adapt to high-
precision and high-frequency test needs.
The instrument has a new design-friendly graphical operation interface and offers a
variety of control modes: manual key control, foot switch control and remote command
control.
1.2 Specification
1.2.1 Current Accuracy
The main machine: 0.000mA~20.0A 1A/5A/20A three current gears;
Up to 5 slaves can be connected, the output current range is 0.000mA ~ 120.0A.
1.2.2 Display
480 × 800 16: 9 24bit true color TFT LCD
1.2.3 Control
Physical keys: START / STOP button to control the start or close of the current output;
Foot switch: two kinds of foot mode to control the start or close of the current output;
RS232: remote control can be performed by commands.
1.2.4 Frequency response
0Hz ~ 2MHz
1.2.5 Driver
Output voltage: 7.5Vmax
The maximum allowable DC resistance of the DUT: Rmax= (Ω);

Scientific
User Manual SM6027A 6/31
The maximum allowable inductance of DUT: Lmax= (mH)
The maximum allowable time of open circuit, overload, overheating or unbalance:
automatic protection <1ms;
The smallest step of sweep:
I ≦1A: 5mA
I ≦5A: 25mA
I ≦120A: 100mA
1.2.6 Interface
SM6027A is equipped with SlaverLink interface, RS232C interface and USB Device
interface.
SM6027A can be connected directly with the Company's L-Meter or LCR Bridge and
can be controlled by some L-Meter or LCR Bridge. It can be controlled by all upper
computers with serial port (the control instruction set must follow the SCPI instruction
set provided by this manual).
1.3 Main Functions
•
Only capable of forward current output. If directional current is needed, please
change the connection direction between DUT and the output end.
•
Display the real-time working state of the main machine and the slaver.
•
With two foot-control mode, strong adaptability.
•
Provide SCPI command
•
With user-friendly graphical interface, can quickly indicate the working status of
the instrument, convenient and efficient control.
•
Provide English and Chinese operation interface.
1.4 Others
1.4.1
Warm-up
Please warm-up the machine minimum for 30 minutes before using it.
1.4.2
Working Time
It is better not to load large current continuously for a long time.
1.4.3
Power Supply
Voltage: AC220/110V (1±10%)

Scientific
User Manual SM6027A 7/31
Frequency: 50/60Hz (1±5%)
Range: ≤600VA
1.4.4 Environment
Temperature:
•
Normal Working: 0~55℃
•
Reference Working: 23±5℃
•
Storage Environment: 0~55℃
Humidity:
•
Normal Working: <90%RH
•
Reference Working: <80%RH
•
Storage Environment: ≤93RH
1.4.5 Precautions for Usage
•
Please do not use the tester in dusty, vibrating, direct sunlight and corrosive gases
and other adverse environments.
•
When the instrument is not used for a long time, please put it in the original box or
similar box and stored in a ventilated room with temperature of 5℃~40℃and
relative humidity less than 85% RH. Do not store the tester in a corrosive
atmosphere containing harmful impurities and should avoid direct sunlight.
•
The instrument has been carefully designed to reduce clutter due to AC power
input. However, it should still be used under low noise conditions. If that is
inevitable, please install the power filter.
1.4.6 Dimension
W*H*D: 430×185×473 (mm3)
1.4.7 Weight
18kg
1.4.8 Safety
This tester is a Class I safe equipment.
1.4.8.1 Insulation resistance
In the reference working conditions, the insulation resistance between the power

Scientific
User Manual SM6027A 8/31
terminals and the shell is not less than 50M.
In hot and humid transport conditions, the insulation resistance between the power
terminals and the shell is not less than 2M .
1.4.8.2 Dielectric strength
In the reference working conditions, the power terminal and the shell can withstand for
one minute with no breakdown and flashover phenomenon of 1.5kV rated voltage and
50Hz frequency of AC voltage.
1.4.8.3 Leakage current
The leakage current is not greater than 3.5mA.

Scientific
User Manual SM6027A 9/31
Chapter 2 Installation
2.1 Accessories
2.1.1 Test Fixture
The standard test fixture is SMA6027-01

Scientific
User Manual SM6027A 10/31
2.2 Front Panel Description
1) Power Switch
Press down to power on, push out to power off.
2) Start Button To start output
3) Stop Button To stop output
4) DC Bias LED
When the instrument starts to output, the output indicator lights up.
5) Number Keys
Used to input numbers
6) Output Port
Current is output from this port.
Indice
Altri manuali Scientific Alimentazione elettrica

Scientific
Scientific DCX 400W Series Manuale utente

Scientific
Scientific PSD3205X Manuale utente

Scientific
Scientific PSA3200 Manuale utente

Scientific
Scientific PSD3203 Manuale utente

Scientific
Scientific PS1600 Series Manuale utente

Scientific
Scientific PSD3205 Manuale utente

Scientific
Scientific PSD3304 Manuale utente

Scientific
Scientific PSD4032A Manuale utente

Scientific
Scientific PS3200 Series Manuale utente

Scientific
Scientific ACPS Series Manuale utente